SearcharxivSearch

arXiv subjects

A. Rybnikov

Publications and source records attributed to A. Rybnikov.

5 recordsLinked to original sources

Burn-in Test and Thermal Performance Evaluation of Silicon Photomultipliers for the JUNO-TAO Experiment

This study evaluates more than 4,000 tiles made of Hamamatsu visual-sensitive silicon photomultipier (SiPM), each with dimensions of 5 $\times$ 5 cm$^2$, intended for the central detector of the Taishan Anti-neutrino Observatory (TAO), a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO) aimed at measuring the reactor anti-neutrino energy spectrum with unprecedented energy resolution. All SiPM tiles underwent a room temperature burn-in test in the dark for two weeks, while cryogenic testing analyzed the thermal dependence of parameters for some sampled SiPMs. Results from these comprehensive tests provide crucial insights into the long-term performance and stability of the 10 square meters of SiPMs operating at -50°C to detect scintillation photons in the TAO detector. Despite some anomalies awaiting further inspection, all SiPMs successfully passed the burn-in test over two weeks at room temperature, which is equivalent to 6.7 years at -50°C. Results are also used to guide optimal SiPM selection, configuration, and operation, ensuring reliability and sustainability in reactor neutrino measurements. This work also provides insights for a rapid and robust quality assessment in future experiments that employ large-scale SiPMs as detection systems.

physics.ins-det

Performance of the Mass Testing Setup for Arrays of Silicon Photomultipliers in the TAO Experiment

Modern neutrino physics detectors often employ thousands, and sometimes even hundreds of thousands, of Silicon Photomultipliers (SiPMs). The TAO experiment is a notable example that utilizes a spherical scintillator barrel with a diameter of 1.8 meters, housing approximately 130,000 SiPMs organized into 4,100 tiles. Each tile with size of 5x5cm^2 consists of a 32-SiPM array functioning as a single detector unit. To achieve an unparalleled energy resolution of 2% at 1 MeV within this volume, the SiPMs must possess cutting-edge parameters, including a photon detection efficiency (PDE) exceeding 50%, cross-talk of approximately 10%, and an extremely low dark count rate (DCR) below 50Hz/mm^2. Maintaining the setup at a negative temperature of -50C is necessary to achieve the desired DCR. This article presents the setup and methods employed to individually characterize the mass of SiPMs across all 4,100 tiles at the specified negative temperature.

physics.ins-det

Study of Silicon Photomultiplier External Cross-Talk

Optical cross-talk is a critical characteristic of Silicon Photomultipliers (SiPMs) and represents a significant source of the excess noise factor, exerting a substantial influence on detector performance. During the avalanche process of SiPMs, photons generated can give rise to both internal cross-talk within the same SiPM and external cross-talk when photons escape from one SiPM and trigger avalanches in others. In scenarios where SiPMs are arranged in a compact configuration and positioned facing each other, the external cross-talk could even dominate the cross-talk phenomenon. This paper investigates two distinct methods for measuring external cross-talk: the counting method, which involves operating SiPMs face-to-face and measuring their coincident signals, and the reflection method, which employs a highly reflective film attached to the surface of the SiPMs. External cross-talk measurements have been conducted on several types of SiPMs, including Vacuum Ultra-Violet (VUV) sensitive SiPMs that Fondazione Bruno Kessler (FBK) and Hamamatsu Photonics Inc (HPK) produced for nEXO as well as visible-sensitive SiPMs provided by FBK, HPK and SensL Technologies Ltd (SenSL) for JUNO-TAO. The results reveal a significant presence of external cross-talk in all tested SiPMs, with HPK's SiPMs exhibiting a dominant external cross-talk component due to the implementation of optical trenches that effectively suppress internal cross-talk. Furthermore, we found that the number of fired pixels resulting from internal cross-talk can be described by combining Geometric and Borel models for all tested SiPMs, while the external cross-talk can be predicted using a pure Borel model. These distinct probability distributions lead to different excess noise factors, thereby impacting the detector performance in varying ways.

physics.ins-det

Study of Silicon Photomultiplier Performance at Different Temperatures

Decreasing the operation temperature of a Silicon Photo-Multiplier (SiPM) leads to a drop in its dark noise. Some experiments consider cold temperatures as an option for low noise applications of SiPM. One of those is the TAO detector, which requires operation at $T\approx -50~^\circ$C. A significant dependence of the Photon Detection Efficiency (PDE) of a SiPM on different temperatures was reported with a drastic drop around this temperature. In this paper, we present studies of performance for two samples of SiPMs from Hamamatsu and AdvanSID(FBK) companies in a broad temperature range. No significant difference for the PDE was observed.

physics.ins-det

Optimization of the light intensity for Photodetectors calibration

In this article we present an evaluation of the uncertainty in the average number of photoelectrons, which is important for the calibration of photodetectors. We show that the statistical uncertainty depends on light intensity, and on the method of evaluation. For some cases there is optimal light intensity where the accuracy reaches its optimal value with fixed statistics. A method of photoelectron evaluation based on the extraction of pedestal's (zero) probability gives the best accuracy at approximately 1.6 photoelectrons for a noiseless photodetector and shifts out to higher values with the presence of noise. In the general case, estimation of the average number of photoelectrons is biased and might need special consideration.

physics.ins-det