Searcharxiv⌕ Search

arXiv subjects

Catalina Curceanu

Publications and source records attributed to Catalina Curceanu.

At least 37 records · Page 2Linked to original sources

EXKALIBUR: Towards a Kaonic Atoms Periodic Table to test Fundamental Interactions

Kaonic atoms, formed when a negatively charged kaon replaces an electron, provide a unique laboratory to test fundamental interactions at low energies. EXKALIBUR (EXtensive Kaonic Atoms research: from LIthium and Beryllium to URanium) is a program to perform systematic, high-precision X-ray spectroscopy of selected kaonic atoms across the periodic table at the DA$Φ$NE accelerator at the National Laboratory of Frascati (INFN-LNF). Here, we outline its detector-driven strategy: Silicon Drift Detectors for 10-40 keV transitions in light targets (Li, Be, B, O), CdZnTe detectors for 40-300 keV lines in intermediate-$Z$ systems (Mg, Al, Si, S), and a High-Purity Germanium detector for high-$Z$ atoms (Se, Zr, Ta, Mo, W, Pb), complemented by VOXES, a high-resolution crystal spectrometer for sub-eV studies. EXKALIBUR plans to (i) reduce the charged-kaon mass uncertainty below 10 keV, (ii) produce a database of nuclear shifts and widths to constrain multi-nucleon K$^{-}$-nucleus interaction models, and (iii) provide precision data for testing bound-state QED in strong fields. We summarize the planned measurements and expected sensitivities within DA$Φ$NE luminosities.

nucl-ex↗

First positronium imaging using $^{44}$Sc with the J-PET scanner: a case study on the NEMA-Image Quality phantom

Positronium Lifetime Imaging (PLI), an emerging extension of conventional positron emission tomography (PET) imaging, offers a novel window for probing the submolecular properties of biological tissues by imaging the mean lifetime of the positronium atom. Currently, the method is under rapid development in terms of reconstruction and detection systems. Recently, the first in vivo PLI of the human brain was performed using the J-PET scanner utilizing the $^{68}$Ga isotope. However, this isotope has limitations due to its comparatively low prompt gamma yields, which is crucial for positronium lifetime measurement. Among alternative radionuclides, $^{44}$Sc stands out as a promising isotope for PLI, characterized by a clinically suitable half-life (4.04 hours) emitting 1157 keV prompt gamma in 100% cases after the emission of the positron. This study reports the first experimental demonstration of PLI with $^{44}$Sc, carried out on a NEMA-Image Quality (IQ) phantom using the Modular J-PET tomograph-the first plastic scintillators-based PET scanner.

physics.med-ph↗

Fundamental Limits on Clock Precision from Spacetime Uncertainty in Quantum Collapse Models

Models of spontaneous wavefunction collapse explain the quantum-to-classical transition without invoking the von Neumann measurement postulate. Prominent frameworks, such as the Diósi-Penrose (DP) and Continuous Spontaneous Localization (CSL) models, propose a continuous, spontaneous measurement of the mass density field of quantized matter. We show that this mechanism could link both models - not just DP - to fundamental uncertainties in Newtonian gravity. Despite their non-relativistic nature, these models suggest an induced uncertainty in the flow of time due to fluctuations in the Newtonian potential. We calculate the ultimate limit on time uncertainty and demonstrate that the resulting clock-time uncertainty remains negligible for all contemporary time-keeping devices, including atomic clocks.

quant-ph↗

Intermediate Mass Kaonic Atoms at DA$Φ$NE

The SIDDHARTA-2 collaboration aims to measure for the first time the shift and width induced on the $1s$ level of kaonic deuterium by the strong interaction. In the preliminary phase to the experiment, a test run using a Helium-4 target was performed to optimize the performance of the full experimental apparatus. This preliminary study highlighted the possibility to measure transition lines coming from intermediate mass kaonic atoms, such as kaonic carbon and kaonic aluminum. In order to measure transitions where strong interaction is manifesting at higher energies, out of the energy range of the SIDDHARTA-2 apparatus, the collaboration is testing a new detector system which exploits a novel compound semiconductor, the Cadmium Zinc Telluride. Tests are now running at DA$Φ$NE to study the performance of this detector, exploring the possibility to build a dedicated setup.

