SearcharxivSearch

arXiv · 2605.24272

Characterization of Aluminum Microwave SQUID Multiplexers for CE$\nu$NS Detection

James Amidei·Antoine Armatol·Corinne Augier·Louis Bailly-Salins·Guillaume Baulieu·Laurent Bergé·Julien Billard·Juliette Blé·Gaby Brenot·Guillaume Bres·Jean-Louis Bret·Alexandre Broniatowski·Martino Calvo·Antonella Cavanna·Antoine Cazes·Emanuela Celi·David Chaize·Mohammed Chala·Maurice Chapellier·Luke Chaplinsky·Ran Chen·Ion Cojocari·Jules Colas·Laurent Couraud·Elspeth Cudmore·Maryvonne De Jesus·Pierre de Marcillac·Nicole Dombrowski·Louis Dumoulin·Alan Durnez·Romain Faure·Sylvain Ferriol·Enectali Figueroa-Feliciano·Joseph A. Formaggio·Stephane Fuard·Jules Gascon·Cloé Girard-Carillo·Andrea Giuliani·Corinne Goy·Cyrille Guerin·Leïla Haegel·Patrick M. Harrington·Scott A. Hertel·Cyrus F. Hirjibehedin·Christophe Hoarau·Ziqing Hong·Daemon Howard·Jean-Christophe Ianigro·Yong Jin·Alexandre Juillard·Dimitar Karaivanov·Temirlan Khussainov·Andrew Kubik·Jacob Lamblin·Tatiana Le Bellec·Laetitia Leroy·Mingyu Li·Alexey Lubashevskiy·Stefanos Marnieros·Romain Martin·Nicolas Martini·Julien Minet·Alessandro Monfardini·Franck Mounier·Bethany M. Niedzielski·Valentina Novati·Wiliam D. Oliver·Emiliano Olivieri·H. Douglas Pinckney·Denys V. Poda·Dmitrii Ponomarev·Jean-Sébastien Real·Faith C. Reyes·Alejandro Rodriguez·Sergey Rozov·Irina Rozova·Brianna Ryan·Deeksha Sabhari·Silvia Scorza·Kyle Serniak·Renaud Serra·Yegor Shevchik·Torsten Soldner·Hannah Stickler·Caitlyn Stone-Whitehead·Christian Ulysse·Wouter Van De Pontseele·Sergey Vasilyev·Paul Vittaz·Steven Weber·Evan Wolfe·Wayne Woods·Evgeny Yakushev·Jiatong Yang·Daniya Zinatulina

Abstract

We present the design, fabrication, and characterization of an aluminum-based six-channel microwave SQUID multiplexer ($\mu$MUX) prototype for transition-edge sensor (TES) readout in the RICOCHET experiment. The device consists of aluminum coplanar-waveguide resonators and RF SQUIDs with Dolan-style Al/AlO$_x$/Al Josephson junctions. By measuring the resonator scattering parameters at a range of probe tone frequencies, powers, and flux bias points, we demonstrate agreement between the device response and existing multiplexer models. We also characterize the noise performance in both open-loop and flux-ramping modes. With a high electron mobility transistor (HEMT) amplifier, open-loop measurements yield a flux sensitivity of 1-1.5 $\mu\Phi_0/\sqrt{Hz}$. With flux-ramp modulation, low-frequency 1/f noise is suppressed, and the flux sensitivity is around 3-4 $\mu\Phi_0/\sqrt{Hz}$, corresponding to a current sensitivity of 24-33 $pA/\sqrt{Hz}$ at the input coil. We further demonstrate a reduction in readout noise by incorporating a Josephson traveling-wave parametric amplifier (JTWPA) between the $\mu$MUX and the HEMT. This achieves an open-loop flux sensitivity of 0.3-0.6 $\mu\Phi_0/\sqrt{Hz}$ and an effective system noise temperature below 1 K. These results establish aluminum $\mu$MUX devices as a viable and extensible readout technology for low-noise cryogenic detector arrays.

Explore related subjects

Keep this discovery

BibTeXRIS

James Amidei, Antoine Armatol, Corinne Augier, Louis Bailly-Salins, Guillaume Baulieu, Laurent Bergé, Julien Billard, Juliette Blé, Gaby Brenot, Guillaume Bres, Jean-Louis Bret, Alexandre Broniatowski, Martino Calvo, Antonella Cavanna, Antoine Cazes, Emanuela Celi, David Chaize, Mohammed Chala, Maurice Chapellier, Luke Chaplinsky, Ran Chen, Ion Cojocari, Jules Colas, Laurent Couraud, Elspeth Cudmore, Maryvonne De Jesus, Pierre de Marcillac, Nicole Dombrowski, Louis Dumoulin, Alan Durnez, Romain Faure, Sylvain Ferriol, Enectali Figueroa-Feliciano, Joseph A. Formaggio, Stephane Fuard, Jules Gascon, Cloé Girard-Carillo, Andrea Giuliani, Corinne Goy, Cyrille Guerin, Leïla Haegel, Patrick M. Harrington, Scott A. Hertel, Cyrus F. Hirjibehedin, Christophe Hoarau, Ziqing Hong, Daemon Howard, Jean-Christophe Ianigro, Yong Jin, Alexandre Juillard, Dimitar Karaivanov, Temirlan Khussainov, Andrew Kubik, Jacob Lamblin, Tatiana Le Bellec, Laetitia Leroy, Mingyu Li, Alexey Lubashevskiy, Stefanos Marnieros, Romain Martin, Nicolas Martini, Julien Minet, Alessandro Monfardini, Franck Mounier, Bethany M. Niedzielski, Valentina Novati, Wiliam D. Oliver, Emiliano Olivieri, H. Douglas Pinckney, Denys V. Poda, Dmitrii Ponomarev, Jean-Sébastien Real, Faith C. Reyes, Alejandro Rodriguez, Sergey Rozov, Irina Rozova, Brianna Ryan, Deeksha Sabhari, Silvia Scorza, Kyle Serniak, Renaud Serra, Yegor Shevchik, Torsten Soldner, Hannah Stickler, Caitlyn Stone-Whitehead, Christian Ulysse, Wouter Van De Pontseele, Sergey Vasilyev, Paul Vittaz, Steven Weber, Evan Wolfe, Wayne Woods, Evgeny Yakushev, Jiatong Yang, Daniya Zinatulina. 2026-05-22. Characterization of Aluminum Microwave SQUID Multiplexers for CE$\nu$NS Detection. https://arxiv.org/abs/2605.24272

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det