The Radioactive Background of the JUNO Calibration System

Abstract

The Jiangmen Underground Neutrino Observatory (JUNO) experiment is a reactor antineutrino detector employing 20 kton of ultra-pure liquid scintillator to determine the neutrino mass ordering and to precisely measure oscillation parameters. The total singles background rate from radioactivity is required to be below 10 Hz in the energy range of 0.7-12 MeV within the fiducial volume for reactor neutrino analysis. The calibration system is designed to characterize the detector energy and position responses, while several of its components are located close to the target and may contribute to the background budget. Therefore, extensive material screening and selection are required to construct a low-background calibration system and to ensure that its contribution remains within the design requirements. In this work, a comprehensive study of the radioactive background induced by the calibration system is presented, including material radioactivity measurements using high-purity germanium detectors and neutron activation analysis techniques, detailed Monte Carlo simulations to evaluate the background, and comparisons with in-situ detector data to validate the predictions. In this data analysis, dedicated spatial selection methods are developed to isolate calibration-related contributions and to suppress the liquid scintillator background. The total radioactivity contribution from the calibration system is estimated to be less than 76 mHz, which satisfies the requirement of 200 mHz (2% of the total background budget). The results from in-situ data are found to be consistent with the expectations based on material assay and simulation within uncertainties. These results demonstrate that the calibration-induced background is well understood, in agreement between data and simulation, and negligible for reactor antineutrino measurements in JUNO.

Explore related subjects

Keep this discovery

BibTeXRIS

Rui Li, Youhui Yun, Zhangming Chen, Junting Huang, Jiaqi Hui, Haojing Lai, Jianglai Liu, Yankai Liu, Yue Meng, Akira Takenaka, Ziqian Xiang, Feiyang Zhang, Ping Zhang, Qingmin Zhang, Tao Zhang, Yuanyuan Zhang. 2026-08-19. The Radioactive Background of the JUNO Calibration System. https://arxiv.org/abs/2608.19051

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det