SearcharxivSearch

arXiv subjects

Andrea Goldwurm

Publications and source records attributed to Andrea Goldwurm.

At least 19 recordsLinked to original sources

Fast Optical Variability of the TeV Blazar PKS 1725+123 Observed by SVOM-VT and Insights from Multi-wavelength Follow-up Observations

PKS 1725+123 is a flat-spectrum radio quasar (FSRQ) with a redshift of $z=0.586$. The detection of this object in the TeV band was reported by the MAGIC telescopes and H.E.S.S. in August 2025. Subsequently, we promptly initiated Target-of-Opportunity observations using the Space-based multi-band astronomical Variable Objects Monitor (SVOM) satellite. By analyzing the observational optical data from SVOM-VT and comprehensively examining the Fermi-LAT and Swift-XRT observational data, it was found that the source is in a high-flux state across the optical, X-ray, and GeV $γ$-ray bands around the time of the TeV detections. Its optical flux reaches a historically unprecedented high level and shows significant variability on timescale as short as minutes. The variability is accompanied by changes in the color index, exhibiting a bluer when brighter behavior during the high-flux state. Based on the simultaneous multi-wavelength data, we construct the broadband spectral energy distribution (SED) of the source in the high-flux state. PKS 1725+123 demonstrates a remarkably high synchrotron peak frequency, which is distinctly different from that of other FSRQs. We propose a two-zone spine-sheath jet model to reproduce this SED. The optical--X-ray emission is generated by the synchrotron process of the relativistic electrons within a compact zone. The inverse Compton (IC) scattering processes of the same electron population contribute to the low-energy end of the Fermi-LAT spectrum, while the high-energy end of the Fermi-LAT spectrum is ascribed to the IC scattering of the synchrotron photons within the compact zone by the higher-energy electrons in an extended region.

astro-ph.HE

High Energy Emission from the Galactic Center

The center of the Galaxy is a prominent source in X-rays and gamma-rays. The study of its high-energy (HE) emission is crucial in understanding the physical phenomena taking place in this dense and extreme environment, where the closest supermassive black hole (SMBH) to us, Sgr A*, is lurking nearly invisible, today, in most of the energy spectrum. These phenomena are probably common to other galactic nuclei and may explain the feedback processes between nuclear regions and galaxies, so important for the overall evolution of the Universe. The Galactic center HE emission is very complex and consists of both thermal and non thermal radiation produced by compact and extended sources, surrounded by more diffuse components. All these objects and media are interacting with each other in the narrow and dense Central Molecular Zone (CMZ). Some of them also show relevant extensions towards the Galactic poles, indicating energetic outflows that seem to link the center to the recently observed large Galactic polar structures. In spite of the fundamental advances obtained in the last twenty five years with the most sensitive X-ray and gamma-ray observatories, several questions remain open to investigations. We review here the main observational results and the open issues on the high-energy diagnostics of the Galactic nuclear activity, focusing on processes that take place in the CMZ, and in particular discussing the role of the present and past SMBH activities in powering this region and possibly the whole Galaxy.

astro-ph.HE

Detection of Oscillations in a Type I X-Ray Burst of 4U 0614+091 with SVOM/ECLAIRs

On 2025 January 10, a thermonuclear (Type I) X-ray burst from the neutron star low-mass X-ray binary \textit{4U~0614+091} was detected with the ECLAIRs instrument on board the \textit{SVOM} mission. We present here a time-resolved spectroscopic analysis of the burst, along with the detection of burst oscillations within a 51-second interval during the decay phase. The oscillation frequency is measured to be $ν= 413.674 \pm 0.002\,\mathrm{Hz}$, consistent with previous reports. However, we detect a significant downward frequency drift over the burst duration, characterized by $\dotν = (-4.7 \pm 0.3) \times 10^{-3}\,\mathrm{Hz\,s^{-1}}$. This frequency evolution is atypical compared to those observed in similar burst oscillation sources. We tentatively attribute the observed drift to a Doppler shift induced by orbital motion. Under this interpretation, the inferred orbital period must be shorter than 20 minutes, placing \textit{4U~0614+091} among the most compact known low-mass X-ray binaries.

