SearcharxivSearch

arXiv subjects

C. Cerna

Publications and source records attributed to C. Cerna.

33 records · Page 2Linked to original sources

Search for neutrinoless quadruple-$β$ decay of $^{150}$Nd with the NEMO-3 detector

We report the results of a first experimental search for lepton number violation by four units in the neutrinoless quadruple-$β$ decay of $^{150}$Nd using a total exposure of $0.19$ kg$\cdot$y recorded with the NEMO-3 detector at the Modane Underground Laboratory (LSM). We find no evidence of this decay and set lower limits on the half-life in the range $T_{1/2}>(1.1-3.2)\times10^{21}$ y at the $90\%$ CL, depending on the model used for the kinematic distributions of the emitted electrons.

hep-ex

Measurement of the $2νββ$ Decay Half-Life and Search for the $0νββ$ Decay of $^{116}$Cd with the NEMO-3 Detector

The NEMO-3 experiment measured the half-life of the $2νββ$ decay and searched for the $0νββ$ decay of $^{116}$Cd. Using $410$ g of $^{116}$Cd installed in the detector with an exposure of $5.26$ y, ($4968\pm74$) events corresponding to the $2νββ$ decay of $^{116}$Cd to the ground state of $^{116}$Sn have been observed with a signal to background ratio of about $12$. The half-life of the $2νββ$ decay has been measured to be $ T_{1/2}^{2ν}=[2.74\pm0.04\mbox{(stat.)}\pm0.18\mbox{(syst.)}]\times10^{19}$ y. No events have been observed above the expected background while searching for $0νββ$ decay. The corresponding limit on the half-life is determined to be $T_{1/2}^{0ν} \ge 1.0 \times 10^{23}$ y at the $90$ % C.L. which corresponds to an upper limit on the effective Majorana neutrino mass of $\langle m_ν \rangle \le 1.4-2.5$ eV depending on the nuclear matrix elements considered. Limits on other mechanisms generating $0νββ$ decay such as the exchange of R-parity violating supersymmetric particles, right-handed currents and majoron emission are also obtained.

hep-ex

Measurement of the 2$νββ$ decay half-life of $^{150}$Nd and a search for 0$νββ$ decay processes with the full exposure from the NEMO-3 detector

We present results from a search for neutrinoless double-$β$ ($0νββ$) decay using 36.6 g of the isotope $^{150}$Nd with data corresponding to a live time of 5.25 y recorded with the NEMO-3 detector. We construct a complete background model for this isotope, including a measurement of the two-neutrino double-$β$ decay half-life of $T^{2ν}_{1/2}=$[9.34 $\pm$ 0.22 (stat.) $^{+0.62}_{-0.60}$ (syst.)]$\times 10^{18}$ y for the ground state transition, which represents the most precise result to date for this isotope. We perform a multivariate analysis to search for \zeronu decays in order to improve the sensitivity and, in the case of observation, disentangle the possible underlying decay mechanisms. As no evidence for \zeronu decay is observed, we derive lower limits on half-lives for several mechanisms involving physics beyond the Standard Model. The observed lower limit, assuming light Majorana neutrino exchange mediates the decay, is $T^{0ν}_{1/2} >$ 2.0 $\times 10^{22}$ y at the 90% C.L., corresponding to an upper limit on the effective neutrino mass of $\langle m_ν \rangle$ $<$ 1.6 - 5.3 eV..

hep-ex

Measurement of the double-beta decay half-life and search for the neutrinoless double-beta decay of $^{48}{\rm Ca}$ with the NEMO-3 detector

The NEMO-3 experiment at the Modane Underground Laboratory has investigated the double-$β$ decay of $^{48}{\rm Ca}$. Using $5.25$ yr of data recorded with a $6.99\,{\rm g}$ sample of $^{48}{\rm Ca}$, approximately $150$ double-$β$ decay candidate events have been selected with a signal-to-background ratio greater than $3$. The half-life for the two-neutrino double-$β$ decay of $^{48}{\rm Ca}$ has been measured to be $T^{2ν}_{1/2}\,=\,[6.4\, ^{+0.7}_{-0.6}{\rm (stat.)} \, ^{+1.2}_{-0.9}{\rm (syst.)}] \times 10^{19}\,{\rm yr}$. A search for neutrinoless double-$β$ decay of $^{48}{\rm Ca}$ yields a null result and a corresponding lower limit on the half-life is found to be $T^{0ν}_{1/2} > 2.0 \times 10^{22}\,{\rm yr}$ at $90\%$ confidence level, translating into an upper limit on the effective Majorana neutrino mass of $< m_{ββ} > < 6.0 - 26$ ${\rm eV}$, with the range reflecting different nuclear matrix element calculations. Limits are also set on models involving Majoron emission and right-handed currents.

