SearcharxivSearch

arXiv subjects

Aneesh Rangnekar

Publications and source records attributed to Aneesh Rangnekar.

At least 19 recordsLinked to original sources

Parameter-Efficient pretrained-CT-to-MRI Transfer for Rectal Cancer Segmentation: Performance-Calibration Trade-offs

Accurate rectal cancer segmentation from magnetic resonance imaging (MRI) is essential for adaptive radiotherapy and tumor response assessment, but deployment also requires computational efficiency and informative, calibrated uncertainty estimates. We therefore introduce SWIFT, a SWin pretrained model wIth parameter-eFficient and Tumor-aware fine-tuning for rectal cancer segmentation. A Swin V2 encoder pretrained on 10,444 public 3D CT volumes using a DINOv2-style objective was adapted to T2-weighted MRI through four cumulative configurations: full fine-tuning (SWIFT), decoder compression (SWIFTe), low-rank adaptation (SWIFTe-LoRA), and a four-member LoRA-decoder ensemble (SWIFTe-LDE4). Geometric accuracy, tumor detection, radiomic agreement, and probability calibration were evaluated on a held-out 247-case test set from a single-institution cohort acquired using 1.5 or 3 Tesla GE scanners. Compared with SWIFT, SWIFTe reduced total parameters by 70.1% (from 72.8M to 21.8M) and increased tumor detection rate from 89.9% to 93.9%, while achieving a slightly lower median surface DSC (0.61 versus 0.62) and improved radiomic agreement. In a separate SWIFTe ablation, removing tumor-aware augmentation reduced detection from 93.9% to 89.9% but increased surface DSC from 0.61 to 0.64, demonstrating a detection-boundary-agreement trade-off. SWIFTe-LoRA used 14.6% of SWIFTe's trainable parameters while retaining similar segmentation performance. SWIFTe-LDE4 achieved the lowest calibration errors among the four configurations after temperature scaling (expected calibration error, 0.217; Brier score, 0.222), although the absolute expected calibration error indicates residual miscalibration. Similar efficiency-calibration patterns were observed using the public VoCo checkpoint, supporting robustness across pretrained initializations rather than external clinical generalizability.

cs.CV

Tumor-aware augmentation with task-guided attention analysis improves rectal cancer segmentation from magnetic resonance images

Although self-supervised pretraining is expected to learn broadly transferable representations, its effectiveness across imaging modalities substantially different from the pretraining domain, and on complex tumor-segmentation tasks, remains understudied. Evaluating CT-pretrained transformers on MRI rectal cancer segmentation, we identified two interacting failure modes in CT-to-MRI transfer: (a) inefficient token usage caused by zero-padding to match pretrained input dimensions, and (b) ineffective feature adaptation. We investigated these vulnerabilities using two primary CT-pretrained hierarchical shifted-window transformer backbones, SMIT and Swin UNETR, together with VoCo as a large-scale-pretrained supporting benchmark; these models differ in pretraining objectives and datasets. Mechanistic analysis leveraged an attention dilution index (ADI), an entropy-based metric quantifying attention diverted toward uninformative padding tokens, and centered kernel alignment (CKA) to measure feature reuse during MRI adaptation. ADI increased with zero-padding, while high feature reuse did not necessarily translate to improved downstream accuracy. To mitigate these issues, we introduced two interventions: a tumor-aware augmentation strategy to expand tumor appearance heterogeneity coverage, and an anisotropic cropping strategy to restore token efficiency. Fine-tuning with these strategies on identical rectal MRI datasets yielded detection rates of 91.1% (225/247) and 88.7% (219/247) for the primary SMIT and Swin UNETR backbones, with the supporting VoCo benchmark reaching 90.3% (223/247), demonstrating significantly improved robustness under CT-to-MRI transfer. This study is among the first to examine when pretrained transformers fail to transfer across imaging modalities and demonstrates how targeted mitigation strategies can systematically overcome cross-modality transfer limitations.

eess.IV

Tumor-anchored deep feature random forests for out-of-distribution detection in lung cancer segmentation

