Searcharxiv⌕ Search

arXiv subjects

C. Curceanu

Publications and source records attributed to C. Curceanu.

At least 73 records · Page 4Linked to original sources

VOXES: a high precision X-ray spectrometer for diffused sources with HAPG crystals in the 2-20 keV range

Bragg spectroscopy is one of the best established experimental methods for high energy resolution X-ray measurements and has been widely used in several fields, going from fundamental physics to quantum mechanics tests, synchrotron radiation and X-FEL applications, astronomy, medicine and industry. However, this technique is limited to the measurement of photons produced from well collimated or point-like sources and becomes quite inefficient for photons coming from extended and diffused sources like those,for example, emitted in the exotic atoms radiative transitions. The VOXES project's goal is to realise a prototype of a high resolution and high precision X-ray spectrometer, using Highly Annealed Pyrolitic Graphite (HAPG) crystals in the Von Hamos configuration, working also for extended sources. The aim is to deliver a cost effective system having an energy resolution at the level of eV for X rays energies from about 2 keV up to tens of keV, able to perform sub-eV precision measurements with non point-like sources. In this paper, the working principle of VOXES, together with first results, are presented.

physics.ins-det↗

Experimental search for the violation of Pauli Exclusion Principle

The VIolation of Pauli exclusion principle -2 experiment, or VIP-2 experiment, at the Laboratori Nazionali del Gran Sasso searches for x-rays from copper atomic transition that are prohibited by the Pauli Exclusion Principle. Candidate direct violation events come from the transition of a $2p$ electron to the ground state that is already occupied by two electrons. From the first data taking campaign in 2016 of VIP-2 experiment, we determined a best upper limit of 3.4 $\times$ 10$^{-29}$ for the probability that such a violation exists. Significant improvement in the control of the experimental systematics was also achieved, although not explicitly reflected in the improved upper limit. By introducing a simultaneous spectral fit of the signal and background data in the analysis, we succeeded in taking into account systematic errors that could not be evaluated previously in this type of measurements.

physics.atom-ph↗

Feasibility study of the time reversal symmetry tests in decays of metastable positronium atoms with the J-PET detector

This article reports on the feasibility of testing of the symmetry under reversal in time in a purely leptonic system constituted by positronium atoms using the J-PET detector. The present state of T symmetry tests is discussed with an emphasis on the scarcely explored sector of leptonic systems. Two possible strategies of searching for manifestations of T violation in non-vanishing angular correlations of final state observables in the decays of metastable triplet states of positronium available with J-PET are proposed and discussed. Results of a pilot measurement with J-PET and assessment of its performance in reconstruction of three-photon decays are shown along with an analysis of its impact on the sensitivity of the detector for the determination of T -violation sensitive observables.

physics.ins-det↗

The kaonic atoms research program at DAΦNE: from SIDDHARTA to SIDDHARTA-2

The interaction of antikaons with nucleons and nuclei in the low-energy regime represents an active research field in hadron physics with still many important open questions. The investigation of light kaonic atoms, in which one electron is replaced by a negatively charged kaon, is a unique tool to provide precise information on this interaction; the energy shift and the broadening of the low-lying states of such atoms, induced by the kaon-nucleus hadronic interaction, can be determined with high precision from the atomic X-ray spectroscopy, and this experimental method provides unique information to understand the low energy kaon-nucleus interaction at the production threshold. The lightest atomic systems, like the kaonic hydrogen and the kaonic deuterium deliver, in a model-independent way, the isospin-dependent kaon-nucleon scattering lengths. The most precise kaonic hydrogen measurement to-date, together with an exploratory measurement of kaonic deuterium, were carried out in 2009 by the SIDDHARTA collaboration at the DAΦNE electron-positron collider of LNF-INFN, combining the excellent quality kaon beam delivered by the collider with new experimental techniques, as fast and very precise X-ray detectors, like the Silicon Drift Detectors. The SIDDHARTA results triggered new theoretical work, which achieved major progress in the understanding of the low-energy strong interaction with strangeness reflected by the antikaon-nucleon scattering lengths calculated with the antikaon-proton amplitudes constrained by the SIDDHARTA data. The most important open question is the experimental determination of the hadronic energy shift and width of kaonic deuterium; presently, a major upgrade of the setup, SIDDHARTA-2, is being realized to reach this goal. In this paper, the results obtained in 2009 and the proposed SIDDHARTA-2 upgrades are presented.

nucl-ex↗

Towards 2+1 photon tomography: Energy-based selection of two 511 keV photons and a prompt photon with the J-PET scanner