hep-ex

Result of the search for neutrinoless double-$β$ decay in $^{100}$Mo with the NEMO-3 experiment

The NEMO-3 detector, which had been operating in the Modane Underground Laboratory from 2003 to 2010, was designed to search for neutrinoless double $β$ ($0νββ$) decay. We report final results of a search for $0νββ$ decays with $6.914$ kg of $^{100}$Mo using the entire NEMO-3 data set with a detector live time of $4.96$ yr, which corresponds to an exposure of 34.3 kg$\cdot$yr. We perform a detailed study of the expected background in the $0νββ$ signal region and find no evidence of $0νββ$ decays in the data. The level of observed background in the $0νββ$ signal region $[2.8-3.2]$ MeV is $0.44 \pm 0.13$ counts/yr/kg, and no events are observed in the interval $[3.2-10]$ MeV. We therefore derive a lower limit on the half-life of $0νββ$ decays in $^{100}$Mo of $T_{1/2}(0νββ)> 1.1 \times 10^{24}$ yr at the $90\%$ Confidence Level, under the hypothesis of light Majorana neutrino exchange. Depending on the model used for calculating nuclear matrix elements, the limit for the effective Majorana neutrino mass lies in the range $\langle m_ν \rangle < 0.33$--$0.62$ eV. We also report constraints on other lepton-number violating mechanisms for $0νββ$ decays.

hep-ex

Reference material for natural radionuclides in glass designed for underground experiments

A reference material designed for the determination of natural radionuclides in solid samples (glass pellets) is described and the results of certification are presented. The material has been certified for 7 natural radionuclides (40K, 226Ra, 228Ra, 228Th, 232Th, 235U and 238U). An information value is given for 210Pb. Radon (222Rn) emanation experiments showed results comparable within participating laboratories, however, the number of data and precision was too low to carry out a certification process. The reference material may be used for quality management of analytical laboratories engaged in the high-sensitive analysis of radionuclides in the construction materials of detectors placed in ultra low background underground laboratories.

physics.ins-det

Search for Neutrinoless Double-Beta Decay of $^{100}$Mo with the NEMO-3 Detector

We report the results of a search for the neutrinoless double-$β$ decay (0$νββ$) of $^{100}$Mo, using the NEMO-3 detector to reconstruct the full topology of the final state events. With an exposure of 34.7 kg.y, no evidence for the 0$νββ$ signal has been found, yielding a limit for the light Majorana neutrino mass mechanism of $T_{1/2}(0νββ)>1.1 \times 10^{24}$ years (90% C.L.) once both statistical and systematic uncertainties are taken into account. Depending on the Nuclear Matrix Elements this corresponds to an upper limit on the Majorana effective neutrino mass of $< m_ν > < 0.3-0.9$ eV (90% C.L.). Constraints on other lepton number violating mechanisms of 0$νββ$ decays are also given. Searching for high-energy double electron events in all suitable sources of the detector, no event in the energy region [3.2-10] MeV is observed for an exposure of 47 kg.y.

hep-ex

Euclid Definition Study Report

Euclid is a space-based survey mission from the European Space Agency designed to understand the origin of the Universe's accelerating expansion. It will use cosmological probes to investigate the nature of dark energy, dark matter and gravity by tracking their observational signatures on the geometry of the universe and on the cosmic history of structure formation. The mission is optimised for two independent primary cosmological probes: Weak gravitational Lensing (WL) and Baryonic Acoustic Oscillations (BAO). The Euclid payload consists of a 1.2 m Korsch telescope designed to provide a large field of view. It carries two instruments with a common field-of-view of ~0.54 deg2: the visual imager (VIS) and the near infrared instrument (NISP) which contains a slitless spectrometer and a three bands photometer. The Euclid wide survey will cover 15,000 deg2 of the extragalactic sky and is complemented by two 20 deg2 deep fields. For WL, Euclid measures the shapes of 30-40 resolved galaxies per arcmin2 in one broad visible R+I+Z band (550-920 nm). The photometric redshifts for these galaxies reach a precision of dz/(1+z) < 0.05. They are derived from three additional Euclid NIR bands (Y, J, H in the range 0.92-2.0 micron), complemented by ground based photometry in visible bands derived from public data or through engaged collaborations. The BAO are determined from a spectroscopic survey with a redshift accuracy dz/(1+z) =0.001. The slitless spectrometer, with spectral resolution ~250, predominantly detects Ha emission line galaxies. Euclid is a Medium Class mission of the ESA Cosmic Vision 2015-2025 programme, with a foreseen launch date in 2019. This report (also known as the Euclid Red Book) describes the outcome of the Phase A study.

