SearcharxivSearch

arXiv subjects

Catalina Curceanu

Publications and source records attributed to Catalina Curceanu.

At least 19 recordsLinked to original sources

First measurement of kaonic deuterium X-ray transitions

The study of the strong interaction among hadrons at low energies remains one of the key challenges in fundamental physics because of its non-perturbative nature, which makes theoretical descriptions strongly dependent on experimental input. Although substantial progress has been made for systems involving up and down quarks, theoretical models in the strangeness sector continue to face limitations due to the lack of experimental data. Kaonic atoms provide a powerful tool to study the low-energy strong interaction with strangeness through the energy shifts and widths induced on their lowest atomic levels. In this context, kaonic deuterium X-ray spectroscopy has long represented one of the major open challenges in hadronic-atom physics because of its extremely low X-ray yield. This measurement is particularly important because it gives access to the experimentally inaccessible $K^-n$ interaction at threshold energy. Here, we report the first observation of kaonic deuterium X-ray transitions, performed with the SIDDHARTA-2 experiment at the DA$\Phi$NE collider. We determine the strong-interaction shift and width of the $1s$ level to be $\varepsilon_{1s}=-810.9\pm24.5\,(\mathrm{stat})\pm2.1\,(\mathrm{syst})\,\mathrm{eV}$ and $\Gamma_{1s}=812\pm97\,(\mathrm{stat})\pm33\,(\mathrm{syst})\,\mathrm{eV}$, respectively. This measurement constitutes the most precise experimental determination of the $K^-d$ strong interaction at threshold and allows discrimination among competing theoretical models. Combined with the kaonic hydrogen measurement, this result provides the experimental input required to determine the isospin-dependent $K^-N$ scattering lengths, with implications for the description of the nature of the first predicted hadronic molecular state, the $\Lambda(1405)$, and neutron-rich matter.

nucl-ex

Atomic correlation effects in collapse-induced spontaneous radiation

Collapse models introduce stochastic and nonlinear modifications in the quantum dynamics, predicting observable effects, such as spontaneous radiation from charged particles, which can be used to constrain their parameters. Recently, attention has focused on the 1-100 keV energy range, where the wavelength of the emitted photons becomes comparable to atomic dimensions, making the emission sensitive to atomic structure and leading to model-dependent behaviors that enable their discrimination. Here, we derive a general expression for the spontaneous emission rate for arbitrary noise, providing a framework that systematically incorporates the atomic structure through the radial distribution of the emitters, modulated by the specific collapse model. The formalism recovers previous results in the appropriate limits and naturally includes new low-energy effects, such as cancellation mechanisms arising from charge correlations. We evaluate the rates for germanium and xenon within the Di\'osi-Penrose and Continuous Spontaneous Localization models, showing how these correlations modify the predicted emission rates. This approach provides a unified framework to account for atomic effects and enables more robust, material-dependent experimental constraints on collapse model parameters.

quant-ph

Experimental determination of the Dalitz plot for positronium decay using the J-PET detection system

We present the first measurements of the Dalitz plot for ortho-positronium annihilation to three photons. Our measurements, accurate to about 3% statistical and 2-3% systematic uncertainty in angular representation over almost the entire available phase space, were performed using the Jagiellonian Positron Emission Tomograph (J-PET) based on organic scintillator strips. Until now, the Dalitz plot for the three-body positronium decay has been poorly explored. The new measurements presented here are consistent with both the leading-order and next-to-leading order QED predictions for the Dalitz plot.

nucl-ex

First-in-human quantum entanglement imaging

Annihilation photons are quantum-entangled in polarization, a phenomenon that has not been exploited in medical diagnostics so far. We present the first in vivo imaging of the degree of quantum entanglement of photons originating from positron-electron annihilation within a human subject. This study utilized the Jagiellonian Positron Emission Tomography (J-PET) scanner, constructed from plastic scintillators. In plastics, annihilation photons interact primarily via the Compton effect, which provides simultaneous information regarding the photon interaction position and time, as well as the photon polarization plane. The patient was injected with a DOTA-TATE radiopharmaceutical labeled with the $^{68}$Ga radionuclide. Using the J-PET scanner, we determined the image of the radiopharmaceutical uptake and, simultaneously, the image of the degree of quantum entanglement. The latter was determined from the relative angle between the polarization planes of the annihilation photons. The values of the degree of quantum entanglement extracted for the liver and the spleen are smaller than those predicted for maximally entangled two-photon states, yet larger than expected for separable photons. This demonstration opens new perspectives for the application of quantum entanglement in clinical diagnostics.

