Underground tests of quantum mechanics. Whispers in the cosmic silence?

By performing X-rays measurements in the "cosmic silence" of the underground laboratory of Gran Sasso, LNGS-INFN, we test a basic principle of quantum mechanics: the Pauli Exclusion Principle (PEP), for electrons. We present the achieved results of the VIP experiment and the ongoing VIP2 measurement aiming to gain two orders of magnitude improvement in testing PEP. We also use a similar experimental technique to search for radiation (X and gamma) predicted by continuous spontaneous localization models, which aim to solve the "measurement problem".

quant-ph↗

VIP-2 at LNGS: An experiment on the validity of the Pauli Exclusion Principle for electrons

We are experimentally investigating possible violations of standard quantum mechanics predictions in the Gran Sasso underground laboratory in Italy. We test with high precision the Pauli Exclusion Principle and the collapse of the wave function (collapse models). We present our method of searching for possible small violations of the Pauli Exclusion Principle (PEP) for electrons, through the search for anomalous X-ray transitions in copper atoms. These transitions are produced by new electrons (brought inside the copper bar by circulating current) which can have the possibility to undergo Pauli-forbidden transition to the 1s level already occupied by two electrons. We describe the VIP2 (VIolation of the Pauli Exclusion Principle) experimental data taking at the Gran Sasso underground laboratories. The goal of VIP2 is to test the PEP for electrons in agreement with the Messiah-Greenberg superselection rule with unprecedented accuracy, down to a limit in the probability that PEP is violated at the level of 10E-31. We show preliminary experimental results and discuss implications of a possible violation.

quant-ph↗

A feasibility study of ortho-positronium decays measurement with the J-PET scanner based on plastic scintillators

We present a study of the application of the Jagiellonian Positron Emission Tomograph (J-PET) for the registration of gamma quanta from decays of ortho-positronium (o-Ps). The J-PET is the first positron emission tomography scanner based on organic scintillators in contrast to all current PET scanners based on inorganic crystals. Monte Carlo simulations show that the J-PET as an axially symmetric and high acceptance scanner can be used as a multi-purpose detector well suited to pursue research including e.g. tests of discrete symmetries in decays of ortho-positronium in addition to the medical imaging. The gamma quanta originating from o-Ps decay interact in the plastic scintillators predominantly via the Compton effect, making the direct measurement of their energy impossible. Nevertheless, it is shown in this paper that the J-PET scanner will enable studies of the o-Ps$\to3γ$ decays with angular and energy resolution equal to $σ(θ) \approx 0.4^{\circ}$ and $σ(E) \approx 4.1$ keV, respectively. An order of magnitude shorter decay time of signals from plastic scintillators with respect to the inorganic crystals results not only in better timing properties crucial for the reduction of physical and instrumental background, but also suppresses significantly the pileups, thus enabling compensation of the lower efficiency of the plastic scintillators by performing measurements with higher positron source activities.

physics.ins-det↗

First application of superconducting transition-edge-sensor microcalorimeters to hadronic-atom x-ray spectroscopy

High-resolution pionic-atom x-ray spectroscopy was performed with an x-ray spectrometer based on a 240-pixel array of superconducting transition-edge-sensor (TES) microcalorimeters at the piM1 beam line of the Paul Scherrer Institute. X-rays emitted by pionic carbon via the 4f->3d transition and the parallel 4d->3p transition were observed with a full-width-at-half-maximum energy resolution of 6.8 eV at 6.4 keV. Measured x-ray energies are consistent with calculated electromagnetic values which considered the strong-interaction effect assessed via the Seki-Masutani potential for the 3p energy level, and favor the electronic population of two filled 1s electrons in the K-shell. Absolute energy calibration with an uncertainty of 0.1 eV was demonstrated under a high-rate hadron beam condition of 1.45 MHz. This is the first application of a TES spectrometer to hadronic-atom x-ray spectroscopy and is an important milestone towards next-generation high-resolution kaonic-atom x-ray spectroscopy.