Accurate segmentation of lung tumors from 3D computed tomography (CT) scans is essential for automated treatment planning and response assessment. Despite self-supervised pretraining on numerous datasets, state-of-the-art transformer backbones remain susceptible to out-of-distribution (OOD) inputs, often producing confidently incorrect segmentations with potential for risk in clinical deployment. Hence, we introduce RF-Deep, a lightweight post-hoc random forests-based framework that leverages deep features trained with limited outlier exposure, requiring as few as 40 labeled scans (20 in-distribution and 20 OOD), to improve scan-level OOD detection. RF-Deep repurposes the hierarchical features from the pretrained-then-finetuned segmentation backbones, aggregating features from multiple regions-of-interest anchored to predicted tumor regions to capture OOD likelihood. We evaluated RF-Deep on 2,232 CT volumes spanning near-OOD (pulmonary embolism, COVID-19 negative) and far-OOD (kidney cancer, healthy pancreas) datasets. RF-Deep achieved AUROC >~93 on the challenging near-OOD datasets, where it outperformed the next best method by 4--7 percentage points, and produced near-perfect detection (AUROC >~99) on far-OOD datasets. The approach also showed transferability to two blinded validation datasets under the ensemble configuration (COVID-19 positive and breast cancer; AUROC >~94). RF-Deep maintained consistent performance across backbones of different depths and pretraining strategies, demonstrating applicability of post-hoc detectors as a safety filter for clinical deployment of tumor segmentation pipelines.

eess.IV

Dual Cross-Attention Siamese Transformer for Rectal Tumor Regrowth Assessment in Watch-and-Wait Endoscopy

Increasing evidence supports watch-and-wait (WW) surveillance for patients with rectal cancer who show clinical complete response (cCR) at restaging following total neoadjuvant treatment (TNT). However, accurate methods to early detect local regrowth (LR) from follow-up endoscopy images during WW are essential to manage care and prevent distant metastases. Hence, we developed a Siamese Swin Transformer with Dual Cross-Attention (SSDCA) to combine longitudinal endoscopic images at restaging and follow-up and distinguish cCR from LR. SSDCA leverages pretrained Swin Transformers to extract domain agnostic features and enhance robustness to imaging variations. Dual cross attention is implemented to emphasize features from the paired scans without requiring any spatial alignment to predict response. SSDCA as well as Swin-based baselines were trained using image pairs from 135 patients and evaluated on a held-out set of image pairs from 62 patients. SSDCA produced the best balanced accuracy (81.76% $\pm$ 0.04), sensitivity (90.07% $\pm$ 0.08), and specificity (72.86% $\pm$ 0.05). Robustness analysis showed stable performance irrespective of artifacts including blood, stool, telangiectasia, and poor image quality. UMAP clustering of extracted features showed maximal inter-cluster separation (1.45 $\pm$ 0.18) and minimal intra-cluster dispersion (1.07 $\pm$ 0.19) with SSDCA, confirming discriminative representation learning. Code and weights available at: https://github.com/Jotanator/SSDCA

cs.CV

Prediction of Rectal Cancer Regrowth from Longitudinal Endoscopy

Clinical trial studies indicate benefit of watch-and-wait (WW) surveillance for patients with rectal cancer showing a complete or near clinical response (CR) directly after treatment (restaging). However, there are no objectively accurate methods to early detect local tumor regrowth (LR) in patients undergoing WW from follow-up exams. Hence, we developed Temporal Rectal Endoscopy Cross-attention (TREX), a longitudinal deep learning approach that combines pairs of images acquired at restaging and follow-up to distinguish CR from LR. TREX uses pretrained Swin Transformers in a siamese setting to extract features from longitudinal images and dual cross-attention to combine the features without spatial co-registration between image pairs. TREX and Swin-based baselines were trained under two settings: (a) detecting LR or CR at the last available follow-up and (b) early detection of LR at 3--6, 6--12, and 12--24 months before clinical confirmation. TREX achieved the highest accuracy in detecting LR with a high sensitivity of 97% $\pm$ 6% and a balanced accuracy of 90% $\pm$ 3%, and outperformed all baselines in early detection at both 3--6 (74% $\pm$ 1%) and 6--12 months (62% $\pm$ 4%) prior to clinical detection. Clinical validation via a surgeon survey showed that TREX matched attending-level overall accuracy (TREX: 86.21% vs.\ Clinicians: 87.84% $\pm$ 1.28%). Finally, we explored TREX's ability to predict treatment response by combining pre-treatment (pre-TNT) and restaging endoscopies, achieving a balanced accuracy of 73% $\pm$ 12%. These results show that longitudinal deep learning analysis of endoscopy may improve surveillance and enable earlier identification of rectal cancer regrowth.

