SearcharxivSearch

arXiv · 2501.08554

In-situ high voltage generation with Cockcroft-Walton multiplier for xenon gas time projection chamber

Abstract

We have newly developed a Cockcroft-Walton (CW) multiplier that can be used in a gas time projection chamber (TPC). A TPC requires a high voltage to form an electric field that drifts ionization electrons. Supplying the high voltage from outside the pressure vessel requires a dedicated high-voltage feedthrough. An alternative approach is to generate the high voltage inside the pressure vessel with a relatively low voltage introduced from outside. A CW multiplier can convert a low AC voltage input to a high DC voltage output, making it suitable for this purpose. We have integrated a CW multiplier into the AXEL (A Xenon ElectroLuminescence detector), a high pressure xenon gas TPC to search for neutrinoless double beta decay of $^{136}$Xe. It uses silicon photomultipliers to detect the ionization electrons through elecrtoluminescence, making it strong against electronic noise. Operation of the CW multiplier was successfully demonstrated; the TPC was operated for 40 days at 6.8 bar, and an energy resolution as high as (0.67 $\pm$ 0.08) % (FWHM) at 2615 keV was obtained.

Explore related subjects

Keep this discovery

BibTeXRIS

Shinichi Akiyama, Junya Hikida, Masashi Yoshida, Kazuhiro Nakamura, Sei Ban, Masanori Hirose, Atsuko K. Ichikawa, Yoshihisa Iwashita, Tatsuya Kikawa, Yasuhiro Nakajima, Kiseki D. Nakamura, Tsuyoshi Nakaya, Shuhei Obara, Ken Sakashita, Hiroyuki Sekiya, Bungo Sugashima, Soki Urano, Sota Hatsumi, Sota Kobayashi, Hayato Sasaki. 2025-01-15. In-situ high voltage generation with Cockcroft-Walton multiplier for xenon gas time projection chamber. https://doi.org/10.1093/ptep/ptaf066

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det