The possibility to separate signals caused by 511 keV photons created in annihilation of electron-positron pairs and the so-called prompt photons from nuclei de- excitation is investigated. It could potentially be used to improve the quality of reconstructed images in the J-PET scanner in 2+1 photon tomography. Firstly, a research is conducted for several radioisotopes that decay via \b{eta}+ decay followed by de-excitation of an excited nucleus. Efficiency, purity and false positive rate are calculated for each isotope as a function of energy deposited threshold, with a hypothesis that signals caused by 511 keV photons deposit smaller values of energy than 1 z 13the selected threshold, while prompt photons deposit larger energy than the threshold. Analysis of the results accompanied with physical properties of radioisotopes suggests using 44 Sc, which is the most promising candidate for medical applications. With the use of GATE and J-POS simulation software, in-phantom scattering was introduced and the best energy deposited threshold value was estimated to be approximately 375 keV. It corresponds to almost 100% efficiency for 511 keV signals, 75% purity for 511 keV photons, and approximately 70% efficiency and purity for prompt photons.

physics.med-ph↗

Test of the Pauli Exclusion Principle in the VIP-2 underground experiment

The validity of the Pauli Exclusion Principle, a building block of Quantum Mechanics, is tested for electrons. The VIP (VIolation of Pauli exclusion principle) and its follow-up VIP-2 experiments at the Laboratori Nazionali del Gran Sasso search for x-rays from copper atomic transition that are prohibited by the Pauli Exclusion Principle. The candidate events, if they exist, originate from the transition of a $2p$ orbit electron to the ground state which is already occupied by two electrons. The present limit on the probability for Pauli Exclusion Principle violation for electrons set by the VIP experiment is 4.7 $\times$ 10 $^{-29}$. We report a first result from the VIP-2 experiment improving on the VIP limit, that solidifies the final goal to achieve a two order of magnitude gain in the long run.

quant-ph↗

Human Tissues Investigation Using PALS Technique

Samples of uterine leiomyomatis and normal tissues taken from patients after surgery were investigated using the Positron Annihilation Lifetime Spectroscopy (PALS). Significant differences in all PALS parameters between normal and diseased tissues were observed. For all studied patients, it was found that the values of the free annihilation and ortho-positronium lifetime are larger for the tumorous tissues than for the healthy ones. For most of the patients, the intensity of the free annihilation and ortho-positronium annihilation was smaller for the tumorous than for the healthy tissues. For the first time, in this kind of studies, the $3γ$ fraction of positron annihilation was determined to describe changes in the tissue porosity during morphologic alteration.

physics.med-ph↗

Commissioning of the J-PET detector for studies of decays of positronium atoms

The Jagiellonian Positron Emission Tomograph (J-PET) is a detector for medical imaging of the whole human body as well as for physics studies involving detection of electron-positron annihilation into photons. J-PET has high angular and time resolution and allows for measurement of spin of the positronium and the momenta and polarization vectors of annihilation quanta. In this article, we present the potential of the J-PET system for background rejection in the decays of positronium atoms.

physics.ins-det↗

VIP2 at Gran Sasso - Test of the validity of the spin statistics theorem for electrons with X-ray spectroscopy

In the VIP2 (VIolation of the Pauli Exlusion Principle) experiment at the Gran Sasso underground laboratory (LNGS) we are searching for possible violations of standard quantum mechanics predictions. With high precision we investigate the Pauli Exclusion Principle and the collapse of the wave function (collapse models). We will present our experimental method of searching for possible small violations of the Pauli Exclusion Principle for electrons, via the search for "anomalous" X-ray transitions in copper atoms, produced by "new" electrons (brought inside a copper bar by circulating current) which could have the probability to undergo Pauli-forbidden transition to the ground state (1 s level) already occupied by two electrons. We will describe the concept of the VIP2 experiment taking data at LNGS presently. The goal of VIP2 is to test the PEP for electrons with unprecedented accuracy, down to a limit in the probability that PEP is violated at the level of 10$^{-31}$. We will show preliminary experimental results obtained at LNGS and discuss implications of a possible violation.

physics.ins-det↗

J-PET: a new technology for the whole-body PET imaging

The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET built from plastic scintillators. J-PET prototype consists of 192 detection modules arranged axially in three layers forming a cylindrical diagnostic chamber with the inner diameter of 85 cm and the axial field-of-view of 50 cm. An axial arrangement of long strips of plastic scintillators, their small light attenuation, superior timing properties, and relative ease of the increase of the axial field-of-view opens promising perspectives for the cost effective construction of the whole-body PET scanner, as well as construction of MR and CT compatible PET inserts. Present status of the development of the J-PET tomograph will be presented and discussed.

physics.ins-det↗

Introduction of total variation regularization into filtered backprojection algorithm

In this paper we extend the state-of-the-art filtered backprojection (FBP) method with application of the concept of Total Variation regularization. We compare the performance of the new algorithm with the most common form of regularizing in the FBP image reconstruction via apodizing functions. The methods are validated in terms of cross-correlation coefficient between reconstructed and real image of radioactive tracer distribution using standard Derenzo-type phantom. We demonstrate that the proposed approach results in higher cross-correlation values with respect to the standard FBP method.