cs.CV

Co-distilled attention guided masked image modeling with noisy teacher for self-supervised learning on medical images

Masked image modeling (MIM) is a highly effective self-supervised learning (SSL) approach to extract useful feature representations from unannotated data. Predominantly used random masking methods make SSL less effective for medical images due to the contextual similarity of neighboring patches, leading to information leakage and SSL simplification. Hierarchical shifted window (Swin) transformer, a highly effective approach for medical images cannot use advanced masking methods as it lacks a global [CLS] token. Hence, we introduced an attention guided masking mechanism for Swin within a co-distillation learning framework to selectively mask semantically co-occurring and discriminative patches, to reduce information leakage and increase the difficulty of SSL pretraining. However, attention guided masking inevitably reduces the diversity of attention heads, which negatively impacts downstream task performance. To address this, we for the first time, integrate a noisy teacher into the co-distillation framework (termed DAGMaN) that performs attentive masking while preserving high attention head diversity. We demonstrate the capability of DAGMaN on multiple tasks including full- and few-shot lung nodule classification, immunotherapy outcome prediction, tumor segmentation, and unsupervised organs clustering.

cs.CV

Transformer-based cardiac substructure segmentation from contrast and non-contrast computed tomography for radiotherapy planning

Accurate segmentation of cardiac substructures on computed tomography (CT) scans is essential for radiotherapy planning but typically requires large annotated datasets and often generalizes poorly across imaging protocols and patient variations. This study evaluated whether pretrained transformers enable data-efficient training using a fixed architecture with balanced curriculum learning. A hybrid pretrained transformer-convolutional network (SMIT) was fine-tuned on lung cancer patients (Cohort I, N $=$ 180) imaged in the supine position and validated on 60 held-out Cohort I patients and 65 breast cancer patients (Cohort II) imaged in both supine and prone positions. Two configurations were evaluated: SMIT-Balanced (32 contrast-enhanced CTs and 32 non-contrast CTs) and SMIT-Oracle (180 CTs). Performance was compared with nnU-Net and TotalSegmentator. Segmentation accuracy was assessed primarily using the 95th percentile Hausdorff distance (HD95), with radiation dose and overlap-based metrics evaluated as secondary endpoints. SMIT-Balanced achieved accuracy comparable to SMIT-Oracle despite using 64$\%$ fewer training scans. On Cohort I, HD95 was 6.6 $\pm$ 4.3 mm versus 5.4 $\pm$ 2.6 mm, and on Cohort II, 10.0 $\pm$ 9.4 mm versus 9.4 $\pm$ 9.8 mm, respectively, demonstrating robustness to patient, imaging, and data variations. Radiation dose metrics derived from SMIT segmentations were equivalent to those from manual delineations. Although nnU-Net improved over the publicly trained TotalSegmentator, it showed reduced cross-domain robustness compared to SMIT. Balanced curriculum training reduced labeled data requirements without compromising accuracy relative to the oracle model and maintained robustness across patient and imaging variations. Pretraining reduced dependence on data domain and obviated the need for data-specific architectural reconfiguration required by nnU-Net.

eess.IV

Random forest-based out-of-distribution detection for robust lung cancer segmentation

Accurate detection and segmentation of cancerous lesions from computed tomography (CT) scans is essential for automated treatment planning and cancer treatment response assessment. Transformer-based models with self-supervised pretraining can produce reliably accurate segmentation from in-distribution (ID) data but degrade when applied to out-of-distribution (OOD) datasets. We address this challenge with RF-Deep, a random forest classifier that utilizes deep features from a pretrained transformer encoder of the segmentation model to detect OOD scans and enhance segmentation reliability. The segmentation model comprises a Swin Transformer encoder, pretrained with masked image modeling (SimMIM) on 10,432 unlabeled 3D CT scans covering cancerous and non-cancerous conditions, with a convolution decoder, trained to segment lung cancers in 317 3D scans. Independent testing was performed on 603 3D CT public datasets that included one ID dataset and four OOD datasets comprising chest CTs with pulmonary embolism (PE) and COVID-19, and abdominal CTs with kidney cancers and healthy volunteers. RF-Deep detected OOD cases with a FPR95 of 18.26%, 27.66%, and less than 0.1% on PE, COVID-19, and abdominal CTs, consistently outperforming established OOD approaches. The RF-Deep classifier provides a simple and effective approach to enhance reliability of cancer segmentation in ID and OOD scenarios.