astro-ph.CO

Frequency Analysis of the noise in the Fowler(n) sampling of a H2RG(2Kx2K) Near-IR Detector

The readout noise of a H2RG HgCdTe NIR detector from Teledyne is measured at a temperature T=110K. It is shown that a Fowler mode with n = 240 allows to reach a noise of 2.63e (single read). A description of the power spectrum in terms of 3 parameters reproduces the variation of the noise as a function the number of Fowler samples, as well as its dependence on the periodicity of the sampling. The variance of the noise decreases with frequency with an effective power of 0.62 in our measurement domain. The behaviour of the detector under different experimental conditions can then be predicted.

astro-ph.IM

Calibration and Interpixel Capacitance of a H2RG(2Kx2K) Near-IR Detector

A temporal analysis of the noise is performed, and non linearities are taken into account. We then extend the correlation method to groups of several pixels to derive the interpixel capacitance of a detector, found to be x = -0.0263 +/- 0.0020 (stat) +/- 0.0040 (syst). All measurements are consistent to a sub-percent accuracy.

astro-ph.IM

Image Slicer Performances from a Demonstrator for the SNAP/JDEM Mission - Part I: Wavelength Accuracy

A well-adapted visible and infrared spectrograph has been developed for the SNAP (SuperNova/Acceleration Probe) experiment proposed for JDEM. The instrument should have a high sensitivity to see faint supernovae but also a good redshift determination better than 0.003(1+z) and a precise spectrophotometry (2%). An instrument based on an integral field method with the powerful concept of imager slicing has been designed. A large prototyping effort has been performed in France which validates the concept. In particular a demonstrator reproducing the full optical configuration has been built and tested to prove the optical performances both in the visible and in the near infrared range. This paper is the first of two papers. The present paper focus on the wavelength measurement while the second one will present the spectrophotometric performances. We adress here the spectral accuracy expected both in the visible and in the near infrared range in such configuration and we demonstrate, in particular, that the image slicer enhances the instrumental performances in the spectral measurement precision by removing the slit effect. This work is supported in France by CNRS/INSU/IN2P3 and by the French spatial agency (CNES) and in US by the University of California.

astro-ph

Low energy tracking and particles identification in the MUNU Time Projection Chamber at 1 bar. Possible application in low energy solar neutrino spectroscopy

In this paper we present the results from the measurements made with the MUNU TPC at 1bar pressure of CF4 in the energy region below 1 MeV. Electron events down to 80 keV are successfully measured. The electron energy and direction are reconstructed for every contained single electron above 200 keV. As test the 137Cs photopeak is reconstructed by measuring both the energy and direction of the Compton electrons in the TPC.

hep-ex

Final results on the neutrino magnetic moment from the MUNU experiment

The MUNU detector was designed to study neutrino-electron elastic scattering at low energy. The central component is a Time Projection Chamber filled with CF4 gas, surrounded by an anti-Compton detector. The experiment was carried out at the Bugey (France) nuclear reactor. In this paper we present the final analysis of the data recorded at 3 bar and 1 bar pressure. Both the energy and the scattering angle of the recoil electron are measured. From the 3 bar data a new upper limit on the neutrino magnetic moment was derived. At 1 bar electron tracks down to 150 keV were reconstructed, demonstrating the potentiality of the experimental technique for future applications in low energy neutrino physics.

hep-ex

Limits on the neutrino magnetic moment from the MUNU experiment

The MUNU experiment was carried out at the Bugey nuclear power reactor. The aim was the study of electron antineutrino-electron elastic scattering at low energy. The recoil electrons were recorded in a gas time projection chamber, immersed in a tank filled with liquid scintillator serving as veto detector, suppressing in particular Compton electrons. The measured electron recoil spectrum is presented. Upper limits on the neutrino magnetic moment were derived and are discussed.

hep-ex

Sub MeV Particles Detection and Identification in the MUNU detector ((1)ISN, IN2P3/CNRS-UJF, Grenoble, France, (2)Institut de Physique, Neuchâtel, Switzerland, (3) INFN, Padova Italy, (4) Physik-Institut, Zürich, Switzerland)

We report on the performance of a 1 m$^{3}$ TPC filled with CF$_{4}$ at 3 bar, immersed in liquid scintillator and viewed by photomultipliers. Particle detection, event identification and localization achieved by measuring both the current signal and the scintillation light are presented. Particular features of $α$ particle detection are also discussed. Finally, the ${54}$Mn photopeak, reconstructed from the Compton scattering and recoil angle is shown.