nucl-ex↗

First Linearity and Stability Characterization for CZT Detection System in a e$^+$e$^-$ Collider Environment

The SIDDHARTA-2 collaboration built a new cadmium-zinc-telluride (CZT, CdZnTe)-based X-ray detection system, used for the first time in the DA$Φ$NE electron-positron collider at INFN-LNF. The aim of this work is to show that these detectors present optimal long- and short-term linearity and stability to perform precise spectroscopic measurements in a collider environment. The spectra used as references for calibration are reported, and the results about the linearity and stability studies are presented. It is also discussed and showed what is the proper function to describe all the effects that alter the Gaussian shape in semiconductors, particularly evident in the CZT case. Good residuals and resolutions were obtained for all the calibrations. In a test run with the source and the collider beam on, it was demonstrated that the calibrations made with beam off are optimal also when the beam is on, and the actual systematics in a physics run were estimated. These promising results show the potentialities of this detector in the high rate environment of a particle collider, and pave the way for the use of CZT detectors in kaonic atoms researches and in accelerators, with applications for particle and nuclear physics.

physics.ins-det↗

Discrete symmetries tested at 10$^{-4}$ precision using linear polarization of photons from positronium annihilations

Discrete symmetries play an important role in particle physics with violation of CP connected to the matter-antimatter imbalance in the Universe. We report the most precise test of P, T and CP invariance in decays of ortho-positronium, performed with methodology involving polarization of photons from these decays. Positronium, the simplest bound state of an electron and positron, is of recent interest with discrepancies reported between measured hyperfine energy structure and theory at the level of $10^{-4}$ signaling a need for better understanding of the positronium system at this level. We test discrete symmetries using photon polarizations determined via Compton scattering in the dedicated J-PET tomograph on an event-by-event basis and without the need to control the spin of the positronium with an external magnetic field, in contrast to previous experiments. Our result is consistent with QED expectations at the level of 0.0007 and one standard deviation.

hep-ph↗

Cancellation effects as a fingerprint of quantum collapse models at atomic scale

In this work the spontaneous electromagnetic radiation from atomic systems, induced by dynamical wave-function collapse, is investigated in the X-rays domain. Strong departures are evidenced with respect to the simple cases considered until now in the literature, in which the emission is either perfectly coherent (protons in the same nuclei) or incoherent (electrons). In this low-energy regime the spontaneous radiation rate strongly depends on the atomic species under investigation and, for the first time, is found to depend on the specific collapse model.

quant-ph↗

Detecting Iron Oxidation States in Liquids with the VOXES Bragg Spectrometer

Determining the oxidation states of metals assumes great importance in various applications because a variation in the oxidation number can drastically influence the material properties. As an example, this becomes evident in edible liquids like wine and oil, where a change in the oxidation states of the contained metals can significantly modify both the overall quality and taste. To this end, here we present the MITIQO project, which aims to identify oxidation states of metals in edible liquids utilizing X-ray emission with Bragg spectroscopy. This is achieved using the VOXES crystal spectrometer, developed at INFN National Laboratories of Frascati (LNF), employing mosaic crystal (HAPG) in the Von Hamos configuration. This combination allow us to work with effective source sizes of up to a few millimeters and improves the typical low efficiency of Bragg spectroscopy, a crucial aspect when studying liquids with low metal concentration. Here we showcase the concept behind MITIQO, for a liquid solution containing oxidized iron. We performed several high-resolution emission spectra measurements, for the liquid and for different powdered samples containing oxidized and pure iron. By looking at the spectral features of the iron's K$β$ emission lineshape, we were able to obtain, for a liquid, a result consistent with the oxidized iron powders and successfully quantifying the effect of oxidation.