eess.IV

MHub.ai: A Simple, Standardized, and Reproducible Platform for AI Models in Medical Imaging

Artificial intelligence (AI) has the potential to transform medical imaging by automating image analysis and accelerating clinical research. However, research and clinical use are limited by the wide variety of AI implementations and architectures, inconsistent documentation, and reproducibility issues. Here, we introduce MHub$.$ai, an open-source, container-based platform that standardizes access to AI models with minimal configuration, promoting accessibility and reproducibility in medical imaging. MHub$.$ai packages models from peer-reviewed publications into standardized containers that support direct processing of DICOM and other formats, provide a unified application interface, and embed structured metadata. Each model is accompanied by publicly available reference data that can be used to confirm model operation. MHub$.$ai includes an initial set of state-of-the-art segmentation, prediction, and feature extraction models for different modalities. The modular framework enables adaptation of any model and supports community contributions. We demonstrate the utility of the platform in a clinical use case through comparative evaluation of lung segmentation models. To further strengthen transparency and reproducibility, we publicly release the generated segmentations and evaluation metrics and provide interactive dashboards that allow readers to inspect individual cases and reproduce or extend our analysis. By simplifying model use, MHub$.$ai enables side-by-side benchmarking with identical execution commands and standardized outputs, and lowers the barrier to clinical translation.

cs.AI

brat: Aligned Multi-View Embeddings for Brain MRI Analysis

We present brat (brain report alignment transformer), a multi-view representation learning framework for brain magnetic resonance imaging (MRI) trained on MRIs paired with clinical reports. Brain MRIs present unique challenges due to the presence of numerous, highly varied, and often subtle abnormalities that are localized to a few slices within a 3D volume. To address these challenges, we introduce a brain MRI dataset $10\times$ larger than existing ones, containing approximately 80,000 3D scans with corresponding radiology reports, and propose a multi-view pre-training approach inspired by advances in document retrieval. We develop an implicit query-feature matching mechanism and adopt concepts from quality-diversity to obtain multi-view embeddings of MRIs that are aligned with the clinical features given by report sentences. We evaluate our approach across multiple vision-language and vision tasks, demonstrating substantial performance improvements. The brat foundation models are publicly released.

cs.CV

Quantifying uncertainty in lung cancer segmentation with foundation models applied to mixed-domain datasets

Medical image foundation models have shown the ability to segment organs and tumors with minimal fine-tuning. These models are typically evaluated on task-specific in-distribution (ID) datasets. However, reliable performance on ID datasets does not guarantee robust generalization on out-of-distribution (OOD) datasets. Importantly, once deployed for clinical use, it is impractical to have `ground truth' delineations to assess ongoing performance drifts, especially when images fall into the OOD category due to different imaging protocols. Hence, we introduced a comprehensive set of computationally fast metrics to evaluate the performance of multiple foundation models (Swin UNETR, SimMIM, iBOT, SMIT) trained with self-supervised learning (SSL). All models were fine-tuned on identical datasets for lung tumor segmentation from computed tomography (CT) scans. The evaluation was performed on two public lung cancer datasets (LRAD: n = 140, 5Rater: n = 21) with different image acquisitions and tumor stages compared to training data (n = 317 public resource with stage III-IV lung cancers) and a public non-cancer dataset containing volumetric CT scans of patients with pulmonary embolism (n = 120). All models produced similarly accurate tumor segmentation on the lung cancer testing datasets. SMIT produced the highest F1-score (LRAD: 0.60, 5Rater: 0.64) and lowest entropy (LRAD: 0.06, 5Rater: 0.12), indicating higher tumor detection rate and confident segmentations. In the OOD dataset, SMIT misdetected the least number of tumors, marked by a median volume occupancy of 5.67 cc compared to the best method SimMIM of 9.97 cc. Our analysis shows that additional metrics such as entropy and volume occupancy may help better understand model performance on mixed domain datasets.

eess.IV

Swin transformers are robust to distribution and concept drift in endoscopy-based longitudinal rectal cancer assessment

