Searcharxiv⌕ Search

arXiv subjects

B. Morgan

Publications and source records attributed to B. Morgan.

At least 37 records · Page 2Linked to original sources

Result of the search for neutrinoless double-$β$ decay in $^{100}$Mo with the NEMO-3 experiment

The NEMO-3 detector, which had been operating in the Modane Underground Laboratory from 2003 to 2010, was designed to search for neutrinoless double $β$ ($0νββ$) decay. We report final results of a search for $0νββ$ decays with $6.914$ kg of $^{100}$Mo using the entire NEMO-3 data set with a detector live time of $4.96$ yr, which corresponds to an exposure of 34.3 kg$\cdot$yr. We perform a detailed study of the expected background in the $0νββ$ signal region and find no evidence of $0νββ$ decays in the data. The level of observed background in the $0νββ$ signal region $[2.8-3.2]$ MeV is $0.44 \pm 0.13$ counts/yr/kg, and no events are observed in the interval $[3.2-10]$ MeV. We therefore derive a lower limit on the half-life of $0νββ$ decays in $^{100}$Mo of $T_{1/2}(0νββ)> 1.1 \times 10^{24}$ yr at the $90\%$ Confidence Level, under the hypothesis of light Majorana neutrino exchange. Depending on the model used for calculating nuclear matrix elements, the limit for the effective Majorana neutrino mass lies in the range $\langle m_ν \rangle < 0.33$--$0.62$ eV. We also report constraints on other lepton-number violating mechanisms for $0νββ$ decays.

hep-ex↗

A new variable for SRS plan quality evaluation based on normal tissue sparing: The Effect of Prescription Isodose Levels

Objectives: A new dosimetric variable, dose dropping speed (DDS), was proposed and used to evaluate normal tissue sparing among stereotactic radiosurgery (SRS) plans with different prescription isodose lines. Methods: Forty plans were generated for 8 intracranial SRS cases, prescribing to isodose levels (IDLs) ranging from 50% to 90% in 10% increments. Whilst maintaining similar coverage and conformity, plans at different IDLs were evaluated in terms of normal tissue sparing using the proposed DDS. The DDS was defined as the greater decay coefficient in a double exponential decay fit of the dose drop-off outside the PTV, which models the steep portion of the drop-off. Provided that the prescription dose covers the whole PTV, a greater DDS indicates better normal tissue sparing. Results: Among all plans, the DDS was found the lowest for the prescription at 90% IDL and the highest for the prescription at 60% or 70%. Beam profile slope change in penumbra and its field size dependence were explored and given as the physical basis of the findings. Conclusions: A variable was proposed for SRS plan quality evaluation. Using this measure, prescriptions at 60% and 70% IDLs were found to provide best normal tissue sparing. Advances in knowledge: A new variable was proposed based on which normal tissue sparing was quantitatively evaluated, comparing different prescription IDLs in SRS.

physics.med-ph↗

Search for Neutrinoless Double-Beta Decay of $^{100}$Mo with the NEMO-3 Detector

We report the results of a search for the neutrinoless double-$β$ decay (0$νββ$) of $^{100}$Mo, using the NEMO-3 detector to reconstruct the full topology of the final state events. With an exposure of 34.7 kg.y, no evidence for the 0$νββ$ signal has been found, yielding a limit for the light Majorana neutrino mass mechanism of $T_{1/2}(0νββ)>1.1 \times 10^{24}$ years (90% C.L.) once both statistical and systematic uncertainties are taken into account. Depending on the Nuclear Matrix Elements this corresponds to an upper limit on the Majorana effective neutrino mass of $< m_ν > < 0.3-0.9$ eV (90% C.L.). Constraints on other lepton number violating mechanisms of 0$νββ$ decays are also given. Searching for high-energy double electron events in all suitable sources of the detector, no event in the energy region [3.2-10] MeV is observed for an exposure of 47 kg.y.

hep-ex↗

The Electromagnetic Calorimeter for the T2K Near Detector ND280

The T2K experiment studies oscillations of an off-axis muon neutrino beam between the J-PARC accelerator complex and the Super-Kamiokande detector. Special emphasis is placed on measuring the mixing angle theta_13 by observing electron neutrino appearance via the sub-dominant muon neutrino to electron neutrino oscillation, and searching for CP violation in the lepton sector. The experiment includes a sophisticated, off-axis, near detector, the ND280, situated 280 m downstream of the neutrino production target in order to measure the properties of the neutrino beam and to understand better neutrino interactions at the energy scale below a few GeV. The data collected with the ND280 are used to study charged- and neutral-current neutrino interaction rates and kinematics prior to oscillation, in order to reduce uncertainties in the oscillation measurements by the far detector. A key element of the near detector is the ND280 electromagnetic calorimeter (ECal), consisting of active scintillator bars sandwiched between lead sheets and read outwith multi-pixel photon counters (MPPCs). The ECal is vital to the reconstruction of neutral particles, and the identification of charged particle species. The ECal surrounds the Pi-0 detector (P0D) and the tracking region of the ND280, and is enclosed in the former UA1/NOMAD dipole magnet. This paper describes the design, construction and assembly of the ECal, as well as the materials from which it is composed. The electronic and data acquisition (DAQ) systems are discussed, and performance of the ECal modules, as deduced from measurements with particle beams, cosmic rays, the calibration system, and T2K data, is described.

