Searcharxiv⌕ Search

arXiv subjects

Andreas Tünnermann

Publications and source records attributed to Andreas Tünnermann.

41 records · Page 3Linked to original sources

Realization of a monolithic high-reflectivity cavity mirror from a single silicon crystal

We report on the first experimental realization of a high-reflectivity cavity mirror that solely consists of a single silicon crystal. Since no material was added to the crystal, the urgent problem of 'coating thermal noise' that currently limits classical as well as quantum measurements is avoided. Our mirror is based on a surface nanostructure that creates a resonant surface waveguide. In full agreement with a rigorous model we realized a reflectivity of (99.79+/-0.01)% at a wavelength of 1.55 μm, and achieved a cavity finesse of 2784. We anticipate that our achievement will open the avenue to next generation high-precision experiments targeting fundamental questions of physics.

physics.optics↗

Geometric potential and transport in photonic topological crystals

We report on the experimental realization of an optical analogue of a quantum geometric potential for light wave packets constrained on thin dielectric guiding layers fabricated in silica by the femtosecond laser writing technology. We further demonstrate the optical version of a topological crystal, with the observation of Bloch oscillations and Zener tunneling of purely geometric nature.

physics.optics↗

On the mechanical quality factors of cryogenic test masses from fused silica and crystalline quartz

Current interferometric gravitational wave detectors (IGWDs) are operated at room temperature with test masses made from fused silica. Fused silica shows very low absorption at the laser wavelength of 1064 nm. It is also well suited to realize low thermal noise floors in the detector signal band since it offers low mechanical loss, i. e. high quality factors (Q factors) at room temperature. However, for a further reduction of thermal noise, cooling the test masses to cryogenic temperatures may prove an interesting technique. Here we compare the results of Q factor measurements at cryogenic temperatures of acoustic eigenmodes of test masses from fused silica and its crystalline counterpart. Our results show that the mechanical loss of fused silica increases with lower temperature and reaches a maximum at 30 K for frequencies of slightly above 10 kHz. The losses of crystalline quartz generally show lower values and even fall below the room temperature values of fused silica below 10 K. Our results show that in comparison to fused silica, crystalline quartz has a considerably narrower and lower dissipation peak on cooling and thus has more promise as a test mass material for IGDWs operated at cryogenic temperatures. The origin of the different Q factor versus temperature behavior of the two materials is discussed.

gr-qc↗

Mechanical losses in low loss materials studied by Cryogenic Resonant Acoustic spectroscopy of bulk materials (CRA spectroscopy)

Mechanical losses of crystalline silicon and calcium fluoride have been analyzed in the temperature range from 5 to 300 K by our novel mechanical spectroscopy method, cryogenic resonant acoustic spectroscopy of bulk materials (CRA spectrocopy). The focus lies on the interpretation of the measured data according to phonon-phonon interactions and defect induced losses in consideration of the excited mode shape.

cond-mat.other↗

High-sensitivity tool for studying phonon related mechanical losses in low loss materials

Fundamental mechanical loss mechanisms exist even in very pure materials, for instance, due to the interactions of excited acoustic waves with thermal phonons. A reduction of these losses in a certain frequency range is desired in high precision instruments like gravitational wave detectors. Systematic analyses of the mechanical losses in those low loss materials are essential for this aim, performed in a highly sensitive experimental set-up. Our novel method of mechanical spectroscopy, cryogenic resonant acoustic spectroscopy of bulk materials (CRA spectroscopy), is well suited to systematically determine losses at the resonant frequencies of the samples of less than 10^(-9) in the wide temperature range from 5 to 300 K. A high precision set-up in a specially built cryostat allows contactless excitation and readout of the oscillations of the sample. The experimental set-up and measuring procedure are described. Limitations to our experiment due to external loss mechanisms are analysed. The influence of the suspension system as well as the sample preparation is explained.

cond-mat.other↗