SearcharxivSearch

arXiv subjects

Alessandro Monfardini

Publications and source records attributed to Alessandro Monfardini.

At least 19 recordsLinked to original sources

Development of TIFUUN: Terahertz Integral Field Units with Universal Nanotechnology

TIFUUN (THz Integral Field Units with Universal Nanotechnology) is an ultra-wideband mm-submm wave imaging spectrometer that capitalizes on the highly scalable integrated superconducting spectrometer technology. TIFUUN has two slots for integral field units (IFUs), which can jointly be optimized as open-hardware for each astronomical observation in terms of spatial and spectral coverage. These IFUs can have observation frequencies in the range of 90--360 GHz, with spectral resolution up to $R\equiv F/\Delta F \le 1,000$, with up to $\sim$18,000 kinetic inductance detectors (shared by the two IFUs with a flexible ratio). The ultra-wide 4:1 (2 octave) bandwidth optics fits in a remarkably compact volume, by means of thin silicon lenses and a high chief ray angle design. The first pair of IFUs are being developed for the SUBLIME (Study of the Universe By Line Intensity Mapping Experiments) experiment that aims to map CII emission at redshift $\sim$6 to trace the cosmic large-scale structure and the buildup of galaxies during reionization, using TIFUUN on the ASTE 10-m telescope. The scalability, flexibility and compactness makes TIFUUN a highly compatible and portable system suited also for upcoming telescope facilities in the vicinity, such as FYST and AtLAST/LST.

astro-ph.IM

Characterization of Aluminum Microwave SQUID Multiplexers for CE$\nu$NS Detection

We present the design, fabrication, and characterization of an aluminum-based six-channel microwave SQUID multiplexer ($\mu$MUX) prototype for transition-edge sensor (TES) readout in the RICOCHET experiment. The device consists of aluminum coplanar-waveguide resonators and RF SQUIDs with Dolan-style Al/AlO$_x$/Al Josephson junctions. By measuring the resonator scattering parameters at a range of probe tone frequencies, powers, and flux bias points, we demonstrate agreement between the device response and existing multiplexer models. We also characterize the noise performance in both open-loop and flux-ramping modes. With a high electron mobility transistor (HEMT) amplifier, open-loop measurements yield a flux sensitivity of 1-1.5 $\mu\Phi_0/\sqrt{Hz}$. With flux-ramp modulation, low-frequency 1/f noise is suppressed, and the flux sensitivity is around 3-4 $\mu\Phi_0/\sqrt{Hz}$, corresponding to a current sensitivity of 24-33 $pA/\sqrt{Hz}$ at the input coil. We further demonstrate a reduction in readout noise by incorporating a Josephson traveling-wave parametric amplifier (JTWPA) between the $\mu$MUX and the HEMT. This achieves an open-loop flux sensitivity of 0.3-0.6 $\mu\Phi_0/\sqrt{Hz}$ and an effective system noise temperature below 1 K. These results establish aluminum $\mu$MUX devices as a viable and extensible readout technology for low-noise cryogenic detector arrays.

physics.ins-det

Enhanced Athermal Phonon Responsivity in a Kinetic Inductance Detector with Integrated Phonon Collectors

Cryogenic phonon detectors are adopted in light dark matter searches and coherent elastic neutrino-nucleus scattering experiments as they can achieve low energy thresholds. The phonon mediated sensing of silicon particle absorbers has already been proved with Kinetic Inductance Detectors (KIDs), acting both as sensors and athermal phonon absorbers. In this work we present the design and the performance of an improved detector design. In this architecture, the KID acts only as sensor and is coupled to dedicated phonon collectors. When a signal is coming from the substrate, the presence of a separated collector allows to detect an higher increase of quasi-particles density, thereby enhancing its responsivity. The meander of the KID is composed of a 77 nm trilayer wire of Aluminum-Titanium-Aluminum, while the phonon collectors are made of a 100 nm Aluminum layer and act as quasi-particles funnels. Inside the collectors, the absorbed athermal phonons generate quasi-particles which, after diffusion, are trapped in the lower-gap superconducting trilayer. The performance of this setup is compared to that of a standard phonon-mediated KID, showing an increased phonon collection efficiency by a factor of around 7.

