SearcharxivSearch

arXiv subjects

Athanasios Diamantopoulos

Publications and source records attributed to Athanasios Diamantopoulos.

2 recordsLinked to original sources

Real-time 3D Ultrasonic Needle Tracking with a Photoacoustic Beacon

Many minimally invasive procedures, such as core needle biopsy of focal liver lesions, nerve blocks, and fetal and vascular interventions, are typically performed under ultrasound guidance, which provides real-time, high-resolution visualisation of tissue anatomy. Accurate and efficient localisation of the needle tip relative to patient anatomy is essential for guiding the needle towards the procedure target, avoiding adverse events and reducing the need for repeat procedures. However, the 3D nature of the procedure and poor image contrast of the needle in heterogeneous tissue or at steep insertion angles often lead to confusion over the true location of the tip within the 2D guidance images, and existing methods to enhance needle visibility largely remain limited to 2D. Here, we present a novel interventional ultrasound system capable of 2D B-mode imaging and 3D needle tracking. The tip location is determined from the time-of-flight of ultrasound generated by a photoacoustic beacon embedded in the needle bevel and received by a sparse receiver array distributed around the imaging system's curvilinear ultrasound probe. The measured tracking accuracy was better than 2 mm for depths up to 140 mm in water, and approximately 2 mm on average in an ex vivo tissue phantom, with referenced positions derived from X-ray computed tomography. In a usability study involving 12 clinicians performing biopsy procedures in a ex vivo tissue phantom, the failure rate was reduced by 35%, from 15.8% to 10.3% after only a few minutes of training. These results demonstrate that the proposed system has strong potential to support a wide range of minimally invasive procedures by enabling clinicians to accurately target small anatomical structures, improving the efficiency and effectiveness of diagnostic sampling and therapeutic delivery or ablation, and reducing the risk of adverse events.

physics.med-ph

Volumetric ultrasound imaging with a sparse matrix array and integrated fiber-optic sensing for robust needle tracking in interventional procedures

Accurate visualization of interventional devices, such as medical needles, is essential for the safe and effective guidance of minimally invasive procedures. Ultrasound (US) imaging is widely used for needle guidance, but the two-dimensional nature of most clinical probes limits accurate three-dimensional (3D) localization, particularly of the needle tip. We present a novel system that integrates volumetric US imaging with 3D needle tracking by combining a fiber-optic hydrophone embedded in the needle and a sparse spiral US array. Real-time volumetric imaging was achieved using plane-wave techniques, while precise needle tip tracking was enabled through communication between the probe and hydrophone. The feasibility of the approach was demonstrated using a nerve block training phantom. This proof-of-concept system enables simultaneous volumetric anatomical imaging and 3D needle tip tracking, with strong potential to enhance the efficacy and safety of image-guided interventional procedures.

physics.med-ph