Searcharxiv⌕ Search

arXiv subjects

Brenda A. Cervantes-Vergara

Publications and source records attributed to Brenda A. Cervantes-Vergara.

18 recordsLinked to original sources

Characterization of Spurious Charge in SENSEI Skipper-CCDs

Skipper Charge-Coupled Devices (Skipper-CCDs) are a leading technology in the search for sub-GeV dark matter and coherent elastic neutrino-nucleus scattering. A key background for rare-event searches with these detectors arises from "spurious charge" -- single-electron events generated when charges are transferred through the active region to the serial register, and across the serial register to the readout stage. We present a characterization of spurious charge in both the active region and the serial register of SENSEI Skipper-CCDs, and show that, in a well-shielded low-background environment, the dominant contribution originates in the serial register during Skipper readout, when horizontal clocks are held at constant voltage between pixel transfers. Motivated by this finding, we develop a "tri-level" clocking scheme in which the held-low phase is raised to an intermediate voltage during readout to suppress trap-mediated charge generation. Using the SENSEI detector near the MINOS cavern, we measure a serial-register single-electron density of $(2.9 \pm 0.1) \times 10^{-5}$ electrons/pixel/image under standard SENSEI readout conditions, reduced to $(4.0 \pm 0.4) \times 10^{-6}$ electrons/pixel/image with tri-level clocking -- a factor of $\sim$7 improvement. This technique offers a promising path to lower backgrounds in current and future Skipper-CCD experiments.

physics.ins-det↗

Searches for CEνNS and Physics beyond the Standard Model using Skipper-CCDs at CONNIE

The Coherent Neutrino-Nucleus Interaction Experiment (CONNIE) aims to detect the coherent scattering (CE$ν$NS) of reactor antineutrinos off silicon nuclei using thick fully-depleted high-resistivity silicon CCDs. Two Skipper-CCD sensors with sub-electron readout noise capability were installed at the experiment next to the Angra-2 reactor in 2021, making CONNIE the first experiment to employ Skipper-CCDs for reactor neutrino detection. We report on the performance of the Skipper-CCDs, the new data processing and data quality selection techniques and the event selection for CE$ν$NS interactions, which enable CONNIE to reach a record low detection threshold of 15 eV. The data were collected over 300 days in 2021-2022 and correspond to exposures of 14.9 g-days with the reactor-on and 3.5 g-days with the reactor-off. The difference between the reactor-on and off event rates shows no excess and yields upper limits at 95% confidence level for the neutrino interaction rates comparable with previous CONNIE limits from standard CCDs and higher exposures. Searches for new neutrino interactions beyond the Standard Model were performed, yielding an improvement on the previous CONNIE limit on a simplified model with light vector mediators. A first dark matter (DM) search by diurnal modulation was performed by CONNIE and the results represent the best limits on the DM-electron scattering cross-section, obtained by a surface-level experiment. These promising results, obtained using a very small-mass sensor, illustrate the potential of Skipper-CCDs to probe rare neutrino interactions and motivate the plans to increase the detector mass in the near future.

hep-ex↗

X-ray characterization of fully-depleted p-channel Skipper-CCDs for the DarkNESS mission

The Dark matter Nanosatellite Equipped with Skipper Sensors (DarkNESS) mission is a 6U CubeSat designed to search for X-ray lines from decaying dark matter using Skipper-CCDs. Thick, fully-depleted p-channel Skipper-CCDs provide low readout noise and high quantum efficiency for 1-10 keV X-rays, but their X-ray performance has not yet been demonstrated in the space environment. DarkNESS will operate in low-Earth orbit, where trapped protons induce displacement damage in the sensor that increases charge-transfer inefficiency and degrades the X-ray energy resolution. This work measures the X-ray line response of Skipper-CCDs before and after proton irradiation and quantifies the associated degradation. A sensor was exposed to 217 MeV protons at a fluence of 8.4 x 10^10 protons cm^-2, corresponding to a displacement-damage dose more than an order of magnitude above the three-year expectation for representative mid-inclination and Sun-synchronous low-Earth orbits. A 55Fe source was used to compare the energy resolution of the beam-exposed quadrant to adjacent unexposed quadrants and a non-irradiated reference sensor. These measurements provide a quantitative assessment of radiation-induced spectral degradation in Skipper-CCDs and enable an estimate of the end-of-life X-ray energy resolution expected for DarkNESS operation in low-Earth orbit.

