Searcharxiv⌕ Search

arXiv subjects

C. P. Bidinosti

Publications and source records attributed to C. P. Bidinosti.

12 recordsLinked to original sources

Characterization of electroless nickel-phosphorus plating for ultracold-neutron storage

Electroless nickel plating is an established industrial process that provides a robust and relatively low-cost coating suitable for transporting and storing ultracold neutrons (UCN). Using roughness measurements and UCN-storage experiments we characterized UCN guides made from polished aluminum or stainless-steel tubes plated by several vendors. All electroless nickel platings were similarly suited for UCN storage with an average loss probability per wall bounce of $2.8\cdot10^{-4}$ to $4.1\cdot10^{-4}$ for energies between 90 neV and 190 neV, or a ratio of imaginary to real Fermi potential $η$ of $1.7\cdot10^{-4}$ to $3.3\cdot10^{-4}$. Measurements at different elevations indicate that the energy dependence of UCN losses is well described by the imaginary Fermi potential. Some special considerations are required to avoid an increase in surface roughness during the plating process and hence a reduction in UCN transmission. Increased roughness had only a minor impact on storage properties. Based on these findings we chose a vendor to plate the UCN-production vessel that will contain the superfluid-helium converter for the new TRIUMF UltraCold Advanced Neutron (TUCAN) source, achieving acceptable UCN-storage properties with ${η=3.5(5)\cdot10^{-4}}$.

nucl-ex↗

Inside Out: Transforming Images of Lab-Grown Plants for Machine Learning Applications in Agriculture

Machine learning tasks often require a significant amount of training data for the resultant network to perform suitably for a given problem in any domain. In agriculture, dataset sizes are further limited by phenotypical differences between two plants of the same genotype, often as a result of differing growing conditions. Synthetically-augmented datasets have shown promise in improving existing models when real data is not available. In this paper, we employ a contrastive unpaired translation (CUT) generative adversarial network (GAN) and simple image processing techniques to translate indoor plant images to appear as field images. While we train our network to translate an image containing only a single plant, we show that our method is easily extendable to produce multiple-plant field images. Furthermore, we use our synthetic multi-plant images to train several YoloV5 nano object detection models to perform the task of plant detection and measure the accuracy of the model on real field data images. Including training data generated by the CUT-GAN leads to better plant detection performance compared to a network trained solely on real data.

cs.CV↗

A fast-switching magnet serving a spallation-driven ultracold neutron source

A fast-switching, high-repetition-rate magnet and power supply have been developed for and operated at TRIUMF, to deliver a proton beam to the new ultracold neutron (UCN) facility. The facility possesses unique operational requirements: a time-averaged beam current of 40~$μ$A with the ability to switch the beam on or off for several minutes. These requirements are in conflict with the typical operation mode of the TRIUMF cyclotron which delivers nearly continuous beam to multiple users. To enable the creation of the UCN facility, a beam-sharing arrangement with another facility was made. The beam sharing is accomplished by the fast-switching (kicker) magnet which is ramped in 50~$μ$s to a current of 193~A, held there for approximately 1~ms, then ramped down in the same short period of time. This achieves a 12~mrad deflection which is sufficient to switch the proton beam between the two facilities. The kicker magnet relies on a high-current, low-inductance coil connected to a fast-switching power supply that is based on insulated-gate bipolar transistors (IGBTs). The design and performance of the kicker magnet system and initial beam delivery results are reported.

physics.acc-ph↗

Analytic models of magnetically enclosed spherical and solenoidal coils

We provide analytic solutions of the net magnetic field generated by spherical and solenoidal coils enclosed in highly-permeable, coaxial magnetic shields. We consider both spherical and cylindrical shields in the case of the spherical coil and only cylindrical shields for the solenoidal coil. Comparisons of field homogeneity are made and we find that the solenoidal coil produces the more homogeneous field for a given number of windings. The models are useful as theoretical and conceptual guides for coil design, as well as for benchmarking finite-element analysis. We also demonstrate how the models can be generalized to explore field inhomogeneities related to winding misplacement.