astro-ph.HE

The X-ray Integral Field Unit at the end of the Athena reformulation phase

The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passive cooling via successive radiative panels at spacecraft level is now used to provide a 50 K thermal environment to an X-IFU owned cryostat. 4.5 K cooling is achieved via a single remote active cryocooler unit, while a multi-stage Adiabatic Demagnetization Refrigerator ensures heat lift down to the 50 mK required by the detectors. Amidst these changes, the core concept of the readout chain remains robust, employing Transition Edge Sensor microcalorimeters and a SQUID-based Time-Division Multiplexing scheme. Noteworthy is the introduction of a slower pixel. This enables an increase in the multiplexing factor (from 34 to 48) without compromising the instrument energy resolution, hence keeping significant system margins to the new 4 eV resolution requirement. This allows reducing the number of channels by more than a factor two, and thus the resource demands on the system, while keeping a 4' field of view (compared to 5' before). In this article, we will give an overview of this new architecture, before detailing its anticipated performances. Finally, we will present the new X-IFU schedule, with its short term focus on demonstration activities towards a mission adoption in early 2027.

astro-ph.IM

Coded Mask Instruments for Gamma-Ray Astronomy

Coded mask instruments have been used in high-energy astronomy for the last forty years now and designs for future hard X-ray/low gamma-ray telescopes are still based on this technique when they need to reach moderate angular resolutions over large field of views, particularly for observations dedicated to the, now flourishing, field of time domain astrophysics. However these systems are somehow unfamiliar to the general astronomers as they actually are two-step imaging devices where the recorded picture is very different from the imaged object and the data processing takes a crucial part in the reconstruction of the sky image. Here we present the concepts of these optical systems applied to high-energy astronomy, the basic reconstruction methods including some useful formulae and the trend of the expected and observed performances as function of the system designs. We review the historical developments and recall the flown space-borne coded mask instruments along with the description of a few relevant examples of major successful implementations and future projects in space astronomy.

astro-ph.IM

The Athena X-ray Integral Field Unit: a consolidated design for the system requirement review of the preliminary definition phase

The Athena X-ray Integral Unit (X-IFU) is the high resolution X-ray spectrometer, studied since 2015 for flying in the mid-30s on the Athena space X-ray Observatory, a versatile observatory designed to address the Hot and Energetic Universe science theme, selected in November 2013 by the Survey Science Committee. Based on a large format array of Transition Edge Sensors (TES), it aims to provide spatially resolved X-ray spectroscopy, with a spectral resolution of 2.5 eV (up to 7 keV) over an hexagonal field of view of 5 arc minutes (equivalent diameter). The X-IFU entered its System Requirement Review (SRR) in June 2022, at about the same time when ESA called for an overall X-IFU redesign (including the X-IFU cryostat and the cooling chain), due to an unanticipated cost overrun of Athena. In this paper, after illustrating the breakthrough capabilities of the X-IFU, we describe the instrument as presented at its SRR, browsing through all the subsystems and associated requirements. We then show the instrument budgets, with a particular emphasis on the anticipated budgets of some of its key performance parameters. Finally we briefly discuss on the ongoing key technology demonstration activities, the calibration and the activities foreseen in the X-IFU Instrument Science Center, and touch on communication and outreach activities, the consortium organisation, and finally on the life cycle assessment of X-IFU aiming at minimising the environmental footprint, associated with the development of the instrument. Thanks to the studies conducted so far on X-IFU, it is expected that along the design-to-cost exercise requested by ESA, the X-IFU will maintain flagship capabilities in spatially resolved high resolution X-ray spectroscopy, enabling most of the original X-IFU related scientific objectives of the Athena mission to be retained. (abridged).

astro-ph.IM

INTEGRAL reloaded: spacecraft, instruments and ground system

ESA's INTErnational Gamma-Ray Astrophysics Laboratory (INTEGRAL) was launched on 17 Oct 2002 at 06:41 CEST. Since then, it has been providing long, uninterrupted observations (up to about 47 hr, or 170 ksec, per satellite orbit of 2.7 days) with a large field-of-view (fully coded: 100 deg^2), msec time resolution, keV energy resolution, polarization measurements, as well as additional coverage in the optical. This is realized by two main instruments in the 15 keV to 10 MeV range, the spectrometer SPI (spectral resolution 3 keV at 1.8 MeV) and the imager IBIS (angular resolution 12 arcmin FWHM), complemented by X-ray (JEM-X; 3-35 keV) and optical (OMC; Johnson V-band) monitors. All instruments are co-aligned to simultaneously observe the target region. A particle radiation monitor (IREM) measures charged particle fluxes near the spacecraft. The Anti-coincidence subsystems of the main instruments are also efficient all-sky gamma-ray detectors, which provide omni-directional monitoring above ~75 keV. INTEGRAL can also rapidly (within a couple of hours) re-point and conduct Target of Opportunity observations. INTEGRAL has build an impressive legacy: e.g. discovery of >600 new high-energy sources; first-ever direct detection of 56Ni and 56Co radio-active decay lines from a Type Ia supernova; new insights on positron annihilation in the Galactic bulge and disk; pioneering gamma-ray polarization studies. INTEGRAL is also a successful in multi-messenger astronomy: INTEGRAL found the first prompt electromagnetic radiation in coincidence with a binary neutron star merger. More than 1750 papers based on INTEGRAL data have been published in refereed journals. Here we give a comprehensive update of the satellite status after more than 18 years of operations in a harsh space environment, and an account of the successful Ground Segment.