physics.app-ph↗

On the linear friction many-body equation for dissipative spontaneous wavefunction collapse

We construct and study the simplest universal dissipative Lindblad master equation for many-body systems with the purpose of a new dissipative extension of existing nonrelativistic theories of fundamental spontaneous decoherence and spontaneous wave function collapse in nature. It is universal as it is written in terms of second-quantized mass density $\hat ρ$ and current $\hat J$, thus making it independent of the material structure and its parameters. Assuming linear friction in the current, we find that the dissipative structure is strictly constrained. Following the general structure of our dissipative Lindblad equation, we derive and analyze the dissipative extensions of the two most known spontaneous wave function collapse models, the Diósi-Penrose and the continuous spontaneous localization models.

quant-ph↗

Comparative studies of the sensitivities of sparse and full geometries of Total-Body PET scanners built from crystals and plastic scintillators

Background: Total-Body imaging offers high sensitivity, single-bed position, and low dose, but high construction costs limit worldwide utilization. This study compares existing and developing tomographs using plastic scintillators via simulations to propose a cost-efficient Total-Body PET scanner. Methods: Simulations of eight uEXPLORER tomographs with different scintillator materials, axial field-of-view, and detector configuration, and eight J-PET scanners with various field-of-view, plastic scintillator cross-sections, and layers were performed. Biograph Vision was also simulated. Two types of simulations were conducted with a central source and a water-filled phantom. Results: BGO crystal-based scanners showed the best sensitivity (350 cps/kBq at the center). Sparse geometry or LYSO crystals reduced sensitivity. J-PET design showed similar sensitivity to sparse LYSO detectors, with full body coverage and additional gain for brain imaging. Conclusion: The J-PET tomography system using plastic scintillators could be a cost-efficient alternative for Total-Body PET scanners, overcoming high construction costs while maintaining sensitivity

physics.med-ph↗

A Time Projection Chamber to Search for Feebly Interacting Bosons via Proton Induced Nuclear Reactions

We propose a new Time Projection Chamber particle detector (TPC) to search for the existence of feebly-interacting bosons and to investigate the existence of the X17 boson, proposed by the ATOMKI group to explain anomalous results in the angular distributions of electron-positron pairs created in proton-induced nuclear reactions. Our design will provide 200 times greater sensitivity than ATOMKI and the program of research will also provide world-leading limits on feebly interacting bosons in the mass range of 5 - 25 MeV.

hep-ex↗

Experimental test of Non-Commutative Quantum Gravity by VIP-2 Lead

Pauli Exclusion Principle (PEP) violations induced by space-time non-commutativity, a class of universality for several models of Quantum Gravity, are investigated by the VIP-2 Lead experiment at the Gran Sasso underground National Laboratory of INFN. The VIP-2 Lead experimental bound on the non-commutative space-time scale $Λ$ excludes $θ$-Poincaré far above the Planck scale for non vanishing ``electric-like" components of $θ_{μν}$, and up to $6.9 \cdot 10^{-2}$ Planck scales if they are null. Therefore, this new bound represents the tightest one so far provided by atomic transitions tests. This result strongly motivates high sensitivity underground X-ray measurements as critical tests of Quantum Gravity and of the very microscopic space-time structure.

hep-th↗

First Simultaneous K$^-$p $\rightarrow (Σ^0/Λ) \, π^0$ Cross Sections Measurements at 98 MeV/c

We report the first simultaneous and independent measurements of the K$^{-}$p $\rightarrow Σ^0 \, π^{0}$ and K$^{-}$p $\rightarrow Λ\, π^{0}$ cross sections around 100 MeV/c kaon momentum. The kaon beam delivered by the DA$Φ$NE collider was exploited to detect K$^-$ absorptions on Hydrogen atoms, populating the gas mixture of the KLOE drift chamber. The precision of the measurements ($σ_{K^- p \rightarrow Σ^0 π^0} = 42.8 \pm 1.5 (stat.