astro-ph.IM↗

SENSEI: A Search for Diurnal Modulation in sub-GeV Dark Matter Scattering

Dark matter particles with sufficiently large interactions with ordinary matter can scatter in the Earth's atmosphere and crust before reaching an underground detector. This Earth-shielding effect can induce a directional dependence in the dark matter flux, leading to a sidereal daily modulation in the signal rate. We perform a search for such a modulation using data from the SENSEI experiment, targeting MeV-scale dark matter. We achieve an order-of-magnitude improvement in sensitivity over previous direct-detection bounds for dark-matter masses below 1 MeV, assuming the Standard Halo Model with a Maxwell--Boltzmann velocity distribution, and constrain the amplitude of a general daily modulation signal to be below 6.8 electrons per gram per day.

hep-ex↗

A compact, low-power epithermal neutron counter for lunar water detection

The detection and characterization of lunar water are critical for enabling sustainable human and robotic exploration of the Moon. Orbital neutron spectrometers, such as instruments on Lunar Prospector and the Lunar Reconnaissance Orbiter, have revealed hydrogen-rich regions near the poles but are limited by coarse spatial resolution and low counting efficiency. We present a compact, lightweight, and low-power epithermal neutron detector based on boron-coated silicon imagers, designed to probe subsurface hydrogen at decimeter scales from mobile platforms such as lunar rovers. This instrument leverages the high neutron capture cross-section of $^{10}$B to convert epithermal neutrons into detectable $α$ and $^{7}$Li ions in a fully-depleted silicon imager, providing a unique event topology to identify neutrons while suppressing backgrounds. Monte Carlo simulations demonstrate that a 3 $μ$m boron layer achieves optimal neutron detection efficiency, further enhanced with polyethylene moderation to improve sensitivity to the 0.4 eV-500 keV epithermal energy range. For a 10 cm$^2$ active area, the detector achieves sensitivity to H$_2$O weight fractions as low as 0.01 wt % in a 15 minute measurement. This scalable, portable, low-mass design is well-suited for integration into upcoming Artemis and commercial lunar rovers, providing a transformative capability for in-situ resource prospecting and ground-truth validation of orbital measurements.

physics.ins-det↗

Investigation of Low-Energy Particle Remnants in High-Energy Collisions at the LHC with a Skipper-CCD detector

We deployed MOSKITA $\sim$33 m away from the CMS collision point, the first skipper-CCD detector probing low-energy particles produced in high-energy collisions at the Large Hadron Collider (LHC). In this work, we search for beam-related events using data collected in 2024 during beam-on and beam-off periods. The dataset corresponds to integrated luminosities of 113.3 fb$^{-1}$ and 1.54 nb$^{-1}$ for the proton-proton and Pb-Pb collision periods, respectively. We report observed event rates in a model-independent framework across two ionization regions: $\leq20e^-$ and $>20e^-$. For the low-energy region, we perform a likelihood analysis to test the null hypothesis of no beam-correlated signal. We found no significant correlation during proton-proton and Pb-Pb collisions. For the high-energy region, we present the energy spectra for both collision periods and compare event rates for images with and without luminosity. We observe a slight increase in the event rate following the Pb-Pb collisions, coinciding with a rise in the single-electron rate, which will be investigated in future work. Using the low-energy proton-proton results, we place 95% C.L. constraints on the mass-millicharge parameter space of millicharged particles. Overall, the results in this work demonstrate the viability of skipper-CCD technology to explore new physics at high-energy colliders and motivate future searches with more massive detectors.