astro-ph.IM

Detection of polarized gamma-ray emission from the Crab nebula with Hitomi Soft Gamma-ray Detector

We present the results from the Hitomi Soft Gamma-ray Detector (SGD) observation of the Crab nebula. The main part of SGD is a Compton camera, which in addition to being a spectrometer, is capable of measuring polarization of gamma-ray photons. The Crab nebula is one of the brightest X-ray / gamma-ray sources on the sky, and, the only source from which polarized X-ray photons have been detected. SGD observed the Crab nebula during the initial test observation phase of Hitomi. We performed the data analysis of the SGD observation, the SGD background estimation and the SGD Monte Carlo simulations, and, successfully detected polarized gamma-ray emission from the Crab nebula with only about 5 ks exposure time. The obtained polarization fraction of the phase-integrated Crab emission (sum of pulsar and nebula emissions) is (22.1 $\pm$ 10.6)% and, the polarization angle is 110.7$^o$ + 13.2 / $-$13.0$^o$ in the energy range of 60--160 keV (The errors correspond to the 1 sigma deviation). The confidence level of the polarization detection was 99.3%. The polarization angle measured by SGD is about one sigma deviation with the projected spin axis of the pulsar, 124.0$^o$ $\pm$0.1$^o$.

astro-ph.HE

The Athena X-ray Integral Field Unit

The X-ray Integral Field Unit (X-IFU) is the high resolution X-ray spectrometer of the ESA Athena X-ray observatory. Over a field of view of 5' equivalent diameter, it will deliver X-ray spectra from 0.2 to 12 keV with a spectral resolution of 2.5 eV up to 7 keV on ~5 arcsecond pixels. The X-IFU is based on a large format array of super-conducting molybdenum-gold Transition Edge Sensors cooled at about 90 mK, each coupled with an absorber made of gold and bismuth with a pitch of 249 microns. A cryogenic anti-coincidence detector located underneath the prime TES array enables the non X-ray background to be reduced. A bath temperature of about 50 mK is obtained by a series of mechanical coolers combining 15K Pulse Tubes, 4K and 2K Joule-Thomson coolers which pre-cool a sub Kelvin cooler made of a 3He sorption cooler coupled with an Adiabatic Demagnetization Refrigerator. Frequency domain multiplexing enables to read out 40 pixels in one single channel. A photon interacting with an absorber leads to a current pulse, amplified by the readout electronics and whose shape is reconstructed on board to recover its energy with high accuracy. The defocusing capability offered by the Athena movable mirror assembly enables the X-IFU to observe the brightest X-ray sources of the sky (up to Crab-like intensities) by spreading the telescope point spread function over hundreds of pixels. Thus the X-IFU delivers low pile-up, high throughput (>50%), and typically 10 eV spectral resolution at 1 Crab intensities, i.e. a factor of 10 or more better than Silicon based X-ray detectors. In this paper, the current X-IFU baseline is presented, together with an assessment of its anticipated performance in terms of spectral resolution, background, and count rate capability. The X-IFU baseline configuration will be subject to a preliminary requirement review that is scheduled at the end of 2018.

