arXiv · 2005.10665
Study of Silicon Photomultiplier Performance at Different Temperatures
Abstract
Decreasing the operation temperature of a Silicon Photo-Multiplier (SiPM) leads to a drop in its dark noise. Some experiments consider cold temperatures as an option for low noise applications of SiPM. One of those is the TAO detector, which requires operation at $T\approx -50~^\circ$C. A significant dependence of the Photon Detection Efficiency (PDE) of a SiPM on different temperatures was reported with a drastic drop around this temperature. In this paper, we present studies of performance for two samples of SiPMs from Hamamatsu and AdvanSID(FBK) companies in a broad temperature range. No significant difference for the PDE was observed.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
N. Anfimov, D. Fedoseev, A. Rybnikov, A. Selyunin, S. Sokolov, A. Sotnikov. 2020-05-21. Study of Silicon Photomultiplier Performance at Different Temperatures. https://doi.org/10.1016/j.nima.2021.165162
Cite the original work for its findings. Save a collection to share your selection of sources.