physics.med-ph

Kaonic Copper and Fluorine Absolute Yields Measurement with a CZT-based Detection System at DA$\Phi$NE

\noindent In this work, new measurements of absolute X-ray yields for several transitions in kaonic copper and, for the first time, in kaonic fluorine are reported. The data were collected by the SIDDHARTA-2 collaboration at the DA$\Phi$NE collider using a novel room-temperature Cadmium Zinc Telluride (CZT) detection system. Detection efficiencies were evaluated through a dedicated Geant4 Monte Carlo simulation of the full experimental setup, enabling the extraction of absolute yields per stopped kaon. \noindent The measured yields exhibit a systematic dependence on the principal quantum number, reflecting the interplay between radiative transitions, Auger de-excitation, and strong-interaction-induced nuclear capture. In kaonic fluorine, a suppression of the 4$\to$3 transition yield relative to higher-n transitions is observed, providing evidence for the onset of strong-interaction effects already at the $n=4$ level. From this behaviour, a conservative lower limit on the corresponding strong-interaction width is derived. \noindent These results provide new quantitative constraints for cascade models of exotic atoms and extend experimental access to intermediate atomic levels where strong-interaction effects are not directly observable via level shifts and widths. They also establish CZT-based detection as a powerful and versatile approach for high-resolution X-ray spectroscopy of kaonic atoms in collider environments.

nucl-ex

Probing Nuclear Structure with Kaonic Atoms through E2 Resonance Mixing

Kaonic atoms provide a unique laboratory to investigate the interplay between atomic, nuclear, and strong-interaction physics. In heavy nuclei, atomic transitions can couple to low-lying collective nuclear excitations via the electric quadrupole interaction. When the energy difference between two kaonic atomic levels approaches that of a nuclear $2^+$ excitation, a resonant configuration mixing may occur, known as the E2 nuclear resonance effect. In this work, we investigate the conditions for E2 resonance in kaonic molybdenum isotopes. We describe the mixing using state-of-the-art Dirac-Fock calculations combined with updated nuclear structure inputs, including recent electric quadrupole transition strength values and excitation energies. We evaluate the sensitivity of the effect to key parameters, assess its observability in future experiments such as the EXKALIBUR program, and discuss its impact on cascade dynamics. Our results demonstrate the potential of kaonic atoms as a probe of nuclear structure, complementary to conventional nuclear spectroscopy.

nucl-ex

When identical particles cease to be indistinguishable: violation of statistics in quantum spacetime

Quantum gravity may modify the fundamental symmetries that govern identical particles. In particular, noncommutative spacetime frameworks predict deformations of Bose and Fermi statistics. Here we develop a relativistic quantum field theory based on the most general oscillator algebra compatible with $\theta$-deformed Poincar\'e symmetry. This construction generalizes twisted statistics to a class of quon-like deformations allowing non-involutive particle exchange. We show that the resulting theory is consistent at both the free and interacting levels and derive its implications for atomic systems. Purely twisted statistics predicts Pauli-forbidden atomic transitions at rates incompatible with experiments. By contrast, a class of quon deformations suppresses such processes by powers of the noncommutativity scale, but only if superselection rules between permutation-symmetry sectors are violated. This implies an effective breakdown of particle indistinguishability and provides theoretical motivation for high-precision experimental tests of the Pauli exclusion principle.

hep-th

Extended X-ray energy characterization of SIDDHARTA-2 large-area Silicon Drift Detectors up to 50 keV

The SIDDHARTA-2 experiment at the DA$\Phi$NE collider of INFN-LNF performs high precision light kaonic atoms X-ray spectroscopy to investigate the kaon-nucleon(s) strong interaction in the low-energy (O(10 keV)) regime. A large area Silicon Drift Detectors (SDDs) system has been developed to carry out these measurements. The collaboration aims to extend the measurements campaign to higher mass kaonic atoms, which exhibit transition lines at increased X-ray energies. In this context, the spectroscopic response of the SIDDHARTA-2 SDD system was investigated in terms of linearity and energy resolution up to 50 keV. An accuracy of the energy calibration procedure $\Delta E/E < 10^{-3}$ was achieved.

physics.ins-det

First ex-vivo positronium imaging of tissues with modular J-PET scanner using $^{44}$Sc radionuclide

