SearcharxivSearch

arXiv subjects

Anna Bergamaschi

Publications and source records attributed to Anna Bergamaschi.

11 recordsLinked to original sources

Non-destructive 3D doping imaging of silicon sensors

Silicon sensors are the foundational detection medium for X-rays and charged particles. While their bulk dopant distribution determines device performance, it is conventionally assumed homogeneous because traditional profiling is destructive, spatially restricted, and insensitive at the relevant concentrations. Here we introduce a non-destructive 3D doping imaging technique that turns the readout electronics of a charge-integrating hybrid pixel detector into a massively parallelized capacitance-voltage profiler. With a few tens of micrometres of 3D resolution over wafer-scale areas at concentrations on the order of $10^{11}$ cm$^{-3}$, we image the bulk doping concentration of operational sensors. Macroscopically, we resolve depth-evolving concentric doping rings; microscopically, we uncover scattered doping anomalies that distort local electric fields. The rings modulate the depletion voltage, while the anomalies disrupt local charge collection, a previously overlooked cause of pixel yield and performance degradation. By bridging manufacturing signatures with microscopic defects, this approach provides a non-destructive framework for sensor characterization and yield optimization.

physics.ins-det

Sub-Pixel Electron Beam Alignment for Machine Learning Characterization of Hybrid Pixel Detectors

Due to their radiation hardness, kilohertz frame rates, and high dynamic range, hybrid pixel detectors have recently expanded their application range to electron diffraction and recently also electron imaging. However, these detectors typically have pixel sizes about ten times larger than those of direct electron detectors commonly used for imaging and more prominent electron multiple scattering effects. To overcome these limitations, machine learning approaches can be utilized to reconstruct the electron entrance point and achieve super-resolution. As this process is inherently stochastic, and machine learning relies on suitable training data, high-quality, representative training data are essential for developing models that achieve the best possible resolution. In this work, we present two novel experimental methods for generating such training data. The first method employs precise microscope alignment to scan the detector plane using a finely focused electron beam of 2 {\mu}m diameter, enabling controlled sub-pixel mapping. The second method utilizes specially designed aperture masks with sub-pixel-sized holes to accurately localize electron entry points. We developed and validated two experimental strategies for collecting training data at acceleration voltages of 60, 80, 120, and 200 keV, which enable sub-pixel labeling for hybrid pixel detectors. Notably, our methodology is broadly applicable to a wide range of hybrid pixel detectors.

physics.ins-det

High frame rate RIXS spectroscopy using a JUNGFRAU detector with an iLGAD sensor

Resonant inelastic X-ray scattering (RIXS) is a powerful photon-in, photon-out spectroscopy technique for probing electronic, magnetic, and lattice excitations in matter. Time-resolved RIXS extends this capability through a stroboscopic optical pump-probe scheme to characterize the time evolution of the photoexcitation and subsequent relaxation dynamics of a sample. This technique is, however, extremely photon-hungry, requiring high-repetition-rate and intense X-ray facilities. The Heisenberg RIXS (hRIXS) spectrometer at the Spectroscopy and Coherent Scattering (SCS) instrument of the European X-ray Free-Electron Laser (EuXFEL) is designed to exploit high-repetition-rates, while maintaining optimal time and energy resolution. In this work, we demonstrate the successful deployment of a JUNGFRAU detector equipped with an inverse Low Gain Avalanche Diode (iLGAD) sensor for time-resolved RIXS studies in the soft X-ray range, using the hRIXS spectrometer. A spatial resolution of $19.71 \pm 0.7~\mu\mathrm{m}$ and a resolving power exceeding 10,000 were achieved at an unprecedented frame rate of 47 kHz. Intra-train resolved data measured with a high FEL peak fluence of $1.8~\mathrm{mJ/cm^{2}}$ for a 928.5 eV ph photon energy and 1.1 MHz repetition rate from cupric oxide (CuO) revealed a decrease in the emitted signal by ~10% over a time interval of $340~\mu\mathrm{s}$, indicating FEL-induced effects that require monitoring when conducting high-repetition-rate experiments. These results establish the JUNGFRAU-iLGAD as a promising detector to harvest the full potential of the hRIXS spectrometer, and validate its suitability for soft X-ray applications.

