SearcharxivSearch

arXiv subjects

C. Cerna

Publications and source records attributed to C. Cerna.

At least 19 recordsLinked to original sources

Fabrication of thin planar radiopure foils with 82Se for the SuperNEMO Demonstrator

The SuperNEMO Demonstrator, designed to search for double beta decay using enriched 82Se, has been assembled in the Modane Underground Laboratory under the French Alps. Thin foils with radio - purified and enriched 82Se are installed centrally in the detector. A novel foil fabrication method has been developed, improving the radiopurity achieved in the previous generation experiment. It consists of wrapping standalone selenium pads in raw Mylar, combined with selenium purified by a new reverse-chromatography method. This paper describes the features of these foils, their fabrication process, the characterization results, and the integration of the foils into the SuperNEMO Demonstrator.

physics.ins-det

The Impact of Helium Exposure on the PMTs of the SuperNEMO Experiment

The performance of Hamamatsu 8" photomultiplier tubes (PMTs) of the type used in the SuperNEMO neutrinoless double-beta decay experiment (R5912-MOD), is investigated as a function of exposure to helium (He) gas. Two PMTs were monitored for over a year, one exposed to varying concentrations of He, and the other kept in standard atmospheric conditions as a control. Both PMTs were exposed to light signals generated by a Bi-207 radioactive source that provided consistent large input PMT signals similar to those that are typical of the SuperNEMO experiment. The energy resolution of PMT signals corresponding to 1 MeV energy scale determined from the Bi-207 decay spectrum, shows a negligible degradation with He exposure; however the rate of after-pulsing shows a clear increase with He exposure, which is modelled and compared to diffusion theory. A method for reconstructing the partial pressure of He within the PMT and a method for determining the He breakdown point, are introduced. The implications for long-term SuperNEMO operations are briefly discussed.

physics.ins-det

Calorimeter commissioning of the SuperNEMO Demonstrator

The SuperNEMO experiment is searching for neutrinoless double beta decay of \textsuperscript{82}Se, with the unique combination of a tracking detector and a segmented calorimeter. This feature allows to detect the two electrons emitted in the decay and measure their individual energy and angular distribution. The SuperNEMO calorimeter consists of 712 plastic scintillator blocks readout by large PMTs. After the construction of the demonstrator calorimeter underground, we have performed its first commissioning using $\gamma$-particles from calibration sources or from the ambient radioactive background. This article presents the quality assurance tests of the SuperNEMO demonstrator calorimeter and its first time and energy calibrations, with the associated methods.

physics.ins-det

R2D2 TPC: first Xenon results

Radial time projection chambers (TPC), already employed in the search for rare phenomena such as light Dark Matter candidate, could provide a new detection approach for the search of neutrinoless double beta decay ($\beta\beta0\nu$). The assessment of the performances of such a detector for $\beta\beta0\nu$ search is indeed the goal of the Rare Decays with Radial Detector (R2D2) R\&D. Promising results operating a spherical TPC with argon up to 1~bar have been published in 2021. Supplementary measurements were recently taken extending the gas pressure range up to 3~bar. In addition, a comparison between two detector geometries, namely spherical (SPC for spherical proportional counter) and cylindrical (CPC for cylindrical proportional counter), was performed. Using a relatively simple gas purification system the CPC detector was also operated with xenon at 1~bar: an energy resolution of 1.4\% full-width at half-maximum was achieved for drift distances up to 17~cm. Much lower resolution was observed with the SPC. These results are presented in this article.

physics.ins-det

Performance of a spherical high pressure gas TPC for neutrino magnetic moment measurement

The measurement of neutrino magnetic moment larger than $10^{-19}\mu_B$ would be a clear signature of physics beyond the standard model other than the existence of massive Dirac neutrinos. The use of a spherical proportional counter detector filled with gas at 40 bar located near a nuclear reactor would be a simple way to perform such a measurement exploiting the developments made on such a technology for the search of dark matter and neutrinoless double beta decay. Different targets can be used just by replacing the gas: xenon, CF$_4$ and argon were compared and the sensitivity in one year of data taking could reach the level of $4.3 \times 10^{-12} \mu_B$, $6.5 \times 10^{-12} \mu_B$, and $8.5 \times 10^{-12} \mu_B$, respectively.