This study presents the first ex-vivo positronium imaging of human tissues using the modular J-PET scanner with the $^{44}$Sc radionuclide. The $^{44}$Sc isotope was produced via the $^{44}$Ca(p, n)$^{44}$Sc nuclear reaction and used to perform positronium imaging of phantom composed of human adipose tissue, cardiac myxoma tissue, thrombi blood clot, and also porous polymer XAD4, and a certified reference material (CRM) made from fused silica. The experiment demonstrates the suitability of $^{44}$Sc as a positron source for positronium imaging. The performance of J-PET for positronium imaging with $^{44}$Sc was validated by proper reconstruction of the mean orthopositronium lifetime for CRM material and XAD-4 polymer. The mean ortho-positronium (oPs) lifetimes determined for adipose tissue, cardiac myxoma tissues and thrombi were consistent with results of previous experiments. The study highlights the potential $^{44}$Sc radionuclide for positronium lifetime imaging (PLI).

physics.med-ph

Feasibility study of the positronium lifetime imaging with the Biograph Vision Quadra and J-PET tomographs

Background: After its first ex-vivo and in-vivo demonstration, Positronium Lifetime Imaging (PLI) has received considerable interest as a potential new diagnostic biomarker. High sensitivity Positron Emission Tomography (PET) systems are needed for PLI since it requires simultaneous registration of annihilation photons and prompt gamma. In this simulation-based study, a~feasibility of PLI with the long axial field-of-view Biograph Vision Quadra (Quadra) and the Total Body J-PET scanner was investigated. Methods: The study was performed using the GATE software. Background radiation, present within the Quadra tomograph, was added to the simulation. First, the optimal placement of the energy window for the registration of the prompt gamma was investigated. Next, the organ-wise sensitivity of Quadra was calculated for the $^{68}$Ga, $^{44}$Sc, $^{22}$Na and $^{124}$I radioisotopes. Finally, the sensitivity for the scandium isotope was compared to the sensitivities obtainable with the Total Body J-PET scanner, as well as with the modular J-PET prototype. Results: The PLI sensitivities for the Quadra with the background radiation are estimated to 9.22(3), 10.46(4), 5.91(3), and 15.39(4) cps/kBq for the $^{44}$Sc, $^{68}$Ga, $^{22}$Na and $^{124}$I radioisotopes, respectively. The highest sensitivity was obtained when the energy window for the deexcitation photon is adjacent to the energy window for the annihilation photons. The determined PLI sensitivities with Quadra and the Total Body J-PET are in the order of sensitivities of standard PET imaging with the short axial field-of-view ($\sim$20 cm) PET scanners. Conclusion: The organ-wise PLI sensitivity of Quadra has been computed for the $^{68}$Ga, $^{44}$Sc, $^{22}$Na and $^{124}$I radioisotopes. A sensitivity gain by a factor of 150 was estimated relative to the modular J-PET system previously used for the first in-vivo PLI.

physics.med-ph

Experimental exclusion of a generalized K\'arolyh\'azy gravity-induced decoherence model

We report new experimental constraints on the generalized version of the gravity-induced decoherence model originally proposed by K\'arolyh\'azy. Using data collected by the VIP Collaboration at the INFN Gran Sasso National Laboratory with a high-purity germanium detector, we derive an improved lower bound on the spatial correlation length $R_K$ characterizing metric fluctuations in the model. We obtain a bound $R_K > 4.64$ m (95\% C.L.), which exceeds by more than an order of magnitude the previous experimental limit. When combined with the theoretical upper bound $R_K <1.98$ m derived from macroscopic localization requirements, our result excludes the generalized K\'arolyh\'azy model. The same conclusion applies to an associated non-Markovian formulation of the Continuous Spontaneous Localization (CSL) model. Our findings significantly tighten experimental constraints on gravity-related decoherence scenarios and demonstrate the sensitivity of underground low-background experiments to foundational modifications of quantum mechanics.

quant-ph

First Positronium Lifetime Imaging using $^{52}$Mn and $^{55}$Co with a plastic-based PET scanner

