SearcharxivSearch

arXiv subjects

Anne Dabrowski

Publications and source records attributed to Anne Dabrowski.

4 recordsLinked to original sources

Design and performance of the Fast Beam Condition Monitor for luminosity and background measurement at the CMS Experiment in LHC Run 3

The Fast Beam Condition Monitor (BCM1F) has been used at the CMS Experiment since the first LHC circulating beams in 2008. Originally meant as a beam-induced background monitor for fast beam losses detection, it showed a potential also for luminosity measurements in 2012 running, and has been used for luminosity measurements since the beginning of Run 2 data taking in 2015 as a part of the Beam Radiation, Instrumentation and Luminosity (BRIL) system. Over the years, the system has undergone various upgrades to the sensors, the front-end and back-end electronics, providing improvements in the precision of the measurements, that remain valid in the higher pileup conditions of LHC Run 3 (2022-2026). Based on the experience of all BCM1F Run 2 upgrades, the detector was completely rebuilt prior to LHC Run 3 using AC-coupled silicon-pad diodes and active cooling. This latest detector version exhibits excellent linearity with instantaneous luminosity and achieves nanosecond-level timing precision, enabling improved systematic corrections for luminosity and background measurements. This paper presents a detailed overview of the detector system for LHC Run 3, including the selection and qualification of sensors as well as a summary of the readout system. It also outlines the processing and calibration strategy for luminosity data, discussing operational hurdles and comparing BCM1F measurements to other CMS luminosity measurements to assess the system's performance as a luminometer. Lastly, the implications for the design of a future luminosity detector to be used in the envisioned HL-LHC upgrade are discussed.

physics.ins-det

Description of radiation damage in diamond sensors using an effective defect model

The BCML system is a beam monitoring device in the CMS experiment at the LHC. As detectors poly-crystalline diamond sensors are used. Here high particle rates occur from the colliding beams scattering particles outside the beam pipe. These particles cause defects, which act as traps for the ionization, thus reducing the CCE. However, the loss in CCE was much more severe than expected. The reason why in real experiments the CCE is so much worse than in laboratory experiments is related to the rate of incident particles. At high particle rates the trapping rate of the ionization is so high compared with the detrapping rate, that space charge builds up. This space charge reduces locally the internal electric field, which in turn increases the trapping rate and hence reduces the CCE even further. In order to connect these macroscopic measurements with the microscopic defects acting as traps for the ionization charge the TCAD simulation program SILVACO was used. Two effective acceptor and donor levels were needed to fit the data. Using this effective defect model the highly non- linear rate dependent diamond polarization as function of the particle rate environment and the resulting signal loss could be simulated.

physics.ins-det

Severe signal loss in diamond beam loss monitors in high particle rate environments by charge trapping in radiation-induced defects

The beam condition monitoring leakage (BCML) system is a beam monitoring device in the compact muon solenoid (CMS) experiment at the large hadron collider (LHC). As detectors 32 poly-crystalline (pCVD) diamond sensors are positioned in rings around the beam pipe. Here, high particle rates occur from the colliding beams scattering particles outside the beam pipe. These particles cause defects, which act as traps for the ionization, thus reducing the charge collection efficiency (CCE). However, the loss in CCE was much more severe than expected from low rate laboratory measurements and simulations, especially in single-crystalline (sCVD) diamonds, which have a low initial concentration of defects. The reason why in real experiments the CCE is much worse than in laboratory experiments is related to the ionization rate. At high particle rates the trapping rate of the ionization is so high compared with the detrapping rate, that space charge builds up. This space charge reduces locally the internal electric field, which in turn increases the trapping rate and recombination and hence reduces the CCE in a strongly non-linear way. A diamond irradiation campaign was started to investigate the rate dependent electrical field deformation with respect to the radiation damage. Besides the electrical field measurements via the Transient Current Technique (TCT), the CCE was measured. The experimental results were used to create an effective deep trap model that takes the radiation damage into account. Using this trap model the rate dependent electrical field deformation and the CCE were simulated with the software SILVACO TCAD. The simulation, tuned to rate dependent measurements from a strong radioactive source, was able to predict the non-linear decrease of the CCE in the harsh environment of the LHC, where the particle rate was a factor 30 higher.

physics.ins-det

Fast Beam Condition Monitor for CMS: performance and upgrade

The CMS beam and radiation monitoring subsystem BCM1F (Fast Beam Condition Monitor) consists of 8 individual diamond sensors situated around the beam pipe within the pixel detector volume, for the purpose of fast bunch-by-bunch monitoring of beam background and collision products. In addition, effort is ongoing to use BCM1F as an online luminosity monitor. BCM1F will be running whenever there is beam in LHC, and its data acquisition is independent from the data acquisition of the CMS detector, hence it delivers luminosity even when CMS is not taking data. A report is given on the performance of BCM1F during LHC run I, including results of the van der Meer scan and on-line luminosity monitoring done in 2012. In order to match the requirements due to higher luminosity and 25 ns bunch spacing, several changes to the system must be implemented during the upcoming shutdown, including upgraded electronics and precise gain monitoring. First results from Run II preparation are shown.

physics.ins-det