Searcharxiv⌕ Search

arXiv subjects

A. Weber

Publications and source records attributed to A. Weber.

At least 37 records · Page 2Linked to original sources

Performance of the large scale HV-CMOS pixel sensor MuPix8

The Mu3e experiment is searching for the charged lepton flavour violating decay $ μ^+\rightarrow e^+ e^- e^+ $, aiming for an ultimate sensitivity of one in $10^{16}$ decays. In an environment of up to $10^9$ muon decays per second the detector needs to provide precise vertex, time and momentum information to suppress accidental and physics background. The detector consists of cylindrical layers of $50\, μ\text{m}$ thin High Voltage Monolithic Active Pixel Sensors (HV-MAPS) placed in a $1\,\text{T}$ magnetic field. The measurement of the trajectories of the decay particles allows for a precise vertex and momentum reconstruction. Additional layers of fast scintillating fibre and tile detectors provide sub-nanosecond time resolution. The MuPix8 chip is the first large scale prototype, proving the scalability of the HV-MAPS technology. It is produced in the AMS aH18 $180\, \text{nm}$ HV-CMOS process. It consists of three sub-matrices, each providing an untriggered datastream of more than $10\,\text{MHits}/\text{s}$. The latest results from laboratory and testbeam characterisation are presented, showing an excellent performance with efficiencies $>99.6\,\text{\%}$ and a time resolution better than $10\, \text{ns}$ achieved with time walk correction.

physics.ins-det↗

The influence of Fermi motion on the comparison of the polarization transfer to a proton in elastic $\vec ep$ and quasi-elastic $\vec eA$ scattering

A comparison between polarization-transfer to a bound proton in quasi-free kinematics by the A$(\vec{e},e'\vec p)$ knockout reaction and that in elastic scattering off a free proton can provide information on the characteristics of the bound proton. In the past the reported measurements have been compared to those of a free proton with zero initial momentum. We introduce, for the first time, expressions for the polarization-transfer components when the proton is initially in motion and compare them to the $^2$H data measured at the Mainz Microtron (MAMI). We show the ratios of the transverse ($P_x$) and longitudinal ($P_z$) components of the polarization transfer in $^2\textrm{H}(\vec{e},e'\vec p)\textrm{n}$, to those of elastic scattering off a "moving proton", assuming the proton's initial (Fermi) momentum equals the negative missing momentum in the measured reaction. We found that the correction due to the proton motion is up to 20\% at high missing momentum. However the effect on the double ratio $\frac{(P_x/P_z)^A}{(P_x/P_z)^{^1\!\textrm{H}}}$ is largely canceled out, as shown for both $^2$H and $^{12}$C data. This implies that the kinematics is not the primary cause for the deviations between quasi-elastic and elastic scattering reported previously.

nucl-ex↗

Identifying the Parametric Occurrence of Multiple Steady States for some Biological Networks

We consider a problem from biological network analysis of determining regions in a parameter space over which there are multiple steady states for positive real values of variables and parameters. We describe multiple approaches to address the problem using tools from Symbolic Computation. We describe how progress was made to achieve semi-algebraic descriptions of the multistationarity regions of parameter space, and compare symbolic results to numerical methods. The biological networks studied are models of the mitogen-activated protein kinases (MAPK) network which has already consumed considerable effort using special insights into its structure of corresponding models. Our main example is a model with 11 equations in 11 variables and 19 parameters, 3 of which are of interest for symbolic treatment. The model also imposes positivity conditions on all variables and parameters. We apply combinations of symbolic computation methods designed for mixed equality/inequality systems, specifically virtual substitution, lazy real triangularization and cylindrical algebraic decomposition, as well as a simplification technique adapted from Gaussian elimination and graph theory. We are able to determine multistationarity of our main example over a 2-dimensional parameter space. We also study a second MAPK model and a symbolic grid sampling technique which can locate such regions in 3-dimensional parameter space.

