Searcharxiv⌕ Search

arXiv subjects

B. J. van Wees

Publications and source records attributed to B. J. van Wees.

At least 37 records · Page 2Linked to original sources

Efficient injection and detection of out-of-plane spins via the anomalous spin Hall effect in permalloy nanowires

We report a novel mechanism for the electrical injection and detection of out-of-plane spin accumulation via the anomalous spin Hall effect (ASHE), where the direction of the spin accumulation can be controlled by manipulating the magnetization of the ferromagnet. This mechanism is distinct from the spin Hall effect (SHE), where the spin accumulation is created along a fixed direction parallel to an interface. We demonstrate this unique property of the ASHE in nanowires made of permalloy (Py), to inject and detect out-of-plane spin accumulation in a magnetic insulator, yttrium iron garnet (YIG). We show that the efficiency for the injection/detection of out-of-plane spins can be up to 50% of that of in-plane spins. We further report the possibility to detect spin currents parallel to the Py/YIG interface for spins fully oriented in the out-of-plane direction, resulting in a sign reversal of the non-local magnon spin signal. The new mechanisms that we have demonstrated are highly relevant for spin torque devices and applications.

cond-mat.mes-hall↗

Criteria for accurate determination of the magnon relaxation length from the nonlocal spin Seebeck effect

The nonlocal transport of thermally generated magnons not only unveils the underlying mechanism of the spin Seebeck effect, but also allows for the extraction of the magnon relaxation length ($λ_m$) in a magnetic material, the average distance over which thermal magnons can propagate. In this study, we experimentally explore in yttrium iron garnet (YIG)/platinum systems much further ranges compared with previous investigations. We observe that the nonlocal SSE signals at long distances ($d$) clearly deviate from a typical exponential decay. Instead, they can be dominated by the nonlocal generation of magnon accumulation as a result of the temperature gradient present away from the heater, and decay geometrically as $1/d^2$. We emphasize the importance of looking only into the exponential regime (i.e., the intermediate distance regime) to extract $λ_m$. With this principle, we study $λ_m$ as a function of temperature in two YIG films which are 2.7 and 50 $μ$m in thickness, respectively. We find $λ_m$ to be around 15 $μ$m at room temperature and it increases to 40 $μ$m at $T=$ 3.5 K. Finite element modeling results agree with experimental studies qualitatively, showing also a geometrical decay beyond the exponential regime. Based on both experimental and modeling results we put forward a general guideline for extracting $λ_m$ from the nonlocal spin Seebeck effect.

cond-mat.mtrl-sci↗

Spin Injection and Detection via the Anomalous Spin Hall Effect in a Ferromagnetic Metal

We report a novel spin injection and detection mechanism via the anomalous Hall effect in a ferromagnetic metal. The anomalous spin Hall effect (ASHE) refers to the transverse spin current generated within the ferromagnet. We utilize the ASHE and its reciprocal effect to electrically inject and detect magnons in a magnetic insulator in a non-local geometry. Our experiments reveal that permalloy can have a higher spin injection and detection efficiency to that of platinum, owing to the ASHE. We also demonstrate the tunability of the ASHE via the orientation of the permalloy magnetization, thus creating new possibilities for spintronic applications.

cond-mat.mes-hall↗

Nonlocal magnon-polaron transport in yttrium iron garnet

The spin Seebeck effect (SSE) is observed in magnetic insulator|heavy metal bilayers as an inverse spin Hall effect voltage under a temperature gradient. The SSE can be detected nonlocally as well, viz. in terms of the voltage in a second metallic contact (detector) on the magnetic film, spatially separated from the first contact that is used to apply the temperature bias (injector). Magnon-polarons are hybridized lattice and spin waves in magnetic materials, generated by the magnetoelastic interaction. Kikkawa et al. [Phys. Rev. Lett. \textbf{117}, 207203 (2016)] interpreted a resonant enhancement of the local SSE in yttrium iron garnet (YIG) as a function of the magnetic field in terms of magnon-polaron formation. Here we report the observation of magnon-polarons in \emph{nonlocal} magnon spin injection/detection devices for various injector-detector spacings and sample temperatures. Unexpectedly, we find that the magnon-polaron resonances can suppress rather than enhance the nonlocal SSE. Using finite element modelling we explain our observations as a competition between the SSE and spin diffusion in YIG. These results give unprecedented insights into the magnon-phonon interaction in a key magnetic material.