Endoscopic images are used at various stages of rectal cancer treatment starting from cancer screening, diagnosis, during treatment to assess response and toxicity from treatments such as colitis, and at follow up to detect new tumor or local regrowth (LR). However, subjective assessment is highly variable and can underestimate the degree of response in some patients, subjecting them to unnecessary surgery, or overestimate response that places patients at risk of disease spread. Advances in deep learning has shown the ability to produce consistent and objective response assessment for endoscopic images. However, methods for detecting cancers, regrowth, and monitoring response during the entire course of patient treatment and follow-up are lacking. This is because, automated diagnosis and rectal cancer response assessment requires methods that are robust to inherent imaging illumination variations and confounding conditions (blood, scope, blurring) present in endoscopy images as well as changes to the normal lumen and tumor during treatment. Hence, a hierarchical shifted window (Swin) transformer was trained to distinguish rectal cancer from normal lumen using endoscopy images. Swin as well as two convolutional (ResNet-50, WideResNet-50), and vision transformer (ViT) models were trained and evaluated on follow-up longitudinal images to detect LR on private dataset as well as on out-of-distribution (OOD) public colonoscopy datasets to detect pre/non-cancerous polyps. Color shifts were applied using optimal transport to simulate distribution shifts. Swin and ResNet models were similarly accurate in the in-distribution dataset. Swin was more accurate than other methods (follow-up: 0.84, OOD: 0.83) even when subject to color shifts (follow-up: 0.83, OOD: 0.87), indicating capability to provide robust performance for longitudinal cancer assessment.

eess.IV

Improving ovarian cancer segmentation accuracy with transformers through AI-guided labeling

Transformer models have demonstrated the capability to produce highly accurate segmentation of organs and tumors. However, model training requires high-quality curated datasets to ensure robust generalization to unseen datasets. Hence, we developed an artificial intelligence (AI) guided approach to assist with radiologist tumor delineation of partially segmented computed tomography datasets containing primary (adnexa) tumors and metastatic (omental) implants. AI guidance was implemented by training a 2D multiple resolution residual network trained with a dataset of 245 contrast-enhanced CTs with partially segmented examples. The same dataset curated through AI guidance was then used to refine two pretrained transformer models called SMIT and Swin UNETR. The models were independently tested on 71 publicly available multi-institutional 3D CT datasets. Segmentation accuracy was computed using the Dice similarity coefficient metric (DSC), average symmetric surface distance (ASSD), and the relative volume difference (RVD) metrics. Radiomic features reproducibility was assessed using the concordance correlation coefficient (CCC). Training with AI-guided segmentations significantly improved the accuracy of both SMIT (p = 6.2e-5) and Swin UNETR (p = 2e-4) models compared with using a partially delineated training dataset. Furthermore, SMIT-generated segmentations resulted in more reproducible features compared to Swin UNETR under multiple feature categories. Our results show that AI-guided data curation provides a more efficient approach to train AI models and that AI-generated segmentations can provide reproducible radiomics features.

eess.IV

Self-distilled Masked Attention guided masked image modeling with noise Regularized Teacher (SMART) for medical image analysis

Pretraining vision transformers (ViT) with attention guided masked image modeling (MIM) has shown to increase downstream accuracy for natural image analysis. Hierarchical shifted window (Swin) transformer, often used in medical image analysis cannot use attention guided masking as it lacks an explicit [CLS] token, needed for computing attention maps for selective masking. We thus enhanced Swin with semantic class attention. We developed a co-distilled Swin transformer that combines a noisy momentum updated teacher to guide selective masking for MIM. Our approach called \textsc{s}e\textsc{m}antic \textsc{a}ttention guided co-distillation with noisy teacher \textsc{r}egularized Swin \textsc{T}rans\textsc{F}ormer (SMARTFormer) was applied for analyzing 3D computed tomography datasets with lung nodules and malignant lung cancers (LC). We also analyzed the impact of semantic attention and noisy teacher on pretraining and downstream accuracy. SMARTFormer classified lesions (malignant from benign) with a high accuracy of 0.895 of 1000 nodules, predicted LC treatment response with accuracy of 0.74, and achieved high accuracies even in limited data regimes. Pretraining with semantic attention and noisy teacher improved ability to distinguish semantically meaningful structures such as organs in a unsupervised clustering task and localize abnormal structures like tumors. Code, models will be made available through GitHub upon paper acceptance.

cs.CV

Self-supervised learning improves robustness of deep learning lung tumor segmentation to CT imaging differences

