The T2K experiment studies oscillations of an off-axis muon neutrino beam between the J-PARC accelerator complex and the Super-Kamiokande detector. Special emphasis is placed on measuring the mixing angle theta_13 by observing electron neutrino appearance via the sub-dominant muon neutrino to electron neutrino oscillation, and searching for CP violation in the lepton sector. The experiment includes a sophisticated, off-axis, near detector, the ND280, situated 280 m downstream of the neutrino production target in order to measure the properties of the neutrino beam and to understand better neutrino interactions at the energy scale below a few GeV. The data collected with the ND280 are used to study charged- and neutral-current neutrino interaction rates and kinematics prior to oscillation, in order to reduce uncertainties in the oscillation measurements by the far detector. A key element of the near detector is the ND280 electromagnetic calorimeter (ECal), consisting of active scintillator bars sandwiched between lead sheets and read outwith multi-pixel photon counters (MPPCs). The ECal is vital to the reconstruction of neutral particles, and the identification of charged particle species. The ECal surrounds the Pi-0 detector (P0D) and the tracking region of the ND280, and is enclosed in the former UA1/NOMAD dipole magnet. This paper describes the design, construction and assembly of the ECal, as well as the materials from which it is composed. The electronic and data acquisition (DAQ) systems are discussed, and performance of the ECal modules, as deduced from measurements with particle beams, cosmic rays, the calibration system, and T2K data, is described.

Explore related subjects

Keep this discovery

BibTeXRIS

D. Allan, C. Andreopoulos, C. Angelsen, G. J. Barker, G. Barr, S. Bentham, I. Bertram, S. Boyd, K. Briggs, R. G. Calland, J. Carroll, S. L. Cartwright, A. Carver, C. Chavez, G. Christodoulou, J. Coleman, P. Cooke, G. Davies, C. Densham, F. Di Lodovico, J. Dobson, T. Duboyski, T. Durkin, D. L. Evans, A. Finch, M. Fitton, F. C. Gannaway, A. Grant, N. Grant, S. Grenwood, P. Guzowski, D. Hadley, M. Haigh, P. F. Harrison, A. Hatzikoutelis, T. D. J. Haycock, A. Hyndman, J. Ilic, S. Ives, A. C. Kaboth, V. Kasey, L. Kellet, M. Khaleeq, G. Kogan, L. L. Kormos, M. Lawe, T. B. Lawson, C. Lister, R. P. Litchfield, M. Lockwood, M. Malek, T. Maryon, P. Masliah, K. Mavrokoridis, N. McCauley, I. Mercer, C. Metelko, B. Morgan, J. Morris, A. Muir, M. Murdoch, T. Nicholls, M. Noy, H. M. O'Keeffe, R. A. Owen, D. Payne, G. F. Pearce, J. D. Perkin, E. Poplawska, R. Preece, W. Qian, P. Ratoff, T. Raufer, M. Raymond, M. Reeves, D. Richards, M. Rooney, R. Sacco, S. Sadler, P. Schaack, M. Scott, D. I. Scully, S. Short, M. Siyad, R. Smith, B. Still, P. Sutcliffe, I. J. Taylor, R. Terri, L. F. Thompson, A. Thorley, M. Thorpe, C. Timis, C. Touramanis, M. A. Uchida, Y. Uchida, A. Vacheret, J. F. VanSchalkwyk, O. Veledar, A. V. Waldron. 2013-08-15. The Electromagnetic Calorimeter for the T2K Near Detector ND280. https://doi.org/10.1088/1748-0221/8/10/p10019

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det