cond-mat.mes-hall↗

Nonlocal magnon spin transport in NiFe$_2$O$_4$ thin films

We report magnon spin transport in nickel ferrite (NiFe$_2$O$_4$, NFO)/ platinum (Pt) bilayer systems at room temperature. A nonlocal geometry is employed, where the magnons are excited by the spin Hall effect or by the Joule heating induced spin Seebeck effect at the Pt injector, and detected at a certain distance away by the inverse spin Hall effect at the Pt detector. The dependence of the nonlocal magnon spin signals as a function of the magnetic field is closely related to the NFO magnetization behavior. In contrast, we observe that the magnetoresistance measured locally at the Pt injector does not show a clear relation with the average NFO magnetization. We estimate the magnon spin relaxation length to be 3.1 $\pm$ 0.2 $μ$m in the investigated NFO samples.

cond-mat.mtrl-sci↗

Spin relaxation 1/f noise in graphene

We report the first measurement of 1/f type noise associated with electronic spin transport, using single layer graphene as a prototypical material with a large and tunable Hooge parameter. We identify the presence of two contributions to the measured spin-dependent noise: contact polarization noise from the ferromagnetic electrodes, which can be filtered out using the cross-correlation method, and the noise originated from the spin relaxation processes. The noise magnitude for spin and charge transport differs by three orders of magnitude, implying different scattering mechanisms for the 1/f fluctuations in the charge and spin transport processes. A modulation of the spin-dependent noise magnitude by changing the spin relaxation length and time indicates that the spin-flip processes dominate the spin-dependent noise.

cond-mat.mes-hall↗

Magnon Planar Hall Effect and Anisotropic Magnetoresistance in a Magnetic Insulator

Electrical resistivities can be different for charge currents travelling parallel or perpendicular to the magnetization in magnetically ordered conductors or semiconductors, resulting in the well-known planar Hall effect and anisotropic magnetoresistance. Here, we study the analogous anisotropic magnetotransport behavior for magnons in a magnetic insulator Y$_{3}$Fe$_{5}$O$_{12}$. Electrical and thermal magnon injection, and electrical detection methods are used at room temperature with transverse and longitudinal geometries to measure the magnon planar Hall effect and anisotropic magnetoresistance, respectively. We observe that the relative difference between magnon current conductivities parallel and perpendicular to the magnetization, with respect to the average magnon conductivity, i.e. $|(σ_{\parallel}^{\textrm{m}}-σ_{\perp}^{\textrm{m}})/σ_{0}^{\textrm{m}}|$ , is approximately 5% with the majority of the measured devices showing $σ_{\perp}^{\textrm{m}}>σ_{\parallel}^{\textrm{m}}$.

cond-mat.mes-hall↗

Anisotropic Hanle lineshape via anisotropic magnetothermoelectric phenomena

We observe anisotropic Hanle lineshape with unequal in-plane and out-of-plane non-local signals for spin precession measurements carried out on lateral metallic spin valves with transparent interfaces. The conventional interpretation for this anisotropy corresponds to unequal spin relaxation times for in-plane and out-of-plane spin orientations as for the case of 2D materials like graphene, but it is unexpected in a polycrystalline metallic channel. Systematic measurements as a function of temperature and channel length, combined with both analytical and numerical thermoelectric transport models, demonstrate that the anisotropy in the Hanle lineshape is magneto-thermal in origin, caused by the anisotropic modulation of the Peltier and Seebeck coefficients of the ferromagnetic electrodes. Our results call for the consideration of such magnetothermoelectric effects in the study of anisotropic spin relaxation.

cond-mat.mes-hall↗

Probing current-induced magnetic fields in Au|YIG heterostructure with low-energy muon spectroscopy

We investigated the depth dependence of current-induced magnetic fields in a bilayer of a normal metal (Au) and a ferrimagnetic insulator (Yttrium Iron Garnet - YIG) by using low energy muon spectroscopy (LE-muSR). This allows us to explore how these fields vary from the Au surface down to the buried Au|YIG interface, which is relevant to study physics like the spin-Hall effect. We observed a maximum shift of 0.4 G in the internal field of muons at the surface of Au film which is in close agreement to the value expected for Oersted fields. As muons are implanted closer to the Au|YIG interface the shift is strongly suppressed, which we attribute to the dipolar fields present at the Au|YIG interface. Combining our measurements with modelling, we show that dipolar fields caused by the finite roughness of the Au|YIG interface consistently explains our observations. Our results, therefore, gauge the limits on the spatial resolution and the sensitivity of LE-muSR to the roughness of the buried magnetic interfaces, a prerequisite for future studies addressing current induced fields caused by the spin-Hall effect.

