Distillation of Liquid Xenon to Remove Krypton

A high performance distillation system to remove krypton from xenon was constructed, and a purity level of Kr/Xe = $\sim 3 \times 10^{-12}$ was achieved. This development is crucial in facilitating high sensitivity low background experiments such as the search for dark matter in the universe.

physics.ins-det↗

Scintillation yield of liquid xenon at room temperature

The intensity of scintillation light emission from liquid xenon at room temperature was measured. The scintillation light yield at 1 deg. was measured to be 0.64 +/- 0.02 (stat.) +/- 0.06 (sys.) of that at -100 deg. Using the reported light yield at -100 deg. (46 photons/keV), the measured light yield at 1 deg. corresponds to 29 photons/keV. This result shows that liquid xenon scintillator gives high light yield even at room temperature.

physics.ins-det↗

Search for Supernova Neutrino Bursts at Super-Kamiokande

The result of a search for neutrino bursts from supernova explosions using the Super-Kamiokande detector is reported. Super-Kamiokande is sensitive to core-collapse supernova explosions via observation of their neutrino emissions. The expected number of events comprising such a burst is ~10^4 and the average energy of the neutrinos is in few tens of MeV range in the case of a core-collapse supernova explosion at the typical distance in our galaxy (10 kiloparsecs); this large signal means that the detection efficiency anywhere within our galaxy and well past the Magellanic Clouds is 100%. We examined a data set which was taken from May, 1996 to July, 2001 and from December, 2002 to October, 2005 corresponding to 2589.2 live days. However, there is no evidence of such a supernova explosion during the data-taking period. The 90% C.L. upper limit on the rate of core-collapse supernova explosions out to distances of 100 kiloparsecs is found to be 0.32 SN/year.

astro-ph↗

Development of Gaseous Tracking Devices for the Search of WIMPs

The Time Projection Chamber (TPC) has been recognized as a potentially powerful detector for the search of WIMPs by measuring the directions of nuclear recoils, in which the most convincing signature of WIMPs, caused by the Earth's motion around the Galaxy, appears. We report on the first results of a performance study of the neutron exposure of our prototype micro-TPC with Ar-C$_2$H$_6$ (90:10) and CF$_4$ gas of 150 Torr.

astro-ph↗

Studies of the performance of different front-end systems for flat-panel multi-anode PMTs with CsI(Tl) scintillator arrays

We have studied the performance of two different types of front-end systems for our gamma camera based on Hamamatsu H8500 (flat-panel 64 channels multi-anode PSPMT) with a CsI(Tl) scintillator array. The array consists of 64 pixels of $6\times6\times20{\rm mm}^3$ which corresponds to the anode pixels of H8500. One of the system is based on commercial ASIC chips in order to readout every anode. The others are based on resistive charge divider network between anodes to reduce readout channels. In both systems, each pixel (6mm) was clearly resolved by flood field irradiation of $^{137}$Cs. We also investigated the energy resolution of these systems and showed the performance of the cascade connection of resistive network between some PMTs for large area detectors.

physics.ins-det↗

Development of an advanced Compton camera with gaseous TPC and scintillator

A prototype of the MeV gamma-ray imaging camera based on the full reconstruction of the Compton process has been developed. This camera consists of a micro-TPC that is a gaseous Time Projection Chamber (TPC) and scintillation cameras. With the information of the recoil electrons and the scattered gamma-rays, this camera detects the energy and incident direction of each incident gamma-ray. We developed a prototype of the MeV gamma-ray camera with a micro-TPC and a NaI(Tl) scintillator, and succeeded in reconstructing the gamma-rays from 0.3 MeV to 1.3 MeV. Measured angular resolutions of ARM (Angular Resolution Measure) and SPD (Scatter Plane Deviation) for 356 keV gamma-rays were $18^\circ$ and $35^\circ$, respectively.

astro-ph↗

Development of an ASD IC for the Micro Pixel Chamber

A new amplifier-shaper-discriminator (ASD) chip was designed and manufactured for the Micro Pixel Chamber ($μ$-PIC). The design of this ASD IC is based on the ASD IC (TGC-ASD) for the Thin Gap Chamber in the LHC Atlas Experiment. The decay time constant of the preamplifier is 5-times longer than that of the TGC-ASD, and some other modifications have been made in order to improve the signal-to-noise ratio of the $μ$-PIC. The ASD IC uses SONY Analog Master Slice bipolar technology. The IC contains 4 channels in a QFP48 package. The decay time constant of the preamplifier is 80 ns and its gain is approximately 0.8 V/pC. The output from the preamplifier is received by a shaper (main-amplifier) with a gain of 7. A baseline restoration circuit is incorporated in the main-amplifier, and the current used for the baseline restoration is 5-times smaller than that of the TGC-ASD. The threshold voltage for the discriminator section is common to the 4 channels and their digital output level is LVDS-compatible. The ASD IC also has an analog output of the preamplifier. The equivalent noise charge at the input capacitance of 50 pF is around 2000 electrons. The power dissipation with LVDS outputs (100 $Ω$ load) is 57 mW/ch. Using this ASD, the analog output voltage from the signal of the $μ$-PIC is about 2-times higher than the case of using the TGC-ASD.As a consequence, the MIPs tracking performance of the Time Projection Chamber (TPC) with the $μ$-PIC was improved.The performance of the ASD IC and an improved tracking performance of the TPC are reported.

physics.ins-det↗

Limits on the WIMP-Nucleon Coupling Coefficients from Dark Matter Search Experiment with NaF Bolometer

We have performed the underground dark matter search experiment with a sodium fl uoride (NaF) bolometer array from 2002 through 2003 at Kamioka Observatory (2700 m.w.e.). The bolometer array consists of eight NaF absorbers with a total mass of 176 g, and sensitive NTD germanium thermistors glued to each of them. This experiment aims for the direct detection of weakly interacting massive part icles (WIMPs) via spin-dependent interaction. With an exposure of 3.38 kg days, we derived the limits on the WIMP-n ucleon coupling coefficients, a_p and a_n. These limits confirmed and tightened those derived from our previous results wit h the lithium fluoride (LiF) bolometer. Our results excluded the parameter space complementary to the results obtained b y NaI detectors of UKDMC experiment.

astro-ph↗

First results from dark matter search experiment with LiF bolometer at Kamioka Underground Laboratory

Tokyo group has performed first underground dark matter search experiment in 2001 through 2002 at Kamioka Observatory(2700m.w.e). The detector is eight LiF bolometers with total mass 168g aiming for the direct detection of WIMPs via spin-dependent interaction. With a total exposure of 4.1 kg days, we derived the limits in the a_p-a_n (WIMP-nucleon couplings) plane and excluded a large part of the parameter space allowed by the UKDMC experiment.

astro-ph↗