Positronium Lifetime Imaging (PLI) extends positron emission tomography by using the lifetime of positronium atoms as a probe of tissue molecular architecture. In this work, we report the first PLI measurements performed with $^{52}$Mn and $^{55}$Co using the modular J-PET. Four samples were studied in each experiment: two Certified Reference Materials (polycarbonate and fused silica) and two human tissues (cardiac myxoma and adipose). The selection of PLI events was based on the registration of two 511~keV annihilation photons and one prompt gamma in triple coincidence. From the resulting lifetime spectra we extracted the mean ortho-positronium lifetime $\tau_{\text{oPs}}$ and the mean positron lifetime $\Delta T_{\text{mean}}$ for each sample. The measured values of $\tau_{\text{oPs}}$ in polycarbonate using both isotopes matches well with the certified reference values. Furthermore, $^{55}$Co reproduced identical results for fused-silica measurements at their respective uncertainty levels. In contrast, measurements with $^{52}$Mn in fused silica show a minor deviation, which could be caused by the Parafilm spacer. In myxoma and adipose tissue, the reduced $\tau_{\text{oPs}}$ values are mainly linked to the long storage history of the samples rather than to the choice of isotope. Comparing peak-to-background ratios and spectral purity, $^{55}$Co provides cleaner PLI data under the same experimental conditions. Although $^{52}$Mn offers a longer half-life and a multi gamma cascade enhancing $\beta^{+}$ + $\gamma$ coincidences, but at the expense of higher background. In this study, we demonstrate that the applied selection criteria on the data measured with the modular J-PET can be used for PLI studies even with radionuclides with complex decay patterns.

physics.med-ph

Machine Learning Optimization of BEGe Detector Event Selection in the VIP Experiment

The VIP collaboration operates a Broad Energy Germanium detector at the Gran Sasso National Laboratory to measure radiation in the few keV to 100 keV range, aiming to search for spontaneous collapse induced radiation and atomic transitions that violate the Pauli Exclusion Principle. Here we present a machine learning based upgrade for the BEGe detector using an event selection strategy aimed at improving the efficiency in detecting low energy events down to 10 keV. The method employs a denoising autoencoder to suppress electronic and microphonic noises and to reconstruct pulse shapes, followed by a convolutional neural network that classifies waveforms as normal single site or events with anomalies. The workflow was validated on a dataset comprising more than 20000 waveforms recorded in 2021. The classifier achieves a receiver operating characteristic curve with an area under the curve of 0.99 and an accuracy of 95 percent. Applying this procedure lowers the minimum detectable energy of the final spectrum to approximately 10 keV. It also yields a measurable enhancement in spectral quality, including an improvement of about 14 percent in the signal to background ratio and a reduction of the energy resolution for the characteristic Pb and Bi gamma lines. These developments enhance the sensitivity of the BEGe detector to rare low energy signals and provide a scalable framework for future precision tests of quantum foundations in low background environments.

physics.ins-det

Recent Developments of the VOXES Von Hamos X-ray Spectrometer for Laboratory XES and XAS Studies

VOXES is a Von Hamos X-ray spectrometer developed at the INFN National Laboratories of Frascati for high-resolution laboratory X-ray spectroscopy in the 5--20~keV range. It uses curved mosaic crystals and motorized positioning stages to perform wavelength-dispersive X-ray fluorescence (WD-XRF) with sub-10~eV tunable resolution for extended and dilute samples. Recent developments include the integration of an energy-dispersive X-ray fluorescence (ED-XRF) line based on a silicon pin-diode detector, which enables flux monitoring and simultaneous ED and WD measurements. In addition, a dedicated liquid-sample holder has been introduced, and a Y-shaped support geometry, crucial for switching to a transmission layout, provides mechanical compatibility with laboratory XAS, now under implementation. These upgrades expand the versatility and automation of VOXES, strengthening its role as a table-top platform for laboratory X-ray spectroscopy.

physics.app-ph

CZT Detectors for kaonic atoms spectroscopy

Cadmium zinc telluride (CZT) detectors offer excellent room-temperature energy resolution, making them well suited for X- and $\gamma$-ray spectroscopy in challenging environments. Within the SIDDHARTA-2 program at the DA$\Phi$NE collider, a new CZT-based detection system has been developed to enable precision measurements of kaonic atom transitions in the intermediate mass range. In this work, we report the results of a calibration campaign performed with the collider operating, aimed at assessing the detector performance. A dedicated setup, including an array of quasi-hemispherical CZT sensors and a $^{152}$Eu source, was used to characterize the spectral response. The reconstructed emission lines were fitted with a model accounting for Gaussian response and incomplete charge recollection tails, and the detector linearity was evaluated by comparing the measured peak positions with their nominal energies. The results demonstrate that the CZT detector exhibits excellent linearity and stable operation with the collider on, confirming its suitability for future kaonic-atom spectroscopy at DA$\Phi$NE.