cond-mat.mtrl-sci↗

Electrical detection of spiral spin structures in Pt|Cu_2OSeO_3 heterostructures

The interaction between the itinerant spins in metals and localized spins in magnetic insulators thus far has only been explored in collinear spin systems, such as garnets. Here, we report the spin-Hall magnetoresistance (SMR) sensitive to the surface magnetization of the spin-spiral material, Cu_2OSeO_3. We experimentally demonstrate that the angular dependence of the SMR changes drastically at the transition between the helical spiral and the conical spiral phases. Furthermore, the sign and magnitude of the SMR in the conical spiral state are controlled by the cone angle. We show that this complex behaviour can be qualitatively explained within the SMR theory initially developed for collinear magnets. In addition, we studied the spin Seebeck effect (SSE), which is sensitive to the bulk magnetization. It originates from the conversion of thermally excited low-energy spin waves in the magnet, known as magnons, into the spin current in the adjacent metal contact (Pt). The SSE displays unconventional behavior where not only the magnitude but also the phase of the SSE vary with the applied magnetic field.

cond-mat.mtrl-sci↗

Direct electronic measurement of Peltier cooling and heating in graphene

Thermoelectric effects allow the generation of electrical power from waste heat and the electrical control of cooling and heating. Remarkably, these effects are also highly sensitive to the asymmetry in the density of states around the Fermi energy and can therefore be exploited as probes of distortions in the electronic structure at the nanoscale. Here we consider two-dimensional graphene as an excellent nanoscale carbon material for exploring the interaction between electronic and thermal transport phenomena, by presenting a direct and quantitative measurement of the Peltier component to electronic cooling and heating in graphene. Thanks to an architecture including nanoscale thermometers, we detected Peltier component modulation of up to 15 mK for currents of 20 $μ$A at room temperature and observed a full reversal between Peltier cooling and heating for electron and hole regimes. This fundamental thermodynamic property is a complementary tool for the study of nanoscale thermoelectric transport in two-dimensional materials.

cond-mat.mes-hall↗

Spin transport in fully hexagonal boron nitride encapsulated graphene

We study fully hexagonal boron nitride (hBN)-encapsulated graphene spin valve devices at room temperature. The device consists of a graphene channel encapsulated between two crystalline hBN flakes; thick-hBN flake as a bottom gate dielectric substrate which masks the charge impurities from SiO2/Si substrate and single-layer thin-hBN flake as a tunnel barrier. Full encapsulation prevents the graphene from coming in contact with any polymer/chemical during the lithography and thus gives homogeneous charge and spin transport properties across different regions of the encapsulated graphene. Further, even with the multiple electrodes in between the injection and the detection electrodes which are in conductivity mismatch regime, we observe spin transport over 12.5 um long distance under the thin-hBN encapsulated graphene channel, demonstrating the clean interface and the pin-hole free nature of the thin-hBN as an efficient tunnel barrier.

cond-mat.mes-hall↗

Proximity induced room-temperature ferromagnetism in graphene probed with spin currents

The introduction and control of ferromagnetism in graphene opens up a range of new directions for fundamental and applied studies. Several approaches have been pursued so far, such as introduction of defects, functionalization with adatoms, and shaping of graphene into nanoribbons with well-defined zigzag edges. A more robust and less invasive method utilizes the introduction of an exchange interaction by a ferromagnetic insulator in proximity with graphene. Here we present a direct measurement of the exchange interaction in room temperature ferromagnetic graphene. We study the spin transport in exfoliated graphene on a yttrium-iron-garnet substrate where the observed spin precession clearly indicates the presence and strength of an exchange field that is an unambiguous evidence of induced ferromagnetism. We describe the results with a modified Bloch diffusion equation and extract an average exchange field of the order of 0.2 T. Further, we demonstrate that a proximity induced 2D ferromagnet can efficiently modulate a spin current by controlling the direction of the exchange field. These results can create a building block for magnetic-gate tuneable spin transport in one-atom-thick spintronic devices.

cond-mat.mes-hall↗

Magnetic field dependence of the magnon spin diffusion length in the magnetic insulator yttrium iron garnet

We investigated the effect of an external magnetic field on the diffusive spin transport by magnons in the magnetic insulator yttrium iron garnet (YIG), using a non-local magnon transport measurement geometry. We observed a decrease in magnon spin diffusion length $λ_m$ for increasing field strengths, where $λ_m$ is reduced from 9.6$\pm1.2$ $μ$m at 10 mT to 4.2$\pm0.6$ $μ$m at 3.5 T at room temperature. In addition, we find that there must be at least one additional transport parameter that depends on the external magnetic field. Our results do not allow us to unambiguously determine whether this is the magnon equilibrium density or the magnon diffusion constant. These results are significant for experiments in the more conventional longitudinal spin Seebeck geometry, since the magnon spin diffusion length sets the length scale for the spin Seebeck effect as well and is relevant for its understanding.