physics.acc-ph↗

First ultracold neutrons produced at TRIUMF

We installed a source for ultracold neutrons at a new, dedicated spallation target at TRIUMF. The source was originally developed in Japan and uses a superfluid-helium converter cooled to 0.9$\,$K. During an extensive test campaign in November 2017, we extracted up to 325000 ultracold neutrons after a one-minute irradiation of the target, over three times more than previously achieved with this source. The corresponding ultracold-neutron density in the whole production and guide volume is 5.3$\,$cm$^{-3}$. The storage lifetime of ultracold neutrons in the source was initially 37$\,$s and dropped to 24$\,$s during the eighteen days of operation. During continuous irradiation of the spallation target, we were able to detect a sustained ultracold-neutron rate of up to 1500$\,$s$^{-1}$. Simulations of UCN production, UCN transport, temperature-dependent UCN yield, and temperature-dependent storage lifetime show excellent agreement with the experimental data and confirm that the ultracold-neutron-upscattering rate in superfluid helium is proportional to $T^7$.

physics.ins-det↗

Development of co-located ${}^{129}$Xe and ${}^{131}$Xe nuclear spin masers with external feedback scheme

We report on the operation of co-located ${}^{129}$Xe and ${}^{131}$Xe nuclear spin masers with an external feedback scheme, and discuss the use of ${}^{131}$Xe as a comagnetometer in measurements of the ${}^{129}$Xe spin precession frequency. By applying a correction based on the observed change in the ${}^{131}$Xe frequency, the frequency instability due to magnetic field and cell temperature drifts are eliminated by two orders of magnitude. The frequency precision of 6.2 $μ$Hz is obtained for a 10$^4$ s averaging time, suggesting the possibility of future improvement to $\approx$ 1 nHz by improving the signal-to-noise ratio of the observation.

physics.atom-ph↗

Sensitivity of Fields Generated within Magnetically Shielded Volumes to Changes in Magnetic Permeability

Future experiments seeking to measure the neutron electric dipole moment (nEDM) require stable and homogeneous magnetic fields. Normally these experiments use a coil internal to a passively magnetically shielded volume to generate the magnetic field. The stability of the magnetic field generated by the coil within the magnetically shielded volume may be influenced by a number of factors. The factor studied here is the dependence of the internally generated field on the magnetic permeability $μ$ of the shield material. We provide measurements of the temperature-dependence of the permeability of the material used in a set of prototype magnetic shields, using experimental parameters nearer to those of nEDM experiments than previously reported in the literature. Our measurements imply a range of $\frac{1}μ\frac{dμ}{dT}$ from 0-2.7\%/K. Assuming typical nEDM experiment coil and shield parameters gives $\fracμ{B_0}\frac{dB_0}{dμ}=0.01$, resulting in a temperature dependence of the magnetic field in a typical nEDM experiment of $\frac{dB_0}{dT}=0-270$~pT/K for $B_0=1~μ$T. The results are useful for estimating the necessary level of temperature control in nEDM experiments.

physics.ins-det↗

Passive Magnetic Shielding in Gradient Fields

The effect of passive magnetic shielding on dc magnetic field gradients imposed by both external and internal sources is studied. It is found that for concentric cylindrical or spherical shells of high permeability material, higher order multipoles in the magnetic field are shielded progressively better, by a factor related to the order of the multipole. In regard to the design of internal coil systems for the generation of uniform internal fields, we show how one can take advantage of the coupling of the coils to the innermost magnetic shield to further optimize the uniformity of the field. These results demonstrate quantitatively a phenomenon that was previously well-known qualitatively: that the resultant magnetic field within a passively magnetically shielded region can be much more uniform than the applied magnetic field itself. Furthermore we provide formulae relevant to active magnetic compensation systems which attempt to stabilize the interior fields by sensing and cancelling the exterior fields close to the outermost magnetic shielding layer. Overall this work provides a comprehensive framework needed to analyze and optimize dc magnetic shields, serving as a theoretical and conceptual design guide as well as a starting point and benchmark for finite-element analysis.