hep-ex

Measurement of double-$\beta$ decay of $^{150}$Nd to the 0$^+_1$ excited state of $^{150}$Sm in NEMO-3

The NEMO-3 results for the double-$\beta$ decay of $^{150}$Nd to the 0$^+_1$ and 2$^+_1$ excited states of $^{150}$Sm are reported. The data recorded during 5.25 yr with 36.6 g of the isotope $^{150}$Nd are used in the analysis. For the first time, the signal of the $2\nu\beta\beta$ transition to the 0$^+_1$ excited state is detected with a statistical significance exceeding 5$\sigma$. The half-life is measured to be $T_{1/2}^{2\nu\beta\beta}(0^+_1) = \left[ 1.11 ^{+0.19}_{-0.14} \,\left(\mbox{stat}\right) ^{+0.17}_{-0.15}\, \left(\mbox{syst}\right) \right] \times10^{20}\,\mbox{yr}$. The limits are set on the $2\nu\beta\beta$ decay to the 2$^+_1$ level and on the $0\nu\beta\beta$ decay to the 0$^+_1$ and 2$^+_1$ levels of $^{150}$Sm.

nucl-ex

Simultaneous scintillation light and charge readout of a pure argon filled Spherical Proportional Counter

The possible use of a Spherical Proportional Counter for the search of neutrinoless double beta decay is investigated in the R2D2 R&D project. Dual charge and scintillation light readout may improve the detector performance. Tests were carried out with pure argon at 1.1 bar using a 6x6 mm2 silicon photomultiplier. Scintillation light was used for the first time to trigger in a spherical proportional counter. The measured drift time is in excellent agreement with the expectations from simulations. Furthermore the light signal emitted during the avalanche development exhibits features that could be exploited for event characterisation.

physics.ins-det

Measurement of the distribution of $^{207}$Bi depositions on calibration sources for SuperNEMO

The SuperNEMO experiment will search for neutrinoless double-beta decay ($0\nu\beta\beta$), and study the Standard-Model double-beta decay process ($2\nu\beta\beta$). The SuperNEMO technology can measure the energy of each of the electrons produced in a double-beta ($\beta\beta$) decay, and can reconstruct the topology of their individual tracks. The study of the double-beta decay spectrum requires very accurate energy calibration to be carried out periodically. The SuperNEMO Demonstrator Module will be calibrated using 42 calibration sources, each consisting of a droplet of $^{207}$Bi within a frame assembly. The quality of these sources, which depends upon the entire $^{207}$Bi droplet being contained within the frame, is key for correctly calibrating SuperNEMO's energy response. In this paper, we present a novel method for precisely measuring the exact geometry of the deposition of $^{207}$Bi droplets within the frames, using Timepix pixel detectors. We studied 49 different sources and selected 42 high-quality sources with the most central source positioning.

physics.ins-det

Search for Periodic Modulations of the Rate of Double-Beta Decay of $^{100}$Mo in the NEMO-3 Detector

Double-beta decays of $^{100}$Mo from the 6.0195-year exposure of a 6.914 kg high-purity sample were recorded by the NEMO-3 experiment that searched for neutrinoless double-beta decays. These ultra-rare transitions to $^{100}$Ru have a half-life of approximately $7\times10^{18}$ years, and have been used to conduct the first ever search for periodic variations of this decay mode. The Lomb-Scargle periodogram technique, and its error-weighted extension, were employed to look for periodic modulations of the half-life. Monte Carlo modeling was used to study the modulation sensitivity of the data over a broad range of amplitudes and frequencies. Data show no evidence of modulations with amplitude greater than 2.5% in the frequency range of $0.33225\,{\rm y^{-1}}$ to $365.25\,{\rm y^{-1}}$.