astro-ph.IM

Hitomi X-ray Observation of the Pulsar Wind Nebula G21.5$-$0.9

We present results from the Hitomi X-ray observation of a young composite-type supernova remnant (SNR) G21.5$-$0.9, whose emission is dominated by the pulsar wind nebula (PWN) contribution. The X-ray spectra in the 0.8-80 keV range obtained with the Soft X-ray Spectrometer (SXS), Soft X-ray Imager (SXI) and Hard X-ray Imager (HXI) show a significant break in the continuum as previously found with the NuSTAR observation. After taking into account all known emissions from the SNR other than the PWN itself, we find that the Hitomi spectra can be fitted with a broken power law with photon indices of $Γ_1=1.74\pm0.02$ and $Γ_2=2.14\pm0.01$ below and above the break at $7.1\pm0.3$ keV, which is significantly lower than the NuSTAR result ($\sim9.0$ keV). The spectral break cannot be reproduced by time-dependent particle injection one-zone spectral energy distribution models, which strongly indicates that a more complex emission model is needed, as suggested by recent theoretical models. We also search for narrow emission or absorption lines with the SXS, and perform a timing analysis of PSR J1833$-$1034 with the HXI and SGD. No significant pulsation is found from the pulsar. However, unexpectedly, narrow absorption line features are detected in the SXS data at 4.2345 keV and 9.296 keV with a significance of 3.65 $σ$. While the origin of these features is not understood, their mere detection opens up a new field of research and was only possible with the high resolution, sensitivity and ability to measure extended sources provided by an X-ray microcalorimeter.

astro-ph.HE

Temperature Structure in the Perseus Cluster Core Observed with Hitomi

The present paper investigates the temperature structure of the X-ray emitting plasma in the core of the Perseus cluster using the 1.8--20.0 keV data obtained with the Soft X-ray Spectrometer (SXS) onboard the Hitomi Observatory. A series of four observations were carried out, with a total effective exposure time of 338 ks and covering a central region $\sim7'$ in diameter. The SXS was operated with an energy resolution of $\sim$5 eV (full width at half maximum) at 5.9 keV. Not only fine structures of K-shell lines in He-like ions but also transitions from higher principal quantum numbers are clearly resolved from Si through Fe. This enables us to perform temperature diagnostics using the line ratios of Si, S, Ar, Ca, and Fe, and to provide the first direct measurement of the excitation temperature and ionization temperature in the Perseus cluster. The observed spectrum is roughly reproduced by a single temperature thermal plasma model in collisional ionization equilibrium, but detailed line ratio diagnostics reveal slight deviations from this approximation. In particular, the data exhibit an apparent trend of increasing ionization temperature with increasing atomic mass, as well as small differences between the ionization and excitation temperatures for Fe, the only element for which both temperatures can be measured. The best-fit two-temperature models suggest a combination of 3 and 5 keV gas, which is consistent with the idea that the observed small deviations from a single temperature approximation are due to the effects of projection of the known radial temperature gradient in the cluster core along the line of sight. Comparison with the Chandra/ACIS and the XMM-Newton/RGS results on the other hand suggests that additional lower-temperature components are present in the ICM but not detectable by Hitomi SXS given its 1.8--20 keV energy band.

astro-ph.HE

Atomic data and spectral modeling constraints from high-resolution X-ray observations of the Perseus cluster with Hitomi

The Hitomi SXS spectrum of the Perseus cluster, with $\sim$5 eV resolution in the 2-9 keV band, offers an unprecedented benchmark of the atomic modeling and database for hot collisional plasmas. It reveals both successes and challenges of the current atomic codes. The latest versions of AtomDB/APEC (3.0.8), SPEX (3.03.00), and CHIANTI (8.0) all provide reasonable fits to the broad-band spectrum, and are in close agreement on best-fit temperature, emission measure, and abundances of a few elements such as Ni. For the Fe abundance, the APEC and SPEX measurements differ by 16%, which is 17 times higher than the statistical uncertainty. This is mostly attributed to the differences in adopted collisional excitation and dielectronic recombination rates of the strongest emission lines. We further investigate and compare the sensitivity of the derived physical parameters to the astrophysical source modeling and instrumental effects. The Hitomi results show that an accurate atomic code is as important as the astrophysical modeling and instrumental calibration aspects. Substantial updates of atomic databases and targeted laboratory measurements are needed to get the current codes ready for the data from the next Hitomi-level mission.