physics.ins-det↗

Angular distribution in s-channel formation of the pentaquark $Θ^+$ baryon

Using the DIANA data on the charge-exchange reaction $K^+n \rightarrow pK^0$ on a bound neutron, in which the s-channel formation of the pentaquark baryon $Θ^+(1538)$ has been observed, we analyze the dependence of the background-subtracted $Θ^+ \rightarrow pK^0$ signal on the $K^0$ emission angle in the $pK^0$ rest frame. In order to describe the observed $\cosΘ_K^\mathrm{cms}$ distribution, invoking the interference between the nonresonant s-wave and the $Θ^+$-mediated higher-wave contributions to the amplitude of the charge-exchange reaction is required at a 2.8$σ$ level. The spin--parity assignment of 1/2$^-$ for the $Θ^+$ baryon is ruled out at a statistical level of 2.9 standard deviations. A physically-meaningful selection in $\cosΘ_K^\mathrm{cms}$ based on the observed angular dependence of the $Θ^+ \rightarrow pK^0$ signal allows to boost the statistical significance of the signal up to 7.1 standard deviations. This is far in excess of previously reported signals and renders the $Θ^+$ existence more credible.

hep-ex↗

$K$-series X-ray yield measurement of kaonic hydrogen atoms in a gaseous target

We measured the $K$-series X-rays of the $K^{-}p$ exotic atom in the SIDDHARTA experiment with a gaseous hydrogen target of 1.3 g/l, which is about 15 times the $ρ_{\rm STP}$ of hydrogen gas. At this density, the absolute yields of kaonic X-rays, when a negatively charged kaon stopped inside the target, were determined to be 0.012$^{+0.004}_{-0.003}$ for $K_α$ and 0.043$^{+0.012}_{-0.011}$ for all the $K$-series transitions $K_{tot}$. These results, together with the KEK E228 experiment results, confirm for the first time a target density dependence of the yield predicted by the cascade models, and provide valuable information to refine the parameters used in the cascade models for the kaonic atoms.

nucl-ex↗

Strong interaction studies with kaonic atoms

The strong interaction of antikaons with nucleons and nuclei in the low-energy regime represents an active research field connected intrinsically with few-body physics. There are important open questions like the question of antikaon nuclear bound states. A unique and rather direct experimental access to the antikaon-nucleon scattering lengths is provided by precision X-ray spectroscopy of transitions in low-lying states of light kaonic atoms like kaonic hydrogen isotopes. In the SIDDHARTA experiment at the electron-positron collider DAFNE of LNF-INFN we measured the most precise values of the strong interaction observables, i.e. the strong interaction on the 1s ground state of the electromagnetically bound kaonic hydrogen atom leading to a hadronic shift and a hadronic broadening of the 1s state. The SIDDHARTA result triggered new theoretical work which achieved major progress in the understanding of the low-energy strong interaction with strangeness. Antikaon-nucleon scattering lengths have been calculated constrained by the SIDDHARTA data on kaonic hydrogen. For the extraction of the isospin-dependent scattering lengths a measurement of the hadronic shift and width of kaonic deuterium is necessary. Therefore, new X-ray studies with the focus on kaonic deuterium are in preparation (SIDDHARTA2). Many improvements in the experimental setup will allow to measure kaonic deuterium which is challenging due to the anticipated low X-ray yield. Especially important are the data on the X-ray yields of kaonic deuterium extracted from a exploratory experiment within SIDDHARTA.

nucl-ex↗

Structure near $K^-$+$p$+$p$ threshold in the in-flight $^3$He$(K^-,Λp)n$ reaction

To search for an S= -1 di-baryonic state which decays to $Λp$, the $ {\rm{}^3He}(K^-,Λp)n_{missing}$ reaction was studied at 1.0 GeV/$c$. Unobserved neutrons were kinematically identified from the missing mass $M_X$ of the $ {\rm{}^3He}(K^-,Λp)X$ reaction in order to have a large acceptance for the $Λpn$ final state. The observed $Λp n$ events, distributed widely over the kinematically allowed region of the Dalitz plot, establish that the major component comes from a three nucleon absorption process. A concentration of events at a specific neutron kinetic energy was observed in a region of low momentum transfer to the $Λp$. To account for the observed peak structure, the simplest S-wave pole was assumed to exist in the reaction channel, having Breit-Wigner form in energy and with a Gaussian form-factor. A minimum $χ^2$ method was applied to deduce its mass $M_X\ =$ 2355 $ ^{+ 6}_{ - 8}$ (stat.) $ \pm 12$ (syst.) MeV/c$^2$, and decay-width $Γ_X\ = $ 110 $ ^{+ 19}_{ - 17}$ (stat.) $ \pm 27$ (syst.) MeV/c$^2$, respectively. The form factor parameter $Q_X \sim$ 400 MeV/$c$ implies that the range of interaction is about 0.5

nucl-ex↗

Potential of the J-PET detector for studies of discrete symmetries in decays of positronium atom - a purely leptonic system