hep-ex↗

DarkNESS: A skipper-CCD NanoSatellite for Dark Matter Searches

The Dark matter Nanosatellite Equipped with Skipper Sensors (DarkNESS) deploys a recently developed skipper-CCD architecture with sub-electron readout noise in low Earth orbit (LEO) to investigate potential signatures of dark matter (DM). The mission addresses two interaction channels: electron recoils from strongly interacting sub-GeV DM and X-rays produced through decaying DM. Orbital observations avoid attenuation that limits ground-based measurements, extending sensitivity reach for both channels. The mission proceeds toward launch following laboratory validation of the instrument. A launch opportunity has been secured through Firefly Aerospace's DREAM 2.0 program, awarded to the University of Illinois Urbana-Champaign (UIUC). This will constitute the first use of skipper-CCDs in space and evaluate their suitability for low-noise X-ray and single-photon detection in future space observatories.

astro-ph.IM↗

Characterization of proton-induced damage in thick, p-channel skipper-CCDs

In this work, we characterize the radiation-induced damage in two thick, p-channel skipper-CCDs irradiated unbiased and at room temperature with 217-MeV protons. We evaluate the overall performance of the sensors and demonstrate their single-electron/single-photon sensitivity after receiving a fluence on the order of 10$^{10}$~protons/cm$^2$. Using the pocket-pumping technique, we quantify and characterize the proton-induced defects from displacement damage. We report an overall trap density of 0.134~traps/pixel for a displacement damage dose of $2.3\times10^7$~MeV/g. Three main proton-induced trap species were identified, V$_2$, C$_i$O$_i$ and V$_n$O$_m$, and their characteristic trap energies and cross sections were extracted. We found that while divacancies are the most common proton-induced defects, C$_i$O$_i$ defects have a greater impact on charge integrity at typical operating temperatures because their emission-time constants are comparable or larger than typical readout times. To estimate ionization damage, we measure the characteristic output transistor curves. We found no threshold voltage shifts after irradiation. Our results highlight the potential of skipper-CCDs for applications requiring high-radiation tolerance and can be used to find the operating conditions in which effects of radiation-induced damage are mitigated.

physics.ins-det↗

Readout Optimization of Multi-Amplifier Sensing Charge-Coupled Devices for Single-Quantum Measurement

The non-destructive readout capability of the Skipper Charge Coupled Device (CCD) has been demonstrated to reduce the noise limitation of conventional silicon devices to levels that allow single-photon or single-electron counting. The noise reduction is achieved by taking multiple measurements of the charge in each pixel. These multiple measurements come at the cost of extra readout time, which has been a limitation for the broader adoption of this technology in particle physics, quantum imaging, and astronomy applications. This work presents recent results of a novel sensor architecture that uses multiple non-destructive floating-gate amplifiers in series to achieve sub-electron readout noise in a thick, fully-depleted silicon detector to overcome the readout time overhead of the Skipper-CCD. This sensor is called the Multiple-Amplifier Sensing Charge-Coupled Device (MAS-CCD) can perform multiple independent charge measurements with each amplifier, and the measurements from multiple amplifiers can be combined to further reduce the readout noise. We will show results obtained for sensors with 8 and 16 amplifiers per readout stage in new readout operations modes to optimize its readout speed. The noise reduction capability of the new techniques will be demonstrated in terms of its ability to reduce the noise by combining the information from the different amplifiers, and to resolve signals in the order of a single photon per pixel. The first readout operation explored here avoids the extra readout time needed in the MAS-CCD to read a line of the sensor associated with the extra extent of the serial register. The second technique explore the capability of the MAS-CCD device to perform a region of interest readout increasing the number of multiple samples per amplifier in a targeted region of the active area of the device.

astro-ph.IM↗

SENSEI: First Direct-Detection Results on sub-GeV Dark Matter from SENSEI at SNOLAB