physics.ins-det↗

The case for a directional dark matter detector and the status of current experimental efforts

We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's status; and we close with a feasibility study for scaling up to a one ton directional detector, which would cost around $150M.

astro-ph.CO↗

Superfluid Density in a Highly Underdoped YBCO Superconductor

The superfluid density rho_s(T) = 1/lambda^2(T) has been measured at 2.64 GHz in highly underdoped YBCO, at 37 dopings with T_c between 3 K and 17 K. Within limits set by the transition width Delta T_c ~ 0.4 K, rho_s(T) shows no evidence of critical fluctuations as T goes to T_c, with a mean-field-like transition and no indication of vortex unbinding. Instead, we propose that rho_s displays the behaviour expected for a quantum phase transition in the (3 + 1)-dimensional XY universality class, with rho_s0 ~ (p - p_c), T_c ~ (p - p_c)^1/2 and rho_s(T) ~ (T_c - T)^1 as T goes to T_c.

cond-mat.supr-con↗

First results on double beta decay modes of Cd, Te and Zn isotopes with the COBRA experiment

Four 1cm^3 CdZnTe semiconductor detectors were operated in the Gran Sasso National Laboratory to explore the feasibility of such devices for double beta decay searches as proposed for the COBRA experiment. The research involved background studies accompanied by measurements of energy resolution performed at the surface. Energy resolutions sufficient to reduce the contribution of two-neutrino double beta decay events to a negligible level for a large scale experiment have already been achieved and further improvements are expected. Using activity measurements of contaminants in all construction materials a background model was developed with the help of Monte Carlo simulations and major background sources were identified. A total exposure of 4.34 kg.days of underground data has been accumulated allowing a search for neutrinoless double beta decay modes of seven isotopes found in CdZnTe. Half-life limits (90% C.L.) are presented for decays to ground and excited states. Four improved lower limits have been obtained, including zero neutrino double electron capture transitions of Zn64 and Te120 to the ground state, which are 1.19*10^{17} years and 2.68*10^{15} years respectively.

nucl-ex↗

First limits on WIMP nuclear recoil signals in ZEPLIN-II: a two phase xenon detector for dark matter detection

Results are presented from the first underground data run of ZEPLIN-II, a 31 kg two phase xenon detector developed to observe nuclear recoils from hypothetical weakly interacting massive dark matter particles. Discrimination between nuclear recoils and background electron recoils is afforded by recording both the scintillation and ionisation signals generated within the liquid xenon, with the ratio of these signals being different for the two classes of event. This ratio is calibrated for different incident species using an AmBe neutron source and Co-60 gamma-ray sources. From our first 31 live days of running ZEPLIN-II, the total exposure following the application of fiducial and stability cuts was 225 kgxdays. A background population of radon progeny events was observed in this run, arising from radon emission in the gas purification getters, due to radon daughter ion decays on the surfaces of the walls of the chamber. An acceptance window, defined by the neutron calibration data, of 50% nuclear recoil acceptance between 5 keVee and 20 keVee, had an observed count of 29 events, with a summed expectation of 28.6+/-4.3 gamma-ray and radon progeny induced background events. These figures provide a 90% c.l. upper limit to the number of nuclear recoils of 10.4 events in this acceptance window, which converts to a WIMP-nucleon spin-independent cross-section with a minimum of 6.6x10^-7 pb following the inclusion of an energy dependent, calibrated, efficiency. A second run is currently underway in which the radon progeny will be eliminated, thereby removing the background population, with a projected sensitivity of 2x10^-7 pb for similar exposures as the first run.

astro-ph↗

Radiation shielding for underground low-background experiments

The design task of creating an efficient radiation shield for the new COBRA double-beta decay experiment led to a comprehensive study of commercially available shielding materials. The aim was to find the most efficient combination of materials under the constraints of an extreme low-background experiment operating in a typical underground laboratory. All existing shield configurations for this type of experiment have been found to perform sub-optimally in comparison to the class of multilayered configurations proposed in this study. The method used here to create a specific shield configuration should yield a close to optimal result when applied to any experiment utilising a radiation shield. In particular, the survey of single material response to a given radiation source turns out to give a guideline for the construction of efficient multilayer shields.

nucl-ex↗

The ZEPLIN-III dark matter detector: instrument design, manufacture and commissioning

We present details of the technical design and manufacture of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use of liquid xenon. These include considerations of key performance parameters, such as the efficiency of scintillation light collection, restrictions placed on the use of materials to control the inherent radioactivity levels, attainment of high vacuum levels and chemical contamination control. The successful solution has involved a number of novel design and manufacturing features which will be of specific use to future generations of direct dark matter search experiments as they struggle with similar and progressively more demanding requirements.