nucl-ex

R2D2 spherical TPC: first energy resolution results

Spherical time projection chambers (TPC), also known as spherical proportional counters, are employed in the search for rare phenomena, such as light Dark Matter candidates. The spherical TPC exhibits a number of essential features, making it a promising candidate for the search of neutrinoless double beta decay ($\beta\beta0\nu$). A tonne-scale spherical TPC experiment could cover a region of parameter space relevant for the inverted mass hierarchy with a few years of data taking. In this direction, the major R\&D goal of the R2D2 effort is the demonstration of the required energy resolution. First results from an argon-filled prototype detector are reported, demonstrating an energy resolution of 1.1\% FWHM for 5.3~MeV $\alpha$ tracks in the 0.2 to 1.1~bar pressure range. This is a major milestone in terms of energy resolution, paving the way for further studies with xenon gas, and the possible use of this technology for $\beta\beta0\nu$ searches.

physics.ins-det

Optimization of the JUNO liquid scintillator composition using a Daya Bay antineutrino detector

To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were increased in 12 steps from 0.5 g/L and <0.01 mg/L to 4 g/L and 13 mg/L, respectively. The numbers of total detected photoelectrons suggest that, with the optically purified solvent, the bis-MSB concentration does not need to be more than 4 mg/L. To bridge the one order of magnitude in the detector size difference between Daya Bay and JUNO, the Daya Bay data were used to tune the parameters of a newly developed optical model. Then, the model and tuned parameters were used in the JUNO simulation. This enabled to determine the optimal composition for the JUNO LS: purified solvent LAB with 2.5 g/L PPO, and 1 to 4 mg/L bis-MSB.

physics.ins-det

Search for the double-beta decay of 82Se to the excited states of 82Kr with NEMO-3

The double-beta decay of 82Se to the 0+1 excited state of 82Kr has been studied with the NEMO-3 detector using 0.93 kg of enriched 82Se measured for 4.75 y, corresponding to an exposure of 4.42 kg y. A dedicated analysis to reconstruct the gamma-rays has been performed to search for events in the 2e2g channel. No evidence of a 2nbb decay to the 0+1 state has been observed and a limit of T2n 1/2(82Se; 0+gs -> 0+1) > 1.3 1021 y at 90% CL has been set. Concerning the 0nbb decay to the 0+1 state, a limit for this decay has been obtained with T0n 1/2(82Se; 0+g s -> 0+1) > 2.3 1022 y at 90% CL, independently from the 2nbb decay process. These results are obtained for the first time with a tracko-calo detector, reconstructing every particle in the final state.

physics.ins-det

Detailed studies of $^{100}$Mo two-neutrino double beta decay in NEMO-3

The full data set of the NEMO-3 experiment has been used to measure the half-life of the two-neutrino double beta decay of $^{100}$Mo to the ground state of $^{100}$Ru, $T_{1/2} = \left[ 6.81 \pm 0.01\,\left(\mbox{stat}\right) ^{+0.38}_{-0.40}\,\left(\mbox{syst}\right) \right] \times10^{18}$ y. The two-electron energy sum, single electron energy spectra and distribution of the angle between the electrons are presented with an unprecedented statistics of $5\times10^5$ events and a signal-to-background ratio of ~80. Clear evidence for the Single State Dominance model is found for this nuclear transition. Limits on Majoron emitting neutrinoless double beta decay modes with spectral indices of n=2,3,7, as well as constraints on Lorentz invariance violation and on the bosonic neutrino contribution to the two-neutrino double beta decay mode are obtained.

nucl-ex

TRITIUM - A Real-Time Tritium Monitor System for Water Quality Surveillance

In this work the development results of the TRITIUM project is presented. The main objective of the project is the construction of a near real-time monitor for low activity tritium in water, aimed at in-situ surveillance and radiological protection of river water in the vicinity of nuclear power plants. The European Council Directive 2013/51/Euratom requires that the maximum level of tritium in water for human consumption to be lower than 100 Bq/L. Tritium levels in the cooling water of nuclear power plants in normal operation are much higher than the levels caused by the natural and cosmogenic components, and may easily surmount the limit required by the Directive. The current liquid-scintillation measuring systems in environmental radioactivity laboratories are sensitive to such low levels, but they are not suitable for real-time monitoring. Moreover, there is no currently available device with enough sensitivity and monitoring capabilities that could be used for surveillance of the cooling water of nuclear power plants. A detector system based on scintillation fibers read out by photomultiplier tubes (PMTs) or silicon photomultiplier (SiPM) arrays is under development for in-water tritium measurement. This detector will be installed in the vicinity of Almaraz nuclear power plant (Spain) in Spring 2019. An overview of the project development and the results of first prototypes are presented.