We present the first results from a dark matter search using six Skipper-CCDs in the SENSEI detector operating at SNOLAB. We employ a bias-mitigation technique of hiding approximately 46% of our total data and aggressively mask images to remove backgrounds. Given a total exposure after masking of 100.72 gram-days from well-performing sensors, we observe 55 two-electron events, 4 three-electron events, and no events containing 4 to 10 electrons. The two-electron events are consistent with pileup from one-electron events. Among the 4 three-electron events, 2 appear in pixels that are likely impacted by detector defects, although not strongly enough to trigger our "hot-pixel" mask. We use these data to set world-leading constraints on sub-GeV dark matter interacting with electrons and nuclei.

astro-ph.CO↗

Search for reactor-produced millicharged particles with Skipper-CCDs at the CONNIE and Atucha-II experiments

Millicharged particles, proposed by various extensions of the standard model, can be created in pairs by high-energy photons within nuclear reactors and can interact electromagnetically with electrons in matter. Recently, the existence of a plasmon peak in the interaction cross-section with silicon in the eV range was highlighted as a promising approach to enhance low-energy sensitivities. The CONNIE and Atucha-II reactor neutrino experiments utilize Skipper-CCD sensors, which enable the detection of interactions in the eV range. We present world-leading limits on the charge of millicharged particles within a mass range spanning six orders of magnitude, derived through a comprehensive analysis and the combination of data from both experiments.

hep-ex↗

Sixteen Multiple-Amplifier Sensing Charge-Coupled Devices and Characterization Techniques Targeting the Next Generation of Astronomical Instruments

We present a candidate sensor for future spectroscopic applications, such as a Stage-5 Spectroscopic Survey Experiment or the Habitable Worlds Observatory. This type of charge-coupled device (CCD) sensor features multiple in-line amplifiers at its output stage allowing multiple measurements of the same charge packet, either in each amplifier or in the different amplifiers. Recently, the operation of an eight-amplifier sensor has been experimentally demonstrated, and we present the operation of a 16-amplifier sensor. This new sensor enables a noise level of ~1e-rms with a single sample per amplifier. In addition, it is shown that sub-electron noise can be achieved using multiple samples per amplifier. In addition to demonstrating the performance of the 16-amplifier sensor, we aim to create a framework for future analysis and performance optimization of this type of detectors. New models and techniques are presented to characterize specific parameters, which are absent in conventional CCDs and Skipper CCDs: charge transfer between amplifiers and independent and common noise in the amplifiers and their processing.

astro-ph.IM↗

SENSEI at SNOLAB: Single-Electron Event Rate and Implications for Dark Matter

We present results from data acquired by the SENSEI experiment at SNOLAB after a major upgrade in May 2023, which includes deploying 16 new sensors and replacing the copper trays that house the CCDs with a new light-tight design. We observe a single-electron event rate of $(1.39 \pm 0.11) \times 10^{-5}$ e$^-$/pix/day, corresponding to $(39.8 \pm 3.1)$ e$^-$/gram/day. This is an order-of-magnitude improvement compared to the previous lowest single-electron rate in a silicon detector and the lowest for any photon detector in the near-infrared-ultraviolet range. We use these data to obtain a 90% confidence level upper bound of $1.53 \times 10^{-5}$ e$^-$/pix/day and to set constraints on sub-GeV dark matter candidates that produce single-electron events. We hypothesize that the data taken at SNOLAB in the previous run, with an older tray design for the sensors, contained a larger rate of single-electron events due to light leaks. We test this hypothesis using data from the SENSEI detector located in the MINOS cavern at Fermilab.

astro-ph.CO↗

Skipper-CCD Sensors for the Oscura Experiment: Requirements and Preliminary Tests

Oscura is a proposed multi-kg skipper-CCD experiment designed for a dark matter (DM) direct detection search that will reach unprecedented sensitivity to sub-GeV DM-electron interactions with its 10 kg detector array. Oscura is planning to operate at SNOLAB with 2070 m overburden, and aims to reach a background goal of less than one event in each electron bin in the 2-10 electron ionization-signal region for the full 30 kg-year exposure, with a radiation background rate of 0.01 dru. In order to achieve this goal, Oscura must address each potential source of background events, including instrumental backgrounds. In this work, we discuss the main instrumental background sources and the strategy to control them, establishing a set of constraints on the sensors' performance parameters. We present results from the tests of the first fabricated Oscura prototype sensors, evaluate their performance in the context of the established constraints and estimate the Oscura instrumental background based on these results.

