SearcharxivSearch

arXiv subjects

Atsuko K. Ichikawa

Publications and source records attributed to Atsuko K. Ichikawa.

4 recordsLinked to original sources

Semiautomatic dimensional screening of plastic scintillator cubes using image analysis and robotics

Large-scale particle physics detectors often contain millions of repeated components, making precise and efficient quality control essential. We have developed a semiautomatic system for dimensional screening of 1 cm$^3$ plastic scintillator cubes for their potential use in future neutrino detectors. The system employs a motorized rotating stage, six high-resolution cameras, and image analysis software to measure cube size, surface protrusions, and the positions of holes for wavelength-shifting fibers used in optical readout. Based on these measurements, each cube is automatically classified as either acceptable or defective. We constructed and validated a prototype system, achieving a measurement precision of 10 $μ$m and over 80% consistency with manual screening. To enable classification of cubes into 48 groups based on hole positions while preserving their orientation, we introduced a 6-axis robotic arm. The completed system achieved a rejection rate of 3.1%. Our approach contributes to scalable, precise, and efficient quality control for future large-scale particle physics detectors.

physics.ins-det

In-situ high voltage generation with Cockcroft-Walton multiplier for xenon gas time projection chamber

We have newly developed a Cockcroft-Walton (CW) multiplier that can be used in a gas time projection chamber (TPC). A TPC requires a high voltage to form an electric field that drifts ionization electrons. Supplying the high voltage from outside the pressure vessel requires a dedicated high-voltage feedthrough. An alternative approach is to generate the high voltage inside the pressure vessel with a relatively low voltage introduced from outside. A CW multiplier can convert a low AC voltage input to a high DC voltage output, making it suitable for this purpose. We have integrated a CW multiplier into the AXEL (A Xenon ElectroLuminescence detector), a high pressure xenon gas TPC to search for neutrinoless double beta decay of $^{136}$Xe. It uses silicon photomultipliers to detect the ionization electrons through elecrtoluminescence, making it strong against electronic noise. Operation of the CW multiplier was successfully demonstrated; the TPC was operated for 40 days at 6.8 bar, and an energy resolution as high as (0.67 $\pm$ 0.08) % (FWHM) at 2615 keV was obtained.

physics.ins-det

Performance evaluation of electron multiplier tubes as a high-intensity muon beam monitor of accelerator neutrino experiments

Upgrade work towards increasing the beam intensity of the neutrino beamline at J- PARC is underway. Monitoring tertiary muon beams is essential for stable operation of the beamline. Accordingly, we plan to replace the present muon monitor sensors with electron multiplier tubes (EMTs). We investigated the radiation tolerance and linearity response of EMTs using a 90 MeV electron beam. An EMTs was irradiated with electrons up to 470 nC. EMTs show higher radiation tolerance than the Si sensors which are presently used as one of the muon monitor detectors for the T2K long-baseline neutrino experiment at J-PARC. The integrated charge yield decrease is found to be less than 8% after a beam irradiation equivalent to 132 days of operation at the future J-PARC beam power of 1.3 MW. The EMTs show linearity better than $\pm$5% up to the future beam intensity. The observed yield decrease is likely due to dynode deterioration based on the detailed investigation. The studies described here confirm that EMTs can be used as a high-intensity muon beam monitor. From the reported results, we are proceeding with the installation in the J-PARC neutrino beamline.

physics.ins-det

High-pressure xenon gas time projection chamber with scalable design and its performance at around the Q value of $^{136}$Xe double-beta decay

We have been developing a high-pressure xenon gas time projection chamber (TPC) to search for neutrinoless double beta ($0νββ$) decay of $^{136}$Xe. The unique feature of this TPC is in the detection part of ionization electrons, called ELCC. ELCC is composed of multiple units, and one unit covers 48.5 $\mathrm{cm}^2$. A 180 L size prototype detector with 12 units, 672 channels, of ELCC was constructed and operated with 7.6 bar natural xenon gas to evaluate the performance of the detector at around the Q value of $^{136}$Xe $0νββ$. The obtained FWHM energy resolution is (0.73 $\pm$ 0.11) % at 1836 keV. This corresponds to (0.60 $\pm$ 0.03) % to (0.70 $\pm$ 0.21) % of energy resolution at the Q value of $^{136}Xe$ $0νββ$. This result shows the scalability of the AXEL detector with ELCC while maintaining high energy resolution. Factors determining the energy resolution were quantitatively evaluated and the result indicates further improvement is feasible. Reconstructed track images show distinctive structures at the endpoint of electron tracks, which will be an important feature to distinguish $0νββ$ signals from gamma-ray backgrounds.

physics.ins-det