physics.ins-det

Single-photon counting pixel detector for soft X-rays

Soft X-ray experiments at synchrotron light sources are essential for a wide range of research fields. However, commercially available detectors for this energy range often cannot deliver the necessary combination of quantum efficiency, signal-to-noise ratio, dynamic range, speed, and radiation hardness within a single system. While hybrid detectors have addressed these challenges effectively in the hard X-ray regime, specifically with single photon counting pixel detectors extensively used in high-performance synchrotron applications, similar solutions are desired for energies below 2 keV. In this work, we introduce the first single-photon-counting hybrid pixel detector capable of detecting X-ray energies as low as 550 eV, utilizing the internal amplification of Low-Gain Avalanche Diode (LGAD) sensors. This detector is thoroughly characterized in terms of Signal-to-Noise Ratio and Detective Quantum Efficiency. We demonstrate its capabilities through ptychographic imaging at MAX IV 4th generation synchrotron light source at the Fe L$_3$-edge (707 eV), showcasing the enhanced detection performance of the system. This development sets a new benchmark for soft X-ray applications at synchrotrons, paving the way for significant advancements in imaging and analysis at lower photon energies.

physics.ins-det

Ptychographic nanoscale imaging of the magnetoelectric coupling in freestanding BiFeO$_3$

Understanding the magnetic and ferroelectric ordering of magnetoelectric multiferroic materials at the nanoscale necessitates a versatile imaging method with high spatial resolution. Here, soft X-ray ptychography is employed to simultaneously image the ferroelectric and antiferromagnetic domains in an 80 nm thin freestanding film of the room-temperature multiferroic BiFeO$_3$ (BFO). The antiferromagnetic spin cycloid of period 64 nm is resolved by reconstructing the corresponding resonant elastic X-ray scattering in real space and visualized together with mosaic-like ferroelectric domains in a linear dichroic contrast image at the Fe L$_3$ edge. The measurements reveal a near perfect coupling between the antiferromagnetic and ferroelectric ordering by which the propagation direction of the spin cycloid is locked orthogonally to the ferroelectric polarization. In addition, the study evinces both a preference for in-plane propagation of the spin cycloid and changes of the ferroelectric polarization by 71° between multiferroic domains in the epitaxial strain-free, freestanding BFO film. The results provide a direct visualization of the strong magnetoelectric coupling in BFO and of its fine multiferroic domain structure, emphasizing the potential of ptychographic imaging for the study of multiferroics and non-collinear magnetic materials with soft X-rays.

cond-mat.mtrl-sci

Characterization of iLGADs using soft X-rays

Experiments at synchrotron radiation sources and X-ray Free-Electron Lasers in the soft X-ray energy range ($250$eV--$2$keV) stand to benefit from the adaptation of the hybrid silicon detector technology for low energy photons. Inverse Low Gain Avalanche Diode (iLGAD) sensors provide an internal gain, enhancing the signal-to-noise ratio and allowing single photon detection below $1$keV using hybrid detectors. In addition, an optimization of the entrance window of these sensors enhances their quantum efficiency (QE). In this work, the QE and the gain of a batch of different iLGAD diodes with optimized entrance windows were characterized using soft X-rays at the Surface/Interface:Microscopy beamline of the Swiss Light Source synchrotron. Above $250$eV, the QE is larger than $55\%$ for all sensor variations, while the charge collection efficiency is close to $100\%$. The average gain depends on the gain layer design of the iLGADs and increases with photon energy. A fitting procedure is introduced to extract the multiplication factor as a function of the absorption depth of X-ray photons inside the sensors. In particular, the multiplication factors for electron- and hole-triggered avalanches are estimated, corresponding to photon absorption beyond or before the gain layer, respectively.

physics.ins-det

Development of LGAD sensors with a thin entrance window for soft X-ray detection

We show the developments carried out to improve the silicon sensor technology for the detection of soft X-rays with hybrid X-ray detectors. An optimization of the entrance window technology is required to improve the quantum efficiency. The LGAD technology can be used to amplify the signal generated by the X-rays and to increase the signal-to-noise ratio, making single photon resolution in the soft X-ray energy range possible. In this paper, we report first results obtained from an LGAD sensor production with an optimized thin entrance window. Single photon detection of soft X-rays down to 452~eV has been demonstrated from measurements, with a signal-to-noise ratio better than 20.

physics.ins-det

Design and first tests of the Gotthard-II readout ASIC for the European X-ray Free-Electron Laser

Gotthard-II is a charge-integrating microstrip detector developed for experiments and diagnostics at free-electron lasers using hard X-rays of 5 keV - 20 keV. Thanks to its excellent single photon sensitivity, large dynamic range as well as high frame rate of 4.5 MHz in burst mode, its potential scientific applications include X-ray absorption/emission spectroscopy, hard X-ray high resolution single-shot spectrometry (HiREX), beam diagnostics, as well as veto signal generation for pixel detectors. The Gotthard-II ASIC has been designed and fabricated using UMC-110 nm technology. The final ASIC design and performance in terms of noise, linearity, dynamic range, coupling between channels and speed will be discussed in the paper. In addition, a first measurement of an X-ray absorption spectrum of a standard copper sample has been done. The performance of the Gotthard-II in an experiment using energy dispersive X-rays has been demonstrated.

physics.ins-det

Performance Evaluation of the Analogue Front-End and ADC Prototypes for the Gotthard-II Development

Gotthard-II is a silicon microstrip detector developed for the European X-ray Free-Electron Laser (XFEL.EU). Its potential scientific applications include X-ray absorption/emission spectroscopy, hard X-ray high resolution single-shot spectrometry (HiREX), energy dispersive experiments at 4.5 MHz frame rate, beam diagnostics, as well as veto signal generation for pixel detectors. Gotthard-II uses a silicon microstrip sensor with a pitch of 50 $μ$m or 25 $μ$m and with 1280 or 2560 channels wire-bonded to readout chips (ROCs). In the ROC, an adaptive gain switching pre-amplifier (PRE), a fully differential Correlated-Double-Sampling (CDS) stage, an Analog-to-Digital Converter (ADC) as well as a Static Random-Access Memory (SRAM) capable of storing all the 2700 images in an XFEL.EU bunch train will be implemented. Several prototypes with different designs of the analogue front-end (PRE and CDS) and ADC test structures have been fabricated in UMC-110 nm CMOS technology and their performance has been evaluated. In this paper, the performance of the analogue front-end and ADC will be summarized.

physics.ins-det

Towards Gotthard-II: Development of A Silicon Microstrip Detector for the European X-ray Free-Electron Laser

Gotthard-II is a 1-D microstrip detector specifically developed for the European X-ray Free-Electron Laser. It will not only be used in energy dispersive experiments but also as a beam diagnostic tool with additional logic to generate veto signals for the other 2-D detectors. Gotthard-II makes use of a silicon microstrip sensor with a pitch of either 50 μm or 25 μm and with 1280 or 2560 channels wire-bonded to adaptive gain switching readout chips. Built-in analog-to-digital converters and digital memories will be implemented in the readout chip for a continuous conversion and storage of frames for all bunches in the bunch train. The performance of analogue front-end prototypes of Gotthard has been investigated in this work. The results in terms of noise, conversionngain, dynamic range, obtained by means of infrared laser and X-rays, will be shown. In particular, the effects of the strip-to-strip coupling are studied in detail and it is found that the reduction of the coupling effects is one of the key factors for the development of the analogue front-end of Gotthard-II.

physics.ins-det

Regularized Multivariate Regression for Identifying Master Predictors with Application to Integrative Genomics Study of Breast Cancer

In this paper, we propose a new method remMap -- REgularized Multivariate regression for identifying MAster Predictors -- for fitting multivariate response regression models under the high-dimension-low-sample-size setting. remMap is motivated by investigating the regulatory relationships among different biological molecules based on multiple types of high dimensional genomic data. Particularly, we are interested in studying the influence of DNA copy number alterations on RNA transcript levels. For this purpose, we model the dependence of the RNA expression levels on DNA copy numbers through multivariate linear regressions and utilize proper regularizations to deal with the high dimensionality as well as to incorporate desired network structures. Criteria for selecting the tuning parameters are also discussed. The performance of the proposed method is illustrated through extensive simulation studies. Finally, remMap is applied to a breast cancer study, in which genome wide RNA transcript levels and DNA copy numbers were measured for 172 tumor samples. We identify a tran-hub region in cytoband 17q12-q21, whose amplification influences the RNA expression levels of more than 30 unlinked genes. These findings may lead to a better understanding of breast cancer pathology.

stat.AP