astro-ph.HE

Glimpses of the past activity of Sgr A* inferred from X-ray echoes in Sgr C

For a decade now, evidence has accumulated that giant molecular clouds located within the central molecular zone of our Galaxy reflect X-rays coming from past outbursts of the supermassive black hole Sgr A*. However, the number of illuminating events as well as their ages and durations are still unresolved questions. We aim to reconstruct parts of the history of Sgr A* by studying this reflection phenomenon in the molecular complex Sgr C and by determining the line-of-sight positions of its main bright substructures. Using observations made with XMM-Newton and Chandra between 2000 and 2014, we investigated the variability of the reflected emission. We carried out an imaging and a spectral analysis. We also used a Monte Carlo model of the reflected spectra to constrain the line-of-sight positions of the brightest clumps, and hence to assign an approximate date to the associated illuminating events. We show that the emission from Sgr C exhibits significant variability in both space and time, which confirms its reflection origin. The most likely illuminating source is Sgr A*. We report two distinct variability timescales, as one clump undergoes a sudden rise and fall in about 2005, while two others vary smoothly throughout the whole 2000-2014 period. By fitting the Monte Carlo model to the data, we are able to place tight constraints on the 3D positions of the clumps. These two independent approaches provide a consistent picture of the past activity of Sgr A*, since the two slowly varying clumps are located on the same wavefront, while the rapidly varying clump corresponds to a different wavefront, that is, to a different illuminating event. We show that Sgr A* experienced at least two powerful outbursts in the past 300 years, and for the first time, we provide an estimation of their age. Extending this approach to other molecular complexes will allow this scenario to be tested further.

astro-ph.HE

Hitomi Observations of the LMC SNR N132D: Highly Redshifted X-ray Emission from Iron Ejecta

We present Hitomi observations of N132D, a young, X-ray bright, O-rich core-collapse supernova remnant in the Large Magellanic Cloud (LMC). Despite a very short observation of only 3.7 ks, the Soft X-ray Spectrometer (SXS) easily detects the line complexes of highly ionized S K and Fe K with 16-17 counts in each. The Fe feature is measured for the first time at high spectral resolution. Based on the plausible assumption that the Fe K emission is dominated by He-like ions, we find that the material responsible for this Fe emission is highly redshifted at ~800 km/s compared to the local LMC interstellar medium (ISM), with a 90% credible interval of 50-1500 km/s if a weakly informative prior is placed on possible line broadening. This indicates (1) that the Fe emission arises from the supernova ejecta, and (2) that these ejecta are highly asymmetric, since no blue-shifted component is found. The S K velocity is consistent with the local LMC ISM, and is likely from swept-up ISM material. These results are consistent with spatial mapping that shows the He-like Fe concentrated in the interior of the remnant and the S tracing the outer shell. The results also show that even with a very small number of counts, direct velocity measurements from Doppler-shifted lines detected in extended objects like supernova remnants are now possible. Thanks to the very low SXS background of ~1 event per spectral resolution element per 100 ks, such results are obtainable during short pointed or slew observations with similar instruments. This highlights the power of high-spectral-resolution imaging observations, and demonstrates the new window that has been opened with Hitomi and will be greatly widened with future missions such as the X-ray Astronomy Recovery Mission (XARM) and Athena.

astro-ph.HE

Glimpse of the highly obscured HMXB IGR J16318-4848 with Hitomi

We report a Hitomi observation of IGR J16318-4848, a high-mass X-ray binary system with an extremely strong absorption of N_H~10^{24} cm^{-2}. Previous X-ray studies revealed that its spectrum is dominated by strong fluorescence lines of Fe as well as continuum emission. For physical and geometrical insight into the nature of the reprocessing material, we utilize the high spectroscopic resolving power of the X-ray microcalorimeter (the soft X-ray spectrometer; SXS) and the wide-band sensitivity by the soft and hard X-ray imager (SXI and HXI) aboard Hitomi. Even though photon counts are limited due to unintended off-axis pointing, the SXS spectrum resolves Fe K{α_1} and K{α_2} lines and puts strong constraints on the line centroid and width. The line width corresponds to the velocity of 160^{+300}_{-70} km s^{-1}. This represents the most accurate, and smallest, width measurement of this line made so far from any X-ray binary, much less than the Doppler broadening and shift expected from speeds which are characteristic of similar systems. Combined with the K-shell edge energy measured by the SXI and HXI spectra, the ionization state of Fe is estimated to be in the range of Fe I--IV. Considering the estimated ionization parameter and the distance between the X-ray source and the absorber, the density and thickness of the materials are estimated. The extraordinarily strong absorption and the absence of a Compton shoulder component is confirmed. These characteristics suggest reprocessing materials which are distributed in a narrow solid angle or scattering primarily with warm free electrons or neutral hydrogen.

astro-ph.HE

Hitomi Observation of Radio Galaxy NGC 1275: The First X-ray Microcalorimeter Spectroscopy of Fe-Kα Line Emission from an Active Galactic Nucleus