cond-mat.mes-hall↗

Towards the understanding of the origin of charge-current-induced spin voltage signals in the topological insulator Bi$_2$Se$_3$

Topological insulators provide a new platform for spintronics due to the spin texture of the surface states that are topologically robust against elastic backscattering. Here, we report on an investigation of the measured voltage obtained from efforts to electrically probe spin-momentum locking in the topological insulator Bi$_2$Se$_3$ using ferromagnetic contacts. Upon inverting the magnetization of the ferromagnetic contacts, we find a reversal of the measured voltage. Extensive analysis of the bias and temperature dependence of this voltage was done, considering the orientation of the magnetization relative to the current. Our findings indicate that the measured voltage can arise due to fringe-field-induced Hall voltages, different from current-induced spin polarization of the surface state charge carriers, as reported recently. Understanding the nontrivial origin of the measured voltage is important for realizing spintronic devices with topological insulators.

cond-mat.mes-hall↗

Spin Relaxation in Graphene with self-assembled Cobalt Porphyrin Molecules

In graphene spintronics, interaction of localized magnetic moments with the electron spins paves a new way to explore the underlying spin relaxation mechanism. A self-assembled layer of organic cobalt-porphyrin (CoPP) molecules on graphene provides a desired platform for such studies via the magnetic moments of porphyrin-bound cobalt atoms. In this work a study of spin transport properties of graphene spin-valve devices functionalized with such CoPP molecules as a function of temperature via non-local spin-valve and Hanle spin precession measurements is reported. For the functionalized (molecular) devices, we observe a slight decrease in the spin relaxation time (τs), which could be an indication of enhanced spin-flip scattering of the electron spins in graphene in the presence of the molecular magnetic moments. The effect of the molecular layer is masked for low quality samples (low mobility), possibly due to dominance of Elliot-Yafet (EY) type spin relaxation mechanisms.

cond-mat.mes-hall↗

Comparison of the magneto-Peltier and magneto-Seebeck effects in magnetic tunnel junctions

Understanding heat generation and transport processes in a magnetic tunnel junction (MTJ) is a significant step towards improving its application in current memory devices. Recent work has experimentally demonstrated the magneto-Seebeck effect in MTJs, where the Seebeck coefficient of the junction varies as the magnetic configuration changes from a parallel (P) to an anti-parallel (AP) configuration. Here we report the study on its as-yet-unexplored reciprocal effect, the magneto-Peltier effect, where the heat flow carried by the tunneling electrons is altered by changing the magnetic configuration of the MTJ. The magneto-Peltier signal that reflects the change in the temperature difference across the junction between the P and AP configurations scales linearly with the applied current in the small bias but is greatly enhanced in the large bias regime, due to higher-order Joule heating mechanisms. By carefully extracting the linear response which reflects the magneto-Peltier effect, and comparing it with the magneto-Seebeck measurements performed on the same device, we observe results consistent with Onsager reciprocity. We estimate a magneto-Peltier coefficient of 13.4 mV in the linear regime using a three-dimensional thermoelectric model. Our result opens up the possibility of programmable thermoelectric devices based on the Peltier effect in MTJs.

cond-mat.mes-hall↗

Control of spin current by a magnetic YIG substrate in NiFe/Al nonlocal spin valves

We study the effect of a magnetic insulator (Yttrium Iron Garnet - YIG) substrate on the spin transport properties of Ni$_{80}$Fe$_{20}$/Al nonlocal spin valve (NLSV) devices. The NLSV signal on the YIG substrate is about 2 to 3 times lower than that on a non magnetic SiO$_2$ substrate, indicating that a significant fraction of the spin-current is absorbed at the Al/YIG interface. By measuring the NLSV signal for varying injector-to-detector distance and using a three dimensional spin-transport model that takes spin current absorption at the Al/YIG interface into account we obtain an effective spin-mixing conductance $G_{\uparrow\downarrow}\simeq 5 - 8\times 10^{13}~Ω^{-1}$m$^{-2}$. We also observe a small but clear modulation of the NLSV signal when rotating the YIG magnetization direction with respect to the fixed spin polarization of the spin accumulation in the Al. Spin relaxation due to thermal magnons or roughness of the YIG surface may be responsible for the observed small modulation of the NLSV signal.

cond-mat.mes-hall↗