physics.ins-det

Cross-Polarization Reduction in Kinetic Inductance Detectors Based on Quasi-Lumped Resonators

Kinetic Inductance Detectors (KIDs) have emerged as a leading technology for millimeter- and submillimeter-wave astronomy due to their high sensitivity, natural multiplexing capabilities and scalable fabrication. In polarization-sensitive applications-such as Cosmic Microwave Background (CMB) studies-cross-polarization, or unintended response to the orthogonal polarization, poses a significant limitation to measurement fidelity. This work investigates the origin of cross-polarization in meandered Lumped Element KIDs (LEKIDs), with particular emphasis on the role of parasitic currents in the interdigitated capacitor. A comparative study between conventional LEKIDs and a quasi-lumped resonator design is presented, demonstrating that removing the capacitive element may improve cross-polarization discrimination, confirming the capacitor's contribution to polarization leakage.

astro-ph.IM

Dark characterization of Ti/Al LEKIDs for the search of axions in the W-band

We report the electrical (dark) characterization of lumped-element kinetic inductance detectors (LEKIDs) fabricated from a Titanium/Aluminum bilayer and designed for broadband absorption in the W-band (75-110 GHz). These detectors are prototypes for future QCD axion search experiments within the Canfranc Axion Detection Experiment (CADEx), which demand sub 1e-19 W/Hz^0.5 sensitivities under low optical backgrounds. We combine a Mattis-Bardeen analysis to the temperature dependence of the detector parameters with noise spectroscopy to determine the electrical noise equivalent power (NEP). The minimum measured value for the electrical NEP is 3e-19 W/Hz0.5. Across the measured temperature range, we find that quasiparticle lifetime deviates from the expected BCS recombination law. Our analysis suggests that non-equilibrium relaxation is governed by spatial inhomogeneities in the superconducting gap and phonon diffusion effects. This work sets the road-map to achieve suitable and ultra-sensitive detectors in the W-band for dark matter axion search experiments.

physics.ins-det

Characterization of mini-CryoCube detectors from the Ricochet experiment commissioning at the Institut Laue-Langevin

The Ricochet experiment aims to measure the coherent elastic neutrino-nucleus scattering process from antineutrinos emitted by a research nuclear reactor operated by the Institut Laue-Langevin (Grenoble, France). This article presents a description of the Ricochet experimental installation and the detector performance achieved during its commissioning with a mini-CryoCube module consisting of three 42-gram germanium cryogenic calorimeters. The baseline resolutions and background levels are reported both during reactor-on and reactor-off periods, and as noise mitigation techniques were improved. A baseline resolution of 40 eV electron equivalent was achieved for the ionization channel after setup improvements, and the phonon channel resolutions ranged from 50 to 80 eV of total phonon energy. In the energy region from 2 to 7 keV, a nuclear recoil rate of 15(2) events/(kg day keV) is measured during the reactor-off period selecting events in coincidence with muon veto signals. This rate is in agreement with the cosmogenic neutron rate calculated from GEANT4 simulations. After the rejection of events in coincidence with signals in the muon veto detectors, a combined 90% C.L. limit on the nuclear recoil background of < 9 events/(kg day keV) is obtained in that energy region during the reactor-on period, which is compatible with our GEANT4 model calculation corresponding to a total rate of 5 events/(kg day keV). The sensitivity of this analysis was however found to be limited by a surface event contamination which is currently being addressed by the Ricochet Collaboration with upgraded detectors.

hep-ex

High-precision polarization measurements with Lumped Element Kinetic Inductance Detectors