The Jagiellonian Positron Emission Tomograph (J-PET) was constructed as a prototype of the cost-effective scanner for the simultaneous metabolic imaging of the whole human body. Being optimized for the detection of photons from the electron-positron annihilation with high time- and high angular-resolution, it constitutes a multi-purpose detector providing new opportunities for studying the decays of positronium atoms. Positronium is the lightest purely leptonic object decaying into photons. As an atom bound by a central potential it is a parity eigenstate, and as an atom built out of an electron and an anti-electron it is an eigenstate of the charge conjugation operator. Therefore, the positronium is a unique laboratory to study discrete symmetries whose precision is limited in principle by the effects due to the weak interactions expected at the level of (~10$^{-14}$) and photon-photon interactions expected at the level of (~10$^{-9}$). The J-PET detector enables to perform tests of discrete symmetries in the leptonic sector via the determination of the expectation values of the discrete-symmetries-odd operators, which may be constructed from the spin of ortho-positronium atom and the momenta and polarization vectors of photons originating from its annihilation. In this article we present the potential of the J-PET detector to test the C, CP, T and CPT symmetries in the decays of positronium atoms.

nucl-ex↗

VIP 2: Experimental tests of the Pauli Exclusion Principle for electrons

The Pauli Exclusion Principle (PEP) was famously discovered in 1925 by the austrian physicist Wolfgang Pauli. Since then, it underwent several experimental tests. Starting in 2006, the VIP (Violation of the Pauli Principle) experiment looked for 2p to 1s X-ray transitions in copper, where 2 electrons are present in the 1s state before the transition happens. These transitions violate the PEP, and the lack of detection of the corresponding X-ray photons lead to a preliminary upper limit for the violation of the PEP of 4.7 * 10^(-29). The follow-up experiment VIP 2 is currently in the testing phase and will be transported to its final destination, the underground laboratory of Gran Sasso in Italy, in autumn 2015. Several improvements compared to its predecessor like the use of new X-ray detectors and active shielding from background gives rise to a goal for the improvement of the upper limit of the probability for the violation of the Pauli Exclusion Principle of 2 orders of magnitude.

physics.ins-det↗

Application of photon detectors in the VIP2 experiment to test the Pauli Exclusion Principle

The Pauli Exclusion Principle (PEP) was introduced by the austrian physicist Wolfgang Pauli in 1925. Since then, several experiments have checked its validity. From 2006 until 2010, the VIP (VIolation of the Pauli Principle) experiment took data at the LNGS underground laboratory to test the PEP. This experiment looked for electronic 2p to 1s transitions in copper, where 2 electrons are in the 1s state before the transition happens. These transitions violate the PEP. The lack of detection of X-ray photons coming from these transitions resulted in a preliminary upper limit for the violation of the PEP of $4.7 \times 10^{-29}$. Currently, the successor experiment VIP2 is under preparation. The main improvements are, on one side, the use of Silicon Drift Detectors (SDDs) as X-ray photon detectors. On the other side an active shielding is implemented, which consists of plastic scintillator bars read by Silicon Photomultipliers (SiPMs). The employment of these detectors will improve the upper limit for the violation of the PEP by around 2 orders of magnitude.

physics.ins-det↗

Spontaneously emitted X-rays: an experimental signature of the dynamical reduction models

We present the idea of searching for X-rays as a signature of the mechanism inducing the spontaneous collapse of the wave function. Such a signal is predicted by the continuous spontaneous localization theories, which are solving the "measurement problem" by modifying the Schrodinger equation. We will show some encouraging preliminary results and discuss future plans and strategy.

quant-ph↗

Searches for the Violation of Pauli Exclusion Principle at LNGS in VIP(-2) experiment

The VIP (Violation of Pauli exclusion principle) experiment and its follow-up experiment VIP-2 at the Laboratori Nazionali del Gran Sasso (LNGS) search for X-rays from Cu atomic states that are prohibited by the Pauli Exclusion Principle (PEP). The candidate events, if they exist, will originate from the transition of a $2p$ orbit electron to the ground state which is already occupied by two electrons. The present limit on the probability for PEP violation for electron is 4.7 $\times10^{-29}$ set by the VIP experiment. With upgraded detectors for high precision X-ray spectroscopy, the VIP-2 experiment will improve the sensitivity by two orders of magnitude.