physics.ins-det↗

Searching for millicharged particles with 1 kg of Skipper-CCDs using the NuMI beam at Fermilab

Oscura is a planned light-dark matter search experiment using Skipper-CCDs with a total active mass of 10 kg. As part of the detector development, the collaboration plans to build the Oscura Integration Test (OIT), an engineering test with 10% of the total mass. Here we discuss the early science opportunities with the OIT to search for millicharged particles (mCPs) using the NuMI beam at Fermilab. mCPs would be produced at low energies through photon-mediated processes from decays of scalar, pseudoscalar, and vector mesons, or direct Drell-Yan productions. Estimates show that the OIT would be a world-leading probe for mCPs in the MeV mass range.

hep-ex↗

Fast Single-Quantum Measurement with a Multi-Amplifier Sensing Charge-Coupled Device

A novel readout architecture that uses multiple non-destructive floating-gate amplifiers to achieve sub-electron readout noise in a thick, fully-depleted silicon detector is presented. This Multi-Amplifier Sensing Charge-Coupled Device (MAS-CCD) can perform multiple independent charge measurements with each amplifier; measurements with multiple amplifiers can then be combined to further reduce the readout noise. The readout speed of this detector scales roughly linearly with the number of amplifiers without requiring segmentation of the active area. The performance of this detector is demonstrated, emphasizing the ability to resolve individual quanta and the ability to combine measurements across amplifiers to reduce readout noise. The unprecedented low noise and fast readout of the MAS-CCD make it a unique technology for astronomical observations, quantum imaging, and low-energy interacting particles.

astro-ph.IM↗

Search for coherent elastic neutrino-nucleus scattering at a nuclear reactor with CONNIE 2019 data

The Coherent Neutrino-Nucleus Interaction Experiment (CONNIE) is taking data at the Angra 2 nuclear reactor with the aim of detecting the coherent elastic scattering of reactor antineutrinos with silicon nuclei using charge-coupled devices (CCDs). In 2019 the experiment operated with a hardware binning applied to the readout stage, leading to lower levels of readout noise and improving the detection threshold down to 50 eV. The results of the analysis of 2019 data are reported here, corresponding to the detector array of 8 CCDs with a fiducial mass of 36.2 g and a total exposure of 2.2 kg-days. The difference between the reactor-on and reactor-off spectra shows no excess at low energies and yields upper limits at 95% confidence level for the neutrino interaction rates. In the lowest-energy range, 50-180 eV, the expected limit stands at 34 (39) times the standard model prediction, while the observed limit is 66 (75) times the standard model prediction with Sarkis (Chavarria) quenching factors.

hep-ex↗

Search for light mediators in the low-energy data of the CONNIE reactor neutrino experiment

The CONNIE experiment is located at a distance of 30 m from the core of a commercial nuclear reactor, and has collected a 3.7 kg-day exposure using a CCD detector array sensitive to an $\sim$1 keV threshold for the study of coherent neutrino-nucleus elastic scattering. Here we demonstrate the potential of this low-energy neutrino experiment as a probe for physics Beyond the Standard Model, by using the recently published results to constrain two simplified extensions of the Standard Model with light mediators. We compare the new limits with those obtained for the same models using neutrinos from the Spallation Neutron Source. Our new constraints represent the best limits for these simplified models among the experiments searching for CE$ν$NS for a light vector mediator with mass $M_{Z^{\prime}}<$ 10 MeV, and for a light scalar mediator with mass $M_ϕ<$ 30 MeV. These results constitute the first use of the CONNIE data as a probe for physics Beyond the Standard Model.

hep-ex↗