This work aims to demonstrate that two arrays of Lumped Element Kinetic Inductance Detectors (LEKIDs), when employed in filled array configuration and separated by an external linear polarizer oriented at 45 degrees, can achieve the precision required by next-generation cosmological experiments. The focus here is on validating their ability to meet stringent uncertainty requirements, in particular for polarization angle reconstruction. To achieve this, the uncertainties in the reconstruction of the polarization angle have been characterized in the laboratory using a dedicated closed-circuit 100 mK dilution cryostat. This is optically coupled to a Martin-Puplett interferometer and a custom-designed sky simulator equipped with both photometric and polarized sources, allowing one to reproduce realistic ground-based observation conditions. This experimental setup allows us to generate intensity and polarization maps with diffraction-limited resolution, allowing us to determine the polarization angles and their associated uncertainties. The results show performance in line with expectations for the next generation CMB experiments. The polarization angle was reconstructed with an uncertainty of 6.5 arcmin.

astro-ph.IM

The PolarKID project: polarization measurements with KIDs for the next generation of CMB telescopes

The goal of the PolarKID project is testing a new method for the measurement of polarized sources, in order to identify all the possible instrumental systematic effects that could impact the detection of CMB B-modes of polarization. It employs the KISS (KIDs Interferometer Spectrum Survey) instrument coupled to a sky simulator and to sources such as point-like black bodies (simulating planets), a dipole (extended source) and a polarizer. We use filled-arrays Lumped Element Kinetic Inductance Detectors (LEKIDs) since they have multiple advantages when observing both in a photometry and in a polarimetry configuration

astro-ph.IM

CONCERTO: Instrument model of Fourier transform spectroscopy, white-noise components

Modern astrophysics relies on intricate instrument setups to meet the demands of sensitivity, sky coverage, and multi-channel observations. An example is the CONCERTO project, employing advanced technology like kinetic inductance detectors and a Martin-Puplett interferometer. This instrument, installed at the APEX telescope atop the Chajnantor plateau, began commissioning observations in April 2021. Following a successful commissioning phase that concluded in June 2021, CONCERTO was offered to the scientific community for observations, with a final observing run in December 2022. CONCERTO boasts an 18.5 arcmin field of view and a spectral resolution down to 1.45 GHz in the 130-310 GHz electromagnetic band. We developed a comprehensive instrument model of CONCERTO inspired by Fourier transform spectrometry principles to optimize performance and address systematic errors. This model integrates instrument noises, subsystem characteristics, and celestial signals, leveraging both physical data and simulations. Our methodology involves delineating simulation components, executing on-sky simulations, and comparing results with real observations. The resulting instrument model is pivotal, enabling a precise error correction and enhancing the reliability of astrophysical insights obtained from observational data. In this work, we focus on the description of three white-noise noise components included in the instrument model that characterize the white-noise level: the photon, the generation-recombination, and the amplifier noises.

astro-ph.IM

The case for an all-sky millimetre survey at sub-arcminute resolution

There are several new projects to survey the sky with millimetre eyes, the biggest being Simons Observatory and CMB-S4, in the Southern Hemisphere. The NIKA2 collaboration has acquired sufficient knowledge to build a large focal plane KID camera for a 15~m antenna. This would allow covering the whole Northern Hemisphere in five years at subarcminute resolution and with milliJansky point-source sensitivity. We describe the main scientific drivers for such a project: the SZ sky, the high-redshift millimetre Universe and the interstellar medium in our Galaxy and the nearby galaxies. We also show briefly the main difficulties (scientific, organisational, technical and financial).

astro-ph.IM

CONCERTO: instrument and status

CONCERTO (CarbON CII line in post-rEionization and ReionizaTiOn) is a low-resolution Fourier transform spectrometer dedicated to the study of star-forming galaxies and clusters of galaxies in the transparent millimeter windows from the ground. It is characterized by a wide instantaneous 18.6 arcmin field of view, operates at 130-310 GHz, and was installed on the 12-meter Atacama Pathfinder Experiment (APEX) telescope at 5100 m above sea level. CONCERTO's double focal planes host two arrays of 2152 kinetic inductance detectors and represent a pioneering instrument to meet a state-of-the-art scientific challenge. This paper introduces the CONCERTO instrument and explains its status, shows the first CONCERTO spectral maps of Orion, and describes the perspectives of the project.