physics.ins-det

Final results on $^\textbf{82}$Se double beta decay to the ground state of $^\textbf{82}$Kr from the NEMO-3 experiment

Using data from the NEMO-3 experiment, we have measured the two-neutrino double beta decay ($2\nu\beta\beta$) half-life of $^{82}$Se as $T_{1/2}^{2\nu} = \left[ 9.39 \pm 0.17\,\left(\mbox{stat}\right) \pm 0.58\,\left(\mbox{syst}\right)\right] \times 10^{19}$ y under the single-state dominance hypothesis for this nuclear transition. The corresponding nuclear matrix element is $\left|M^{2\nu}\right| = 0.0498 \pm 0.0016$. In addition, a search for neutrinoless double beta decay ($0\nu\beta\beta$) using 0.93 kg of $^{82}$Se observed for a total of 5.25 y has been conducted and no evidence for a signal has been found. The resulting half-life limit of $T_{1/2}^{0\nu} > 2.5 \times 10^{23} \,\mbox{y} \,(90\%\,\mbox{C.L.})$ for the light neutrino exchange mechanism leads to a constraint on the effective Majorana neutrino mass of $\langle m_{\nu} \rangle < \left(1.2 - 3.0\right) \,\mbox{eV}$, where the range reflects $0\nu\beta\beta$ nuclear matrix element values from different calculations. Furthermore, constraints on lepton number violating parameters for other $0\nu\beta\beta$ mechanisms, such as right-handed currents, majoron emission and R-parity violating supersymmetry modes have been set.

hep-ex

Study of a spherical Xenon gas TPC for neutrinoless double beta detection

Several efforts are ongoing for the development of spherical gaseous time projection chamber detectors for the observation of rare phenomena such as weakly interacting massive particles or neutrino interactions. The proposed detector, thanks to its simplicity, low energy threshold and energy resolution, could be used to observe the $\beta\beta0\nu$ process i.e. the neutrinoless double beta decay. In this work, a specific setup is presented for the measurement of $\beta\beta0\nu$ on 50~kg of $^{136}$Xe. The different backgrounds are studied, demonstrating the possibility to reach a total background per year in the detector mass at the level of 2 events per year. The obtained results are competitive with the present generation of experiments and could represent the first step of a more ambitious roadmap including the $\beta\beta0\nu$ search with different gases with the same detector and therefore the same background sources. The constraints in terms of detector constructions and material purity are also addressed, showing that none of them represents a show stopper for the proposed experimental setup.

physics.ins-det

Calorimeter development for the SuperNEMO double beta decay experiment

SuperNEMO is a double-$\beta$ decay experiment, which will employ the successful tracker-calorimeter technique used in the recently completed NEMO-3 experiment. SuperNEMO will implement 100 kg of double-$\beta$ decay isotope, reaching a sensitivity to the neutrinoless double-$\beta$ decay ($0\nu\beta\beta$) half-life of the order of $10^{26}$ yr, corresponding to a Majorana neutrino mass of 50-100 meV. One of the main goals and challenges of the SuperNEMO detector development programme has been to reach a calorimeter energy resolution, $\Delta$E/E, around 3%/$sqrt(E)$(MeV) $\sigma$, or 7%/$sqrt(E)$(MeV) FWHM (full width at half maximum), using a calorimeter composed of large volume plastic scintillator blocks coupled to photomultiplier tubes. We describe the R\&D programme and the final design of the SuperNEMO calorimeter that has met this challenging goal.

physics.ins-det

Search for neutrinoless quadruple-$\beta$ decay of $^{150}$Nd with the NEMO-3 detector

We report the results of a first experimental search for lepton number violation by four units in the neutrinoless quadruple-$\beta$ decay of $^{150}$Nd using a total exposure of $0.19$ kg$\cdot$y recorded with the NEMO-3 detector at the Modane Underground Laboratory (LSM). We find no evidence of this decay and set lower limits on the half-life in the range $T_{1/2}>(1.1-3.2)\times10^{21}$ y at the $90\%$ CL, depending on the model used for the kinematic distributions of the emitted electrons.

hep-ex