cs.SC↗

Virtual Compton Scattering measurements in the nucleon resonance region

We report on new measurements of the electric Generalized Polarizability (GP) of the proton $α_E$ in a kinematic region where a puzzling dependence on momentum transfer has been observed, and we have found that $α_E = (5.3 \pm 0.6_{stat} \pm 1.3_{sys})~10^{-4} fm^3$ at $Q^2=0.20~(GeV/c)^2$. The new measurements, when considered along with the rest of the world data, suggest that $α_E$ can be described by either a local plateau or by an enhancement in the region $Q^2=0.20~(GeV/c)^2$ to $0.33~(GeV/c)^2$. The experiment also provides the first measurement of the Coulomb quadrupole amplitude in the $N \rightarrow Δ$ transition through the exploration of the $p(e,e'p)γ$ reaction. The new measurement gives $CMR = (-4.4 \pm 0.8_{stat} \pm 0.6_{sys})~\%$ at $Q^2=0.20~(GeV/c)^2$ and is consistent with the results from the pion electroproduction world data. It has been obtained using a completely different extraction method, and therefore represents a strong validation test of the world data model uncertainties.

nucl-ex↗

Development of a Quality Assurance Process for the SoLid Experiment

The SoLid experiment has been designed to search for an oscillation pattern induced by a light sterile neutrino state, utilising the BR2 reactor of SCK$\bullet$CEN, in Belgium. The detector leverages a new hybrid technology, utilising two distinct scintillators in a cubic array, creating a highly segmented detector volume. A combination of 5 cm cubic polyvinyltoluene cells, with $^6$LiF:ZnS(Ag) sheets on two faces of each cube, facilitate reconstruction of the neutrino signals. % The polyvinyltoluene scintillator is used as an $\overlineν_e$ target for the inverse beta decay of ($\overlineν_e + p \rightarrow e^{+}+n$), with the $^6$LiF:ZnS(Ag) sheets used for associated neutron detection. Scintillation signals are read out by a network of wavelength shifting fibres connected to multipixel photon counters. Whilst the high granularity provides a powerful toolset to discriminate backgrounds; by itself the segmentation also represents a challenge in terms of homogeneity and calibration, for a consistent detector response. The search for this light sterile neutrino implies a sensitivity to distortions of around $\mathcal{O}$(10)\% in the energy spectrum of reactor $\overlineν_e$. Hence, a very good neutron detection efficiency, light yield and homogeneous detector response are critical for data validation. The minimal requirements for the SoLid physics program are a light yield and a neutron detection efficiency larger than 40 PA/MeV/cube and 50 \% respectively. In order to guarantee these minimal requirements, the collaboration developed a rigorous quality assurance process for all 12800 cubic cells of the detector. To carry out the quality assurance process, an automated calibration system called CALIPSO was designed and constructed.

physics.ins-det↗

Measurement of final-state correlations in neutrino muon-proton mesonless production on hydrocarbon at $\langle E_ν\rangle=3$ GeV

Final-state kinematic imbalances are measured in mesonless production of $ν_μ+ A \to μ^- + p + X$ in the MINERvA tracker. Initial- and final-state nuclear effects are probed using the direction of the $μ^-$-p transverse momentum imbalance and the initial-state momentum of the struck neutron. Differential cross sections are compared to predictions based on current approaches to medium modeling. These models under-predict the cross section at intermediate intranuclear momentum transfers that generally exceed the Fermi momenta. As neutrino interaction models need to correctly incorporate the effect of the nucleus in order to predict neutrino energy resolution in oscillation experiments, this result points to a region of phase space where additional cross section strength is needed in current models, and demonstrates a new technique that would be suitable for use in fine grained liquid argon detectors where the effect of the nucleus may be even larger.

hep-ex↗

Optimisation of the scintillation light collection and uniformity for the SoLid experiment