astro-ph.IM

Superconductor-ferromagnet hybrids for non-reciprocal electronics and detectors

We review the use of hybrid thin films composed of superconductors and ferromagnets for creating non-reciprocal electronic components and self-biased detectors of electromagnetic radiation. We begin by introducing the theory behind these effects, as well as discussing various potential materials that can be used in the fabrication of these components. We then proceed with a detailed discussion on the fabrication and characterization of Al/EuS/Cu and EuS/Al/Co-based detectors, along with their noise analysis. Additionally, we suggest some approaches for multiplexing such self-biased detectors.

cond-mat.supr-con

A millimetre-wave superconducting hyper-spectral device

Millimetre-wave observations represent an important tool for Cosmology studies. The Line Intensity Mapping (LIM) technique has been proposed to map in three dimensions the specific intensity due to line (e.g. [CII], CO) emission, for example from the primordial galaxies, as a function of redshift. Hyper-spectral integrated devices have the potential to replace the current Fourier transform, or the planned Fabry-Perot-based instruments operating at millimetre and sub-millimetre wavelengths. The aim is to perform hyper-spectral mapping, with a spectral resolution R= 100-1000, over large, i.e. thousands of beams, instantaneous patches of the Sky. The innovative integrated device that we have developed allows avoiding moving parts, complicated and/or dispersive optics or tunable filters to be operated at cryogenic temperatures. The prototype hyper-spectral focal plane is sensitive in the 75-90GHz range and contains nineteen horns for sixteen spectral-imaging channels, each selecting a frequency band of about 0.1GHz. For each channel a conical horn antenna, coupled to a planar superconducting resonant absorber made of thin aluminium, collects the radiation. A capacitively coupled titanium-aluminium bilayer Lumped Element Kinetic Inductance Detector (LEKID) is then in charge of dissipating and sensing the super-current established in the resonant absorber. The prototype is fabricated with only two photo-lithography steps over a commercial mono-crystalline sapphire substrate. It exhibits a spectral resolution of about 800. The optical noise equivalent power of the best channels is in the observational relevant 4E-17W/sqrt(Hz) range. The average sensitivity of all the channels is around 1E-16W/sqrt(Hz). The device, as expected from 3-D simulations, is polarisation-sensitive, paving the way to spectro-polarimetry measurements over very large instantaneous field-of-views.

astro-ph.IM

CONCERTO : Digital processing for finding and tuning LEKIDs

We describe the on-line algorithms developed to probe Lumped Element Kinetic Inductance Detectors (LEKID) in this paper. LEKIDs are millimeter wavelength detectors for astronomy. LEKID arrays are currently operated in different instruments as: NIKA2 at the IRAM telescope in Spain, KISS at the Teide Observatory telescope in Tenerife, and CONCERTO at the APEX 12-meter telescope in Chile. LEKIDs are superconducting microwave resonators able to detect the incoming light at millimeter wavelengths and they are well adapted for frequency multiplexing (currently up to 360 pixels on a single microwave guide). Nevertheless, their use for astronomical observations requires specific readout and acquisition systems both to deal with the instrumental and multiplexing complexity, and to adapt to the observational requirements (e.g. fast sampling rate, background variations, on-line calibration, photometric accuracy, etc). This paper presents the different steps of treatment from identifying the resonance frequency of each LEKID to the continuous automatic control of drifting LEKID resonance frequencies induced by background variations.

astro-ph.IM

A horn-coupled millimeter-wave on-chip spectrometer based on Lumped Element Kinetic Inductance Detectors