physics.ins-det↗

Absolute Energy Calibration of X-ray TESs with 0.04 eV Uncertainty at 6.4 keV in a Hadron-Beam Environment

A performance evaluation of superconducting transition-edge sensors (TESs) in the environment of a pion beam line at a particle accelerator is presented. Averaged across the 209 functioning sensors in the array, the achieved energy resolution is 5.2 eV FWHM at Co $K_α$ (6.9 keV) when the pion beam is off and 7.3 eV at a beam rate of 1.45 MHz. Absolute energy uncertainty of $\pm$0.04 eV is demonstrated for Fe $K_α$ (6.4 keV) with in-situ energy calibration obtained from other nearby known x-ray lines. To achieve this small uncertainty, it is essential to consider the non-Gaussian energy response of the TESs and thermal cross-talk pile-up effects due to charged-particle hits in the silicon substrate of the TES array.

physics.ins-det↗

Precision X-ray spectroscopy of kaonic atoms as a probe of low-energy kaon-nucleus interaction

In the exotic atoms where one atomic $1s$ electron is replaced by a $K^{-}$, the strong interaction between the $K^{-}$ and the nucleus introduces an energy shift and broadening of the low-lying kaonic atomic levels which are determined by only the electromagnetic interaction. By performing X-ray spectroscopy for Z=1,2 kaonic atoms, the SIDDHARTA experiment determined with high precision the shift and width for the $1s$ state of $K^{-}p$ and the $2p$ state of kaonic helium-3 and kaonic helium-4. These results provided unique information of the kaon-nucleus interaction in the low energy limit.

nucl-ex↗

Shedding New Light on Kaon-Nucleon/Nuclei Interaction and Its Astrophysical Implications with the AMADEUS Experiment at DAFNE

The AMADEUS experiment deals with the investigation of the low-energy kaon-nuclei hadronic interaction at the DAΦNE collider at LNF-INFN, which is fundamental to respond longstanding questions in the non-perturbative QCD strangeness sector. The antikaon-nucleon potential is investigated searching for signals from possible bound kaonic clusters, which would open the possibility for the formation of cold dense baryonic matter. The confirmation of this scenario may imply a fundamental role of strangeness in astrophysics. AMADEUS step 0 consisted in the reanalysis of 2004/2005 KLOE dataset, exploiting K- absorptions in H, 4He, 9Be and 12C in the setup materials. In this paper, together with a review on the multi-nucleon K- absorption and the particle identification procedure, the first results on the Σ0-p channel will be presented including a statistical analysis on the possible accomodation of a deeply bound state

nucl-ex↗

K$^-$ absorption on two nucleons and ppK$^-$ bound state search in the $Σ^0$p final state

We report the measurement of K$^-$ absorption processes in the $Σ^0$p final state and the first exclusive measurement of the two nucleon absorption (2NA) with the KLOE detector. The 2NA process without further interactions is found to be 12\% of the sum of all other contributing processes, including absorption on three and more nucleons or 2NA followed by final state interactions with the residual nucleons. We also determine the possible contribution of the ppK$^-$ bound state to the $Σ^0$p final state. A yield of ppK$^- /\mathrm{K^-_{stop}}$ is found to be $(0.044 \pm 0.009\, stat ^{+ 0.004} _{- 0.005} \,syst) \cdot 10^{-2}$ but its statistical significance based on an F-test is only 1$σ$.

nucl-ex↗

Recovery Time Measurements of Silicon Photomultipliers Using a Pulsed Laser

We performed an experimental study to determine the pixel recovery time of various Multi Pixel Photon Counters (MPPCs) in order to characterize their rate capability and double-hit resolution. The recovery time constant and its dependence on the operating voltage has been evaluated by measuring the photosensor response to two consecutive laser pulses with varying relative time differences of a few ns (2-3 ns) up to some 100 ns using a waveform analysis technique. A Monte Carlo simulation tool is being developed to model the MPPC recovery process and interpret experimental data. In this context, the influence of after-pulsing, cross-talk and dark-noise on the recovery process can be studied.