physics.ins-det↗

Phenomenology of a-axis and b-axis charge dynamics from microwave spectroscopy of highly ordered YBa2Cu3O6.50 and YBa2Cu3O6.993

Extensive measurements of the microwave conductivity of highly pure and oxygen-ordered \YBCO single crystals have been performed as a means of exploring the intrinsic charge dynamics of a d-wave superconductor. Broadband and fixed-frequency microwave apparatus together provide a very clear picture of the electrodynamics of the superconducting condensate and its thermally excited nodal quasiparticles. The measurements reveal the existence of very long-lived excitations deep in the superconducting state, as evidenced by sharp cusp-like conductivity spectra with widths that fall well within our experimental bandwidth. We present a phenomenological model of the microwave conductivity that captures the physics of energy-dependent quasiparticle dynamics in a d-wave superconductor which, in turn, allows us to examine the scattering rate and oscillator strength of the thermally excited quasiparticles as functions of temperature. Our results are in close agreement with the Ferrell-Glover-Tinkham sum rule, giving confidence in both our experiments and the phenomenological model. Separate experiments for currents along the $\hat a$ and $\hat b$ directions of detwinned crystals allow us to isolate the role of the CuO chain layers in \YBCO, and a model is presented that incorporates both one-dimensional conduction from the chain electrons and two-dimensional transport associated with the \cuplane plane layers.

cond-mat.supr-con↗

MRI of the lung using hyperpolarized He-3 at very low magnetic field (3 mT)

Optical pumping of He-3 produces large (hyper) nuclear-spin polarizations independent of the magnetic resonance imaging (MRI) field strength. This allows lung MRI to be performed at reduced fields with many associated benefits, such as lower tissue susceptibility gradients and decreased power absorption rates. Here we present results of 2D imaging as well as accurate 1D gas diffusion mapping of the human lung using He-3 at very low field (3 mT). Furthermore, measurements of transverse relaxation in zero applied gradient are shown to accurately track pulmonary oxygen partial pressure, opening the way for novel imaging sequences.

physics.med-ph↗

CeCoIn5 - a quantum critical superfluid

We have made the first complete measurements of the London penetration depth $λ(T)$ of CeCoIn5, a quantum-critical metal where superconductivity arises from a non-Fermi-liquid normal state. Using a novel tunnel diode oscillator designed to avoid spurious contributions to $λ(T)$, we have established the existence of intrinsic and anomalous power-law behaviour at low temperature. A systematic analysis raises the possibility that the unusual observations are due to an extension of quantum criticality into the superconducting state.

cond-mat.supr-con↗

Measurements of the Magnetic Field Dependence of Lambda in YBa_2Cu_3O_6.95: Results as a Function of Temperature and Field Orientation

We present measurements of the magnetic field dependence of the penetration depth Lambda(H) for untwinned YBa_2Cu_3O_6.95 for temperatures from 1.2 to 70 K in dc fields up to 42 gauss and directions 0, 45 and 90 degrees with respect to the crystal b-axis. The experiment uses an ac susceptometer with fields applied parallel to the ab-plane of thin platelet samples. The resolution is about 0.15 Angstroms in zero dc field, degrading to 0.2 or 0.3 Angstroms at the higher fields. At low temperatures the field dependencies are essentially linear in H, ranging from 0.04 Angstroms/gauss for Delta-Lambda_a to 0.10 Angstroms/gauss for Delta-Lambda_b, values comparable to the T=0 Yip and Sauls prediction for a d-wave superconductor. However, the systematics versus temperature and orientation do not agree with the d-wave scenario probably due, in part, to residual sample problems.

cond-mat.supr-con↗