astro-ph↗

The ZEPLIN-III dark matter detector: performance study using an end-to-end simulation tool

We present results from a GEANT4-based Monte Carlo tool for end-to-end simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase detector which measures both the scintillation light and the ionisation charge generated in liquid xenon by interacting particles and radiation. The software models the instrument response to radioactive backgrounds and calibration sources, including the generation, ray-tracing and detection of the primary and secondary scintillations in liquid and gaseous xenon, and subsequent processing by data acquisition electronics. A flexible user interface allows easy modification of detector parameters at run time. Realistic datasets can be produced to help with data analysis, an example of which is the position reconstruction algorithm developed from simulated data. We present a range of simulation results confirming the original design sensitivity of a few times $10^{-8}$ pb to the WIMP-nucleon cross-section.

astro-ph↗

Apparatus for high resolution microwave spectroscopy in strong magnetic fields

We have developed a low temperature, high-resolution microwave surface impedance probe that is able to operate in high static magnetic fields. Surface impedance is measured by cavity perturbation of dielectric resonators, with sufficient sensitivity to resolve the microwave absorption of sub-mm-sized superconducting samples. The resonators are constructed from high permittivity single-crystal rutile (TiO2) and have quality factors in excess of 10^6. Resonators with such high performance have traditionally required the use of superconducting materials, making them incompatible with large magnetic fields and subject to problems associated with aging and power-dependent response. Rutile resonators avoid these problems while retaining comparable sensitivity to surface impedance. Our cylindrical rutile resonators have a hollow bore and are excited in TE_01(n-d) modes, providing homogeneous microwave fields at the center of the resonator where the sample is positioned. Using a sapphire hot-finger technique, measurements can be made at sample temperatures in the range 1.1 K to 200 K, while the probe itself remains immersed in a liquid helium bath at 4.2 K. The novel apparatus described in this article is an extremely robust and versatile system for microwave spectroscopy, integrating several important features into a single system. These include: operation at high magnetic fields; multiple measurement frequencies between 2.64 GHz and 14.0 GHz in a single resonator; excellent frequency stability, with typical drifts < 1 Hz per hour; the ability to withdraw the sample from the resonator for background calibration; and a small pot of liquid helium separate from the external bath that provides a sample base temperature of 1.1 K.

cond-mat.supr-con↗

Simulations of neutron background in a time projection chamber relevant to dark matter searches

Presented here are results of simulations of neutron background performed for a time projection chamber acting as a particle dark matter detector in an underground laboratory. The investigated background includes neutrons from rock and detector components, generated via spontaneous fission and (alpha, n) reactions, as well as those due to cosmic-ray muons. Neutrons were propagated to the sensitive volume of the detector and the nuclear recoil spectra were calculated. Methods of neutron background suppression were also examined and limitations to the sensitivity of a gaseous dark matter detector are discussed. Results indicate that neutrons should not limit sensitivity to WIMP-nucleon interactions down to a level of (1 - 3) x 10^{-8} pb in a 10 kg detector.

hep-ex↗

Neutron background in large-scale xenon detectors for dark matter searches

Simulations of the neutron background for future large-scale particle dark matter detectors are presented. Neutrons were generated in rock and detector elements via spontaneous fission and (alpha,n) reactions, and by cosmic-ray muons. The simulation techniques and results are discussed in the context of the expected sensitivity of a generic liquid xenon dark matter detector. Methods of neutron background suppression are investigated. A sensitivity of $10^{-9}-10^{-10}$ pb to WIMP-nucleon interactions can be achieved by a tonne-scale detector.

hep-ex↗

The NAIAD experiment for WIMP searches at Boulby mine and recent results

The NAIAD experiment (NaI Advanced Detector) for WIMP dark matter searches at Boulby mine (UK) is described. The detector consists of an array of encapsulated and unencapsulated NaI(Tl) crystals with high light yield. Six crystals are collecting data at present. Data accumulated by four of them (10.6 kg x year exposure) have been used to set upper limits on the WIMP-nucleon spin-independent and WIMP-proton spin-dependent cross-sections. Pulse shape analysis has been applied to discriminate between nuclear recoils, as may be caused by WIMP interactions, and electron recoils due to gamma background. Various calibrations of crystals are presented.

hep-ex↗

CeCoIn5 - a quantum critical superfluid

We have made the first complete measurements of the London penetration depth $λ(T)$ of CeCoIn5, a quantum-critical metal where superconductivity arises from a non-Fermi-liquid normal state. Using a novel tunnel diode oscillator designed to avoid spurious contributions to $λ(T)$, we have established the existence of intrinsic and anomalous power-law behaviour at low temperature. A systematic analysis raises the possibility that the unusual observations are due to an extension of quantum criticality into the superconducting state.

cond-mat.supr-con↗