Self-supervised learning (SSL) is an approach to extract useful feature representations from unlabeled data, and enable fine-tuning on downstream tasks with limited labeled examples. Self-pretraining is a SSL approach that uses the curated task dataset for both pretraining the networks and fine-tuning them. Availability of large, diverse, and uncurated public medical image sets provides the opportunity to apply SSL in the "wild" and potentially extract features robust to imaging variations. However, the benefit of wild- vs self-pretraining has not been studied for medical image analysis. In this paper, we compare robustness of wild versus self-pretrained transformer (vision transformer [ViT] and hierarchical shifted window [Swin]) models to computed tomography (CT) imaging differences for non-small cell lung cancer (NSCLC) segmentation. Wild-pretrained Swin models outperformed self-pretrained Swin for the various imaging acquisitions. ViT resulted in similar accuracy for both wild- and self-pretrained models. Masked image prediction pretext task that forces networks to learn the local structure resulted in higher accuracy compared to contrastive task that models global image information. Wild-pretrained models resulted in higher feature reuse at the lower level layers and feature differentiation close to output layer after fine-tuning. Hence, we conclude: Wild-pretrained networks were more robust to analyzed CT imaging differences for lung tumor segmentation than self-pretrained methods. Swin architecture benefited from such pretraining more than ViT.

eess.IV

Semantic Segmentation with Active Semi-Supervised Learning

Using deep learning, we now have the ability to create exceptionally good semantic segmentation systems; however, collecting the prerequisite pixel-wise annotations for training images remains expensive and time-consuming. Therefore, it would be ideal to minimize the number of human annotations needed when creating a new dataset. Here, we address this problem by proposing a novel algorithm that combines active learning and semi-supervised learning. Active learning is an approach for identifying the best unlabeled samples to annotate. While there has been work on active learning for segmentation, most methods require annotating all pixel objects in each image, rather than only the most informative regions. We argue that this is inefficient. Instead, our active learning approach aims to minimize the number of annotations per-image. Our method is enriched with semi-supervised learning, where we use pseudo labels generated with a teacher-student framework to identify image regions that help disambiguate confused classes. We also integrate mechanisms that enable better performance on imbalanced label distributions, which have not been studied previously for active learning in semantic segmentation. In experiments on the CamVid and CityScapes datasets, our method obtains over 95% of the network's performance on the full-training set using less than 17% of the training data, whereas the previous state of the art required 40% of the training data.

cs.CV

Semantic Segmentation with Active Semi-Supervised Representation Learning

Obtaining human per-pixel labels for semantic segmentation is incredibly laborious, often making labeled dataset construction prohibitively expensive. Here, we endeavor to overcome this problem with a novel algorithm that combines semi-supervised and active learning, resulting in the ability to train an effective semantic segmentation algorithm with significantly lesser labeled data. To do this, we extend the prior state-of-the-art S4AL algorithm by replacing its mean teacher approach for semi-supervised learning with a self-training approach that improves learning with noisy labels. We further boost the neural network's ability to query useful data by adding a contrastive learning head, which leads to better understanding of the objects in the scene, and hence, better queries for active learning. We evaluate our method on CamVid and CityScapes datasets, the de-facto standards for active learning for semantic segmentation. We achieve more than 95% of the network's performance on CamVid and CityScapes datasets, utilizing only 12.1% and 15.1% of the labeled data, respectively. We also benchmark our method across existing stand-alone semi-supervised learning methods on the CityScapes dataset and achieve superior performance without any bells or whistles.

cs.CV

Calibrated Vehicle Paint Signatures for Simulating Hyperspectral Imagery

We investigate a procedure for rapidly adding calibrated vehicle visible-near infrared (VNIR) paint signatures to an existing hyperspectral simulator - The Digital Imaging and Remote Sensing Image Generation (DIRSIG) model - to create more diversity in simulated urban scenes. The DIRSIG model can produce synthetic hyperspectral imagery with user-specified geometry, atmospheric conditions, and ground target spectra. To render an object pixel's spectral signature, DIRSIG uses a large database of reflectance curves for the corresponding object material and a bidirectional reflectance model to introduce s due to orientation and surface structure. However, this database contains only a few spectral curves for vehicle paints and generates new paint signatures by combining these curves internally. In this paper we demonstrate a method to rapidly generate multiple paint spectra, flying a drone carrying a pushbroom hyperspectral camera to image a university parking lot. We then process the images to convert them from the digital count space to spectral reflectance without the need of calibration panels in the scene, and port the paint signatures into DIRSIG for successful integration into the newly rendered sets of synthetic VNIR hyperspectral scenes.

eess.IV