SearcharxivSearch

arXiv subjects

Akira Takenaka

Publications and source records attributed to Akira Takenaka.

5 recordsLinked to original sources

The Radioactive Background of the JUNO Calibration System

The Jiangmen Underground Neutrino Observatory (JUNO) experiment is a reactor antineutrino detector employing 20 kton of ultra-pure liquid scintillator to determine the neutrino mass ordering and to precisely measure oscillation parameters. The total singles background rate from radioactivity is required to be below 10 Hz in the energy range of 0.7-12 MeV within the fiducial volume for reactor neutrino analysis. The calibration system is designed to characterize the detector energy and position responses, while several of its components are located close to the target and may contribute to the background budget. Therefore, extensive material screening and selection are required to construct a low-background calibration system and to ensure that its contribution remains within the design requirements. In this work, a comprehensive study of the radioactive background induced by the calibration system is presented, including material radioactivity measurements using high-purity germanium detectors and neutron activation analysis techniques, detailed Monte Carlo simulations to evaluate the background, and comparisons with in-situ detector data to validate the predictions. In this data analysis, dedicated spatial selection methods are developed to isolate calibration-related contributions and to suppress the liquid scintillator background. The total radioactivity contribution from the calibration system is estimated to be less than 76 mHz, which satisfies the requirement of 200 mHz (2% of the total background budget). The results from in-situ data are found to be consistent with the expectations based on material assay and simulation within uncertainties. These results demonstrate that the calibration-induced background is well understood, in agreement between data and simulation, and negligible for reactor antineutrino measurements in JUNO.

physics.ins-det

Understanding the impact of nuclear effects on proton decay searches with the GiBUU model

Proton decay searches in the next generation of water Cherenkov detectors, such as Hyper-Kamiokande, are expected to probe the $10^{35}$-year lifetime regime where atmospheric neutrino backgrounds and systematic uncertainties begin to play an increasingly important role. In this study, we employ the GiBUU framework and reevaluate the proton decay search sensitivity for the $\textrm{p}\rightarrow\textrm{e}^{+}π^{0}$ channel by incorporating a typical event reconstruction performance in water Cherenkov detectors. Using sophisticated models implemented in GiBUU -- most notably the mean-field potential and Boltzmann transport -- which have been benchmarked against accelerator neutrino scattering data, in particular pion production, we find that the resulting proton decay signal detection efficiency and atmospheric neutrino background rate are comparable to those previously evaluated for the current and near future water Cherenkov experiments using $\textit{ad hoc}$ nuclear models. In addition to pion final-state interactions, we evaluate the impact of differences in the Fermi momentum distribution of nucleons in the nucleus, as a source of systematic uncertainty, on the signal detection efficiency and the expected background event rate. We find that the uncertainty associated with pion final-state interactions is moderate, whereas the choice of Fermi momentum distribution can significantly affect the estimated atmospheric neutrino background rate and constitutes the dominant contribution. Our study provides an independent and complementary characterisation of nuclear effects on proton decay searches and helps to refine sensitivity estimates in the regime where systematic uncertainties become more relevant.

hep-ex

Neutron source-based event reconstruction algorithm in large liquid scintillator detectors

We developed an event reconstruction algorithm, applicable to large liquid scintillator detectors, built primarily upon neutron calibration data. We employ a likelihood method using photon detection time and charge information from individual photomultiplier tubes. Detector response tables in the likelihood function were derived from americium-carbon neutron source events, 2.2~MeV $γ$-ray events from cosmic-ray muon spallation neutrons, and laser calibration events. This algorithm can reconstruct the event position, energy, and also has capability to differentiate particle types for events within the energy range of reactor neutrinos. Using the detector simulation of the Jiangmen Underground Neutrino Observatory (JUNO) experiment as a large liquid scintillator detector example, we demonstrate that the presented reconstruction algorithm has a reconstructed position accuracy within $\pm$4~cm, and a reconstructed energy non-uniformity under 0.5\% throughout the central detector volume. The vertex resolution for positron events at 1~MeV is estimated to be around 9~cm, and the energy resolution is confirmed to be comparable to that in the JUNO official publication. Furthermore, the algorithm can eliminate 80\% (45\%) of $α$-particle (fast-neutron) events while maintaining a positron event selection efficiency of approximately 99\%.

physics.ins-det

Customized calibration sources in the JUNO experiment

We customized a laser calibration system and four radioactive $γ$-ray calibration sources for the Jiangmen Underground Neutrino Observatory (JUNO), a 20-kton liquid scintillator-based neutrino detector. The laser source system was updated to realize the isotropic light emission timing within $\pm0.25$~nsec level and to allow the tuning of the laser intensity covering more than four orders of magnitude. In addition, methods to prepare four different radioactive sources ($^{18}{\rm F}$, $^{40}{\rm K}$, $^{226}{\rm Ra}$, and $^{241}{\rm Am}$), covering energies from O(10)~keV to O(1)~MeV, for the JUNO detector were established in this study. The radioactivity of each source and the risk of impurities leaking into the detector from the source were confirmed to meet the experimental requirements.

physics.ins-det

Simulation Software of the JUNO Experiment

The Jiangmen Underground Neutrino Observatory (JUNO) is a multi-purpose experiment, under construction in southeast China, that is designed to determine the neutrino mass ordering and precisely measure neutrino oscillation parameters. Monte Carlo simulation plays an important role for JUNO detector design, detector commissioning, offline data processing, and physics processing. The JUNO experiment has the world's largest liquid scintillator detector instrumented with many thousands of PMTs. The broad energy range of interest, long lifetime, and the large scale present data processing challenges across all areas. This paper describes the JUNO simulation software, highlighting the challenges of JUNO simulation and solutions to meet these challenges, including such issues as support for time-correlated analysis, event mixing, event correlation and handling the simulation of many millions of optical photons.

hep-ex