This paper presents a comprehensive optimisation study to maximise the light collection efficiency of scintillating cube elements used in the SoLid detector. Very short baseline reactor experiments, like SoLid, look for active to sterile neutrino oscillation signatures in the anti-neutrino energy spectrum as a function of the distance to the core and energy. Performing a precise search requires high light yield of the scintillating elements and uniformity of the response in the detector volume. The SoLid experiment uses an innovative hybrid technology with two different scintillators: polyvinyltoluene scintillator cubes and $^6$LiF:ZnS(Ag) screens. A precision test bench based on a $^{207}$Bi calibration source has been developed to study improvements on the energy resolution and uniformity of the prompt scintillation signal of antineutrino interactions. A trigger system selecting the 1~MeV conversion electrons provides a Gaussian energy peak and allows for precise comparisons of the different detector configurations that were considered to improve the SoLid detector light collection. The light collection efficiency is influenced by the choice of wrapping material, the position of the $^6$LiF:ZnS(Ag) screen, the type of fibre, the number of optical fibres and the type of mirror at the end of the fibre. This study shows that large gains in light collection efficiency are possible compared to the SoLid SM1 prototype. The light yield for the SoLid detector is expected to be at least 52$\pm$2 photo-avalanches per MeV per cube, with a relative non-uniformity of 6 %, demonstrating that the required energy resolution of at least 14 % at 1 MeV can be achieved.

physics.ins-det↗

Beyond 100 nm Resolution in 3D Laser Lithography: Post Processing Solutions

Laser polymerization has emerged as a direct writing technique allowing the fabrication of complex 3D structures with microscale resolution. The technique provides rapid prototyping capabilities for a broad range of applications, but to meet the growing interest in 3D nanoscale structures the resolution limits need to be pushed beyond the 100 nm benchmark, which is challenging in practical implementations. As a possible path towards this goal, a post processing of laser polymerized structures is presented. Precise control of the cross-sectional dimensions of structural elements as well as tuning of an overall size of the entire 3D structure was achieved by combining isotropic plasma etching and pyrolysis. The smallest obtainable feature sizes are mostly limited by the mechanical properties of the polymerized resist and the geometry of 3D structure. Thus the demonstrated post processing steps open new avenues to explore free form 3D structures at the nanoscale.

physics.app-ph↗

Performance of a full scale prototype detector at the BR2 reactor for the SoLid experiment

The SoLid collaboration has developed a new detector technology to detect electron anti-neutrinos at close proximity to the Belgian BR2 reactor at surface level. A 288$\,$kg prototype detector was deployed in 2015 and collected data during the operational period of the reactor and during reactor shut-down. Dedicated calibration campaigns were also performed with gamma and neutron sources. This paper describes the construction of the prototype detector with a high control on its proton content and the stability of its operation over a period of several months after deployment at the BR2 reactor site. All detector cells provide sufficient light yields to achieve a target energy resolution of better than 20%/$\sqrt{E(MeV)}$. The capability of the detector to track muons is exploited to equalize the light response of a large number of channels to a precision of 3% and to demonstrate the stability of the energy scale over time. Particle identification based on pulse-shape discrimination is demonstrated with calibration sources. Despite a lower neutron detection efficiency due to triggering constraints, the main backgrounds at the reactor site were determined and taken into account in the shielding strategy for the main experiment. The results obtained with this prototype proved essential in the design optimization of the final detector. This paper is dedicated to our SCK$\cdot$CEN colleague, Edgar Koonen, who passed away unexpectedly in 2017. Edgar was part of the SoLid collaboration since its inception and his efforts were vital to get the experiment started. He will be duly missed.

physics.ins-det↗

Measurement of polarization-transfer to bound protons in carbon and its virtuality dependence