physics.ins-det

Time-based Selection of Kaonic Atom X-ray Events with Quasi-Hemispherical CZT Detectors at the DAFNE collider

This work presents the results of a time-based event selection for searching X-ray signals from kaonic atom X-ray transition using a single quasi-hemispherical Cadmium-Zinc-Telluride (CZT) detector at the DA$\Phi$NE collider. To mitigate the high background level in the measured X-ray spectrum, a dedicated event selection strategy was developed, exploiting the precise timing correlation between e+e- collisions and detector signals. This approach enabled, for the first time, the observation of two characteristic X-ray transitions from kaonic aluminum atoms using a CZT detector: for the 5-4 transition at 50~keV, 362~$\pm$~41~(stat.)~$\pm$~20~(sys.) signal events over 1698~$\pm$~197~(stat.)~$\pm$~25~(sys.) background events in 5$\sigma$ were observed, with a resolution of 9.2\%~FWHM; for the 4-3 transition at 106~keV, 295~$\pm$~50~(stat.)~$\pm$~20~(sys.) signal events over 2939~$\pm$~500~(stat.)~$\pm$~16~(sys.) background events in 5$\sigma$ were measured, with a resolution of 6.6 ~FWHM. A strong background suppression of approximately 95\% of the triggered data was achieved through this time-based selection. The demonstrated timing capability of the CZT detector proved highly effective in isolating time-correlated events within an 80 ns window, setting an important benchmark for the application of these semiconductors in timing-based X-ray spectroscopy. These results highlight the potential of CZT-based detection systems for future precision measurements in high-radiation environments, paving the way for compact, room-temperature X-ray and $\gamma$-ray spectrometers in fundamental physics and beyond.

physics.ins-det

EXKALIBUR: Towards a Kaonic Atoms Periodic Table to test Fundamental Interactions

Kaonic atoms, formed when a negatively charged kaon replaces an electron, provide a unique laboratory to test fundamental interactions at low energies. EXKALIBUR (EXtensive Kaonic Atoms research: from LIthium and Beryllium to URanium) is a program to perform systematic, high-precision X-ray spectroscopy of selected kaonic atoms across the periodic table at the DA$\Phi$NE accelerator at the National Laboratory of Frascati (INFN-LNF). Here, we outline its detector-driven strategy: Silicon Drift Detectors for 10-40 keV transitions in light targets (Li, Be, B, O), CdZnTe detectors for 40-300 keV lines in intermediate-$Z$ systems (Mg, Al, Si, S), and a High-Purity Germanium detector for high-$Z$ atoms (Se, Zr, Ta, Mo, W, Pb), complemented by VOXES, a high-resolution crystal spectrometer for sub-eV studies. EXKALIBUR plans to (i) reduce the charged-kaon mass uncertainty below 10 keV, (ii) produce a database of nuclear shifts and widths to constrain multi-nucleon K$^{-}$-nucleus interaction models, and (iii) provide precision data for testing bound-state QED in strong fields. We summarize the planned measurements and expected sensitivities within DA$\Phi$NE luminosities.

nucl-ex

First positronium imaging using $^{44}$Sc with the J-PET scanner: a case study on the NEMA-Image Quality phantom

Positronium Lifetime Imaging (PLI), an emerging extension of conventional positron emission tomography (PET) imaging, offers a novel window for probing the submolecular properties of biological tissues by imaging the mean lifetime of the positronium atom. Currently, the method is under rapid development in terms of reconstruction and detection systems. Recently, the first in vivo PLI of the human brain was performed using the J-PET scanner utilizing the $^{68}$Ga isotope. However, this isotope has limitations due to its comparatively low prompt gamma yields, which is crucial for positronium lifetime measurement. Among alternative radionuclides, $^{44}$Sc stands out as a promising isotope for PLI, characterized by a clinically suitable half-life (4.04 hours) emitting 1157 keV prompt gamma in 100% cases after the emission of the positron. This study reports the first experimental demonstration of PLI with $^{44}$Sc, carried out on a NEMA-Image Quality (IQ) phantom using the Modular J-PET tomograph-the first plastic scintillators-based PET scanner.

physics.med-ph