SearcharxivSearch

arXiv · physics/0403065

Development of an ASD IC for the Micro Pixel Chamber

Abstract

A new amplifier-shaper-discriminator (ASD) chip was designed and manufactured for the Micro Pixel Chamber ($μ$-PIC). The design of this ASD IC is based on the ASD IC (TGC-ASD) for the Thin Gap Chamber in the LHC Atlas Experiment. The decay time constant of the preamplifier is 5-times longer than that of the TGC-ASD, and some other modifications have been made in order to improve the signal-to-noise ratio of the $μ$-PIC. The ASD IC uses SONY Analog Master Slice bipolar technology. The IC contains 4 channels in a QFP48 package. The decay time constant of the preamplifier is 80 ns and its gain is approximately 0.8 V/pC. The output from the preamplifier is received by a shaper (main-amplifier) with a gain of 7. A baseline restoration circuit is incorporated in the main-amplifier, and the current used for the baseline restoration is 5-times smaller than that of the TGC-ASD. The threshold voltage for the discriminator section is common to the 4 channels and their digital output level is LVDS-compatible. The ASD IC also has an analog output of the preamplifier. The equivalent noise charge at the input capacitance of 50 pF is around 2000 electrons. The power dissipation with LVDS outputs (100 $Ω$ load) is 57 mW/ch. Using this ASD, the analog output voltage from the signal of the $μ$-PIC is about 2-times higher than the case of using the TGC-ASD.As a consequence, the MIPs tracking performance of the Time Projection Chamber (TPC) with the $μ$-PIC was improved.The performance of the ASD IC and an improved tracking performance of the TPC are reported.

Explore related subjects

Keep this discovery

BibTeXRIS

R. Orito, O. Sasaki, H. Kubo, K. Miuchi, T. Nagayoshi, Y. Okada, A. Takada, A. Takeda, T. Tanimori, M. Ueno. 2004-03-11. Development of an ASD IC for the Micro Pixel Chamber. https://doi.org/10.1109/tns.2004.832673

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det