We measured the ratio $P_{x}/P_{z}$ of the transverse to longitudinal components of polarization transferred from electrons to bound protons in $^{12}\mathrm{C}$ by the $^{12}\mathrm{C}(\vec{e},e'\vec{p})$ process at the Mainz Microtron (MAMI). We observed consistent deviations from unity of this ratio normalized to the free-proton ratio, $(P_{x}/P_{z})_{^{12}\mathrm{C}}/(P_{x}/P_{z})_{^{1}\mathrm{H}}$, for both $s$- and $p$-shell knocked out protons, even though they are embedded in averaged local densities that differ by about a factor of two. The dependence of the double ratio on proton virtuality is similar to the one for knocked out protons from $^{2}\mathrm{H}$ and $^{4}\mathrm{He}$, suggesting a universal behavior. It further implies no dependence on average local nuclear density.

nucl-ex↗

Components of polarization-transfer to a bound proton in a deuteron measured by quasi-elastic electron scattering

We report the first measurements of the transverse ($P_{x}$ and $P_{y}$) and longitudinal ($P_{z}$) components of the polarization transfer to a bound proton in the deuteron via the $^{2}\mathrm{H}(\vec{e},e'\vec{p})$ reaction, over a wide range of missing momentum. A precise determination of the electron beam polarization reduces the systematic uncertainties on the individual components, to a level that enables a detailed comparison to a state-of-the-art calculation of the deuteron that uses free-proton electromagnetic form factors. We observe very good agreement between the measured and the calculated $P_{x}/P_{z}$ ratios, but deviations of the individual components. Our results cannot be explained by medium modified electromagnetic form factors. They point to an incomplete description of the nuclear reaction mechanism in the calculation.

nucl-ex↗

A novel segmented-scintillator antineutrino detector

The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator technology. The detector target uses cubes of polyvinyltoluene interleaved with $^6$LiF:ZnS(Ag) phosphor screens to detect the products of the inverse beta decay reaction. A multi-tonne detector system built from these individual cells can provide precise localisation of scintillation signals, making efficient use of the detector volume. Monte Carlo simulations indicate that a neutron capture efficiency of over 70% is achievable with a sufficient number of $^6$LiF:ZnS(Ag) screens per cube and that an appropriate segmentation enables a measurement of the positron energy which is not limited by gamma-ray leakage. First measurements of a single cell indicate that a very good neutron-gamma discrimination and high neutron detection efficiency can be obtained with adequate triggering techniques. The light yield from positron signals has been measured, showing that an energy resolution of 14%/$\sqrt{E({\mathrm{MeV}})}$ is achievable with high uniformity. A preliminary neutrino signal analysis has been developed, using selection criteria for pulse shape, energy, time structure and energy spatial distribution and showing that an antineutrino efficiency of 40% can be achieved. It also shows that the fine segmentation of the detector can be used to significantly decrease both correlated and accidental backgrounds.

physics.ins-det↗

Low energy meson spectrum from a QCD approach based on many-body methods

The TDA and RPA many-body methods are applied to a QCD motivated Hamiltonian in the Coulomb gauge. The gluon effects in the low energy domain are accounted for by the Instantaneous color-Coulomb Interaction between color-charge densities, approximated by the sum of a Coulomb and a confining linear potentials. We use the eigenfunctions of the harmonic oscillator as a basis for the quantization of the quark fields, and discuss how suitable this basis is in various steps of the calculation. We show that the TDA results already reproduce the gross-structure of the light flavored meson states. The pion-like state in the RPA description, which is a highly collective state, is in a better agreement with the experimental value. The results are related to other nonperturbative treatments and compared to experimental data. We discuss the advantages of the present approach.

nucl-th↗

Vertical Beam Polarization at MAMI

For the first time a vertically polarized electron beam has been used for physics experiments at MAMI in the energy range between 180 and 855 MeV. The beam-normal single-spin asymmetry $A_{\mathrm{n}}$, which is a direct probe of higher-order photon exchange beyond the first Born approximation, has been measured in the reaction $^{12}\mathrm C(\vec e,e')^{12}\mathrm C$. Vertical polarization orientation was necessary to measure this asymmetry with the existing experimental setup. In this paper we describe the procedure to orient the electron polarization vector vertically, and the concept of determining both its magnitude and orientation with the available setup. A sophisticated method has been developed to overcome the lack of a polarimeter setup sensitive to the vertical polarization component.