The origin of the narrow Fe-Kα fluorescence line at 6.4 keV from active galactic nuclei has long been under debate; some of the possible sites are the outer accretion disk, the broad line region, a molecular torus, or interstellar/intracluster media. In February-March 2016, we performed the first X-ray microcalorimeter spectroscopy with the Soft X-ray Spectrometer (SXS) onboard the Hitomi satellite of the Fanaroff-Riley type I radio galaxy NGC 1275 at the center of the Perseus cluster of galaxies. With the high energy resolution of ~5 eV at 6 keV achieved by Hitomi/SXS, we detected the Fe-Kα line with ~5.4 σ significance. The velocity width is constrained to be 500-1600 km s$^{-1}$ (FWHM for Gaussian models) at 90% confidence. The SXS also constrains the continuum level from the NGC 1275 nucleus up to ~20 keV, giving an equivalent width ~20 eV of the 6.4 keV line. Because the velocity width is narrower than that of broad Hα line of ~2750 km s$^{-1}$, we can exclude a large contribution to the line flux from the accretion disk and the broad line region. Furthermore, we performed pixel map analyses on the Hitomi/SXS data and image analyses on the Chandra archival data, and revealed that the Fe-Kα line comes from a region within ~1.6 kpc from the NGC 1275 core, where an active galactic nucleus emission dominates, rather than that from intracluster media. Therefore, we suggest that the source of the Fe-Kα line from NGC 1275 is likely a low-covering fraction molecular torus or a rotating molecular disk which probably extends from a pc to hundreds pc scale in the active galactic nucleus system.

astro-ph.HE

Atmospheric gas dynamics in the Perseus cluster observed with Hitomi

Extending the earlier measurements reported in Hitomi collaboration (2016, Nature, 535, 117), we examine the atmospheric gas motions within the central 100~kpc of the Perseus cluster using observations obtained with the Hitomi satellite. After correcting for the point spread function of the telescope and using optically thin emission lines, we find that the line-of-sight velocity dispersion of the hot gas is remarkably low and mostly uniform. The velocity dispersion reaches maxima of approximately 200~km~s$^{-1}$ toward the central active galactic nucleus (AGN) and toward the AGN inflated north-western `ghost' bubble. Elsewhere within the observed region, the velocity dispersion appears constant around 100~km~s$^{-1}$. We also detect a velocity gradient with a 100~km~s$^{-1}$ amplitude across the cluster core, consistent with large-scale sloshing of the core gas. If the observed gas motions are isotropic, the kinetic pressure support is less than 10\% of the thermal pressure support in the cluster core. The well-resolved optically thin emission lines have Gaussian shapes, indicating that the turbulent driving scale is likely below 100~kpc, which is consistent with the size of the AGN jet inflated bubbles. We also report the first measurement of the ion temperature in the intracluster medium, which we find to be consistent with the electron temperature. In addition, we present a new measurement of the redshift to the brightest cluster galaxy NGC~1275.

astro-ph.HE

Measurements of resonant scattering in the Perseus cluster core with Hitomi SXS

Thanks to its high spectral resolution (~5 eV at 6 keV), the Soft X-ray Spectrometer (SXS) on board Hitomi enables us to measure the detailed structure of spatially resolved emission lines from highly ionized ions in galaxy clusters for the first time. In this series of papers, using the SXS we have measured the velocities of gas motions, metallicities and the multi-temperature structure of the gas in the core of the Perseus cluster. Here, we show that when inferring physical properties from line emissivities in systems like Perseus, the resonant scattering (RS) effect should be taken into account. In the Hitomi waveband, RS mostly affects the FeXXV He$α$ line ($w$) - the strongest line in the spectrum. The flux measured by Hitomi in this line is suppressed by a factor ~1.3 in the inner ~30 kpc, compared to predictions for an optically thin plasma; the suppression decreases with the distance from the center. The $w$ line also appears slightly broader than other lines from the same ion. The observed distortions of the $w$ line flux, shape and distance dependence are all consistent with the expected effect of the resonant scattering in the Perseus core. By measuring the ratio of fluxes in optically thick ($w$) and thin (FeXXV forbidden, He$β$, Ly$α$) lines, and comparing these ratios with predictions from Monte Carlo radiative transfer simulations, the velocities of gas motions have been obtained. The results are consistent with the direct measurements of gas velocities from line broadening described elsewhere in this series, although the systematic and statistical uncertainties remain significant. Further improvements in the predictions of line emissivities in plasma models, and deeper observations with future X-ray missions will enable RS measurements to provide powerful constraints on the amplitude and anisotropy of clusters gas motions.

astro-ph.HE