physics.med-ph↗

Three-dimensional image reconstruction in J-PET using Filtered Back Projection method

We present a method and preliminary results of the image reconstruction in the Jagiellonian PET tomograph. Using GATE (Geant4 Application for Tomographic Emission), interactions of the 511 keV photons with a cylindrical detector were generated. Pairs of such photons, flying back-to-back, originate from e+e- annihilations inside a 1-mm spherical source. Spatial and temporal coordinates of hits were smeared using experimental resolutions of the detector. We incorporated the algorithm of the 3D Filtered Back Projection, implemented in the STIR and TomoPy software packages, which differ in approximation methods. Consistent results for the Point Spread Functions of ~5/7,mm and ~9/20, mm were obtained, using STIR, for transverse and longitudinal directions, respectively, with no time of flight information included.

physics.ins-det↗

Time calibration of the J-PET detector

The Jagiellonian Positron Emission Tomograph (J-PET) project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the first prototype of PET scanner for medical diagnostic which allows for the simultaneous 3D imaging of the whole human body using organic scintillators. The J-PET prototype consists of 192 scintillator strips forming three cylindrical layers which are optimized for the detection of photons from the electron-positron annihilation with high time- and high angular-resolutions. In this article we present time calibration and synchronization of the whole J-PET detection system by irradiating each single detection module with a 22Na source and a small detector providing common reference time for synchronization of all the modules.

physics.ins-det↗

CSL Collapse Model Mapped with the Spontaneous Radiation

In this paper, new upper limits on the parameters of the Continuous Spontaneous Localization (CSL) collapse model are extracted. To this end, the X-ray emission data collected by the IGEX collaboration are analyzed and compared with the spectrum of the spontaneous photon emission process predicted by collapse models. This study allows the obtainment of the most stringent limits within a relevant range of the CSL model parameters, with respect to any other method. The collapse rate $λ$ and the correlation length $r_C$ are mapped, thus allowing the exclusion of a broad range of the parameter space.

quant-ph↗

VOXES, a new high resolution X-ray spectrometer for low yield measurements with diffused sources

The VOXES project's goal is to realize the first prototype of a high resolution and high precision X-ray spectrometer for diffused sources, using Highly Annealed Pyrolitic Graphite (HAPG) crystals combined with precision position detectors. The aim is to deliver a cost effective and easy to handle system having an energy resolution at the level of few eV for X-ray energies from about 2 keV up to tens of keV. There are many applications of the proposed spectrometer, going from fundamental physics (precision measurements of exotic atoms at DA$Φ$NE collider and J-PARC, precision measurement of the $K^-$ mass solving the existing puzzle, quantum mechanics tests) to synchrotron radiation and applications (X-FEL), astronomy, medicine and industry. Here, the basic concept of such a spectrometer and the first results from a measurement of the characteristic Cu $K_{α1}$ and $K_{α2}$ X-ray lines are presented.

physics.ins-det↗

Calculation of time resolution of the J-PET tomograph using the Kernel Density Estimation

In this paper we estimate the time resolution of the J-PET scanner built from plastic scintillators. We incorporate the method of signal processing using the Tikhonov regularization framework and the Kernel Density Estimation method. We obtain simple, closed-form analytical formulas for time resolutions. The proposed method is validated using signals registered by means of the single detection unit of the J-PET tomograph built out from 30 cm long plastic scintillator strip. It is shown that the experimental and theoretical results, obtained for the J-PET scanner equipped with vacuum tube photomultipliers, are consistent.

physics.ins-det↗

Antikaon Interactions with Nucleons and Nuclei - AMADEUS At Da$Φ$ne

The aim of AMADEUS is to provide unprecedented experimental information on K$^-$ absorption in light nuclear targets, to face major open problems in hadron nuclear physics in the strangeness sector, namely the nature of the $Λ$(1405), strongly related to the possible existence of kaonic nuclear clusters, kaons and hyperon scattering cross sections on nucleons and nuclei. These issues are fundamental for a better understanding of the non-perturbative QCD in the strangeness sector. AMADEUS step 0 deals with the analysis of the 2004-2005 KLOE collected data. The interactions of the negative kaons produced by the DA$Φ$NE collider (a unique source of monochromatic low-momentum kaons) with the materials of the KLOE detector, used as active targets, provide samples of K$^-$ absorptions on H, ${}^4$He, ${}^{9}$Be and ${}^{12}$C, both at-rest and in-flight. A second step deals with the data from the implementation in the central region of the KLOE detector of a pure graphite target, providing a high statistic sample of K$^- \, {}^{12}$C nuclear captures at rest. For the future a new setup, with various dedicated gaseous and solid targets, is under preparation.

nucl-ex↗