physics.acc-ph↗

A versatile UHV transport and measurement chamber for neutron reflectometry under UHV conditions

We report on a versatile mini ultra-high vacuum (UHV) chamber which is designed to be used on the MAgnetic Reflectometer with high Incident Angle of the Jülich Centre for Neutron Science at Heinz Maier-Leibnitz Zentrum in Garching, Germany. Samples are prepared in the adjacent thin film laboratory by molecular beam epitaxy and moved into the compact chamber for transfer without exposure to ambient air. The chamber is based on DN 40 CF flanges and equipped with sapphire view ports, a small getter pump, and a wobble stick, which serves also as sample holder. Here, we present polarized neutron reflectivity measurements which have been performed on Co thin films at room temperature in UHV and in ambient air in a magnetic field of 200 mT and in the Q-range of 0.18 Å$^{-1}$. The results confirm that the Co film is not contaminated during the polarized neutron reflectivity measurement. Herewith it is demonstrated that the mini UHV transport chamber also works as a measurement chamber which opens new possibilities for polarized neutron measurements under UHV conditions.

physics.ins-det↗

The SoLid anti-neutrino detector's readout system

The SoLid collaboration have developed an intelligent readout system to reduce their 3200 silicon photomultiplier detector's data rate by a factor of 10000 whilst maintaining high efficiency for storing data from anti-neutrino interactions. The system employs an FPGA-level waveform characterisation to trigger on neutron signals. Following a trigger, data from a space time region of interest around the neutron will be read out using the IPbus protocol. In these proceedings the design of the readout system is explained and results showing the performance of a prototype version of the system are presented.

physics.ins-det↗

TITUS: the Tokai Intermediate Tank for the Unoscillated Spectrum

The TITUS, Tokai Intermediate Tank for Unoscillated Spectrum, detector, is a proposed Gd-doped Water Cherenkov tank with a magnetised muon range detector downstream. It is located at J-PARC at about 2 km from the neutrino target and it is proposed as a potential near detector for the Hyper-Kamiokande experiment. Assuming a beam power of 1.3 MW and 27.05 x 10^{21} protons-on-target the sensitivity to CP and mixing parameters achieved by Hyper-Kamiokande with TITUS as a near detector is presented. Also, the potential of the detector for cross sections and Standard Model parameter determination, supernova neutrino and dark matter are shown.

physics.ins-det↗

Optical Characterization of the BICEP3 CMB Polarimeter at the South Pole

BICEP3 is a small-aperture refracting cosmic microwave background (CMB) telescope designed to make sensitive polarization maps in pursuit of a potential B-mode signal from inflationary gravitational waves. It is the latest in the BICEP/Keck Array series of CMB experiments at the South Pole, which has provided the most stringent constraints on inflation to date. For the 2016 observing season, BICEP3 was outfitted with a full suite of 2400 optically coupled detectors operating at 95 GHz. In these proceedings we report on the far field beam performance using calibration data taken during the 2015-2016 summer deployment season in situ with a thermal chopped source. We generate high-fidelity per-detector beam maps, show the array-averaged beam profile, and characterize the differential beam response between co-located, orthogonally polarized detectors which contributes to the leading instrumental systematic in pair differencing experiments. We find that the levels of differential pointing, beamwidth, and ellipticity are similar to or lower than those measured for BICEP2 and Keck Array. The magnitude and distribution of BICEP3's differential beam mismatch - and the level to which temperature-to-polarization leakage may be marginalized over or subtracted in analysis - will inform the design of next-generation CMB experiments with many thousands of detectors.

astro-ph.IM↗