Context. Millimetre-wave astronomy is an important tool for both general astrophysics studies and cosmology. A large number of unidentified sources are being detected by the large field-of-view continuum instruments operating on large telescopes. Aims. New smart focal planes are needed to bridge the gap between large bandwidth continuum instruments operating on single dish telescopes and the high spectral and angular resolution interferometers (e.g. ALMA in Chile, NOEMA in France). The aim is to perform low-medium spectral resolution observations and select a lower number of potentially interesting sources, i.e. high-redshift galaxies, for further follow-up. Methods. We have designed, fabricated and tested an innovative on-chip spectrometer sensitive in the 85-110~GHz range. It contains sixteen channels selecting a frequency band of about 0.2 GHz each. A conical horn antenna coupled to a slot in the ground plane collects the radiation and guides it to a mm-wave microstrip transmission line placed on the other side of the mono-crystalline substrate. The mm-wave line is coupled to a filter-bank. Each filter is capacitively coupled to a Lumped Element Kinetic Inductance Detector (LEKID). The microstrip configuration allows to benefit from the high quality, i.e. low losses, mono-crystalline substrate, and at the same time prevents direct, i.e. un-filtered, LEKID illumination. Results. The prototype spectrometer exhibit a spectral resolution R = lambda / Delta_lambda = 300. The optical noise equivalent power is in the low 1E-16W/sqrt(Hz) range for an incoming power of about 0.2pW per channel. The device is polarisation-sensitive, with a cross-polarisation lower than 1% for the best channels.

astro-ph.IM

CONCERTO: a breakthrough in wide field-of-view spectroscopy at millimeter wavelengths

CarbON CII line in post-rEionization and ReionizaTiOn (CONCERTO) is a low-resolution spectrometer with an instantaneous field-of-view of 18.6 arcmin, operating in the 130-310 GHz transparent atmospheric window. It is installed on the 12-meter Atacama Pathfinder Experiment (APEX) telescope at 5100 m above sea level. The Fourier transform spectrometer (FTS) contains two focal planes hosting a total of 4304 kinetic inductance detectors. The FTS interferometric pattern is recorded on the fly while continuously scanning the sky. One of the goals of CONCERTO is to characterize the large-scale structure of the Universe by observing the integrated emission from unresolved galaxies. This methodology is an innovative technique and is called line intensity mapping. In this paper, we describe the CONCERTO instrument, the effect of the vibration of the FTS beamsplitter, and the status of the CONCERTO main survey.

astro-ph.IM

Contact-less phonon detection with massive cryogenic absorbers

We have developed a contact-less technique for the real time measurement of a-thermal (Cooper-pair breaking) phonons in an absorber held at sub-Kelvin temperatures. In particular, a thin-film aluminum superconducting resonator was realized on a 30-grams high-resistivity silicon crystal. The lumped-element resonator is inductively excited/read-out by a radio-frequency microstrip feed-line deposited on another wafer; the sensor, a Kinetic Inductance Detector (KID), is read-out without any physical contact or wiring to the absorber. The resonator demonstrates excellent electrical properties, particularly in terms of its internal quality factor. The detection of alphas and gammas in the massive absorber is achieved, with an RMS energy resolution of about 1.4 keV, which is already interesting for particle physics applications. The resolution of this prototype detector is mainly limited by the low (about 0.3%) conversion efficiency of deposited energy to superconducting excitations (quasi-particles). The demonstrated technique can be further optimized, and used to produce large arrays of a-thermal phonon detectors, for use in rare events searches such as: dark matter direct detection,neutrino-less double beta decay, or coherent elastic neutrino-nucleus scattering.

physics.ins-det

Interplay between kinetic inductance, non-linearity and quasiparticle dynamics in granular aluminum MKIDs

Microwave kinetic inductance detectors (MKIDs) are thin film, cryogenic, superconducting resonators. Incident Cooper pair-breaking radiation increases their kinetic inductance, thereby measurably lowering their resonant frequency. For a given resonant frequency, the highest MKID responsivity is obtained by maximizing the kinetic inductance fraction $α$. However, in circuits with $α$ close to unity, the low supercurrent density reduces the maximum number of readout photons before bifurcation due to self-Kerr non-linearity, therefore setting a bound for the maximum $α$ before the noise equivalent power (NEP) starts to increase. By fabricating granular aluminum MKIDs with different resistivities, we effectively sweep their kinetic inductance from tens to several hundreds of pH per square. We find a NEP minimum in the range of $25\; \text{aW}/\sqrt{\text{Hz}}$ at $α\approx 0.9$, which results from a tradeoff between the onset of non-linearity and a non-monotonic dependence of the noise spectral density vs. resistivity.

cond-mat.supr-con