Searcharxiv⌕ Search

arXiv · 2610.42064

Soft X-Ray Detection Down to the Nitrogen K-Edge Using a Pixelated iLGAD Sensor

Abstract

Hybrid pixel detectors represent the state-of-the-art technology for hard X-ray experiments at synchrotron light sources and free-electron lasers, owing to their high frame rates, extended dynamic range, and scalable detection areas. However, their application in the soft X-ray regime remains bottlenecked by the challenge of developing a sensor that can achieve high quantum efficiency and an sufficient signal-to-noise ratio at low photon energies. Here, we present inverse low-gain avalanche diode (iLGAD) sensors integrated with a thin entrance window, demonstrating single-photon resolution down to 390 eV (below the Nitrogen K-edge) with a signal-to-noise ratio of 5. Two gain layer designs, standard gain layer and shallow gain layer, were systematically investigated to evaluate their spectral response as a function of photon energy and operating temperature. A double-peak feature is observed in the energy spectrum, arising from the dependence of charge multiplication on photon absorption depth. Furthermore, a phenomenological spectral fitting model was established, enabling the quantitative extraction of the effective $\mathrm{n}^+$ layer thickness and gain layer depth. Beyond providing a fundamental understanding of iLGAD charge multiplication mechanisms and characterization results in the soft X-ray regime, these findings lay the foundation for developing large-area, high-frame-rate hybrid pixel detectors for soft X-ray. This advancement directly benefits soft X-ray photon science applications, including high-resolution ptychography, spectroscopy, and resonant scattering at synchrotron and FEL beamlines.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Shuqi Li, Anna Bergamaschi, Ashish Bisht, Maurizio Boscardin, Martin Brückner, Maria Carulla, Tomáš Celko, Roberto Dinapoli, Simon Ebner, Simone Emiliani, Khalil Ferjaoui, Erik Fröjdh, Viveka Gautam, Dominic Greiffenberg, Shqipe Hasanaj, Viktoria Hinger, Marius Hürst, Vadym Kedych, Thomas King, Antonio Liguori, Carlos Lopez-Cuenca, Leonid Lunin, Alice Mazzoleni, Davide Mezza, Scharon Moses, Konstantinos Moustakas, Aldo Mozzanica, Jonathan Mulvey, Martin Müller, Giovanni Paternoster, Christian Ruder, Bernd Schmitt, Saverio Silletta, Dhanya Thattil, Matteo Centis Vignali, Xiangyu Xie, Jiaguo Zhang, Sinuo Zhang. 2026-10-30. Soft X-Ray Detection Down to the Nitrogen K-Edge Using a Pixelated iLGAD Sensor. https://arxiv.org/abs/2610.42064

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Positron Emission Tomography with quantum-entangled Compton events: first imaging results at clinically relevant activities

In Positron Emission Tomography, a potential, yet unutilized enhancement, may come from exploiting the quantum entanglement of the annihilation quanta, inscribed in the correlation of their polarizations. To investigate this, we built a PET demonstrator capable of measuring polarization correlations of annihilation quanta by their Compton scattering, based on single-layer scintillator polarimeters. We present a detailed study of the imaging of two $^{68}$Ge line sources, 45 MBq each, to extract the spatial resolution and assess image quality. The results show that a spatial resolution of 2.5$\pm$0.1 mm is obtained using single-pixel events, while resolutions obtained with polarization-correlated Compton events range from 3.6$\pm$0.3 mm to 4.9$\pm$0.3 mm, depending on data selection criteria. We also found that the polarization-correlated Compton events exhibit up to 20% higher average signal to random background ratio compared to the single-pixel events. We also present the first imaging of the NEMA NU-4 phantom filled with a $^{68}$Ga solution of 378 MBq initial activity, successfully combining polarization-correlated events with conventional single-pixel event selection. Based on the extracted spatial resolution, signal-to-background, signal-to-noise, contrast, and contrast-to-noise ratio, we estimate that up to 10% sensitivity increase may be attained by exploiting the polarization-correlated events, while preserving a high image quality.

physics.ins-det↗

Characterization of immersed SiPM arrays in liquid scintillator between room temperature and $-30\,^{\circ}\mathrm{C}$

Liquid scintillator detectors instrumented with distributed silicon photomultiplier (SiPM) arrays can be used in compact, topology-sensitive, and low-background experiments, but the temperature dependence of SiPMs immersed directly in the scintillation medium has not been widely characterized. We report the operation of a 125-liter linear-alkylbenzene-based liquid scintillator detector read out by 125 SiPM channels immersed in the active volume, over the range from room temperature to $-30\,^{\circ}\mathrm{C}$. The detector response was measured with cosmic-ray muons, including stopping muons followed by their Michel-electron decay. Cooling from $+15\,^{\circ}\mathrm{C}$ to $-30\,^{\circ}\mathrm{C}$ reduced the SiPM dark-count rate by a factor of 13.5, increased the single-photoelectron response by 49.1%, and increased the cosmic-ray muon light yield by 16.7%. The improved photoelectron separation and baseline stability at low temperature enabled a selection of stopping-muon events, from which the effective muon lifetime was measured to be $1959\pm132\,\mathrm{ns}$, consistent with the value expected for a hydrocarbon scintillator once $μ^{-}$ capture on carbon is taken into account.

physics.ins-det↗

Residual AM and PM Noise of Selected X-Band Amplifiers

In microwave systems design, amplitude modulation (AM) noise is often ignored relative to phase modulation (PM) noise. However, in high-performance applications requiring ultra-low PM noise, AM noise becomes a critical limiting factor due to AM-to-PM conversion mechanisms. Because AM noise specifications are rarely, if ever, provided for commercial microwave components, this study characterizes the residual AM and PM noise of several 10 GHz amplifiers. We present performance data for various Heterojunction Bipolar Transistor (HBT) amplifier designs and demonstrate the noise reduction achieved through power-summed configurations. For example, a discrete-die GaAs HBT amplifier achieves residual PM noise below $-160$ dBrad$^2$/Hz and AM noise of approximately $-155$ dB/Hz at a 1 kHz offset in a quad power-summed configuration. A notable finding is that the majority of amplifier designs surveyed in this study exhibit higher AM noise relative to their PM noise, with only a few exceptions. The impact of bias supply quality on residual noise is also quantified, demonstrating that the choice of voltage regulator is a first-order design parameter below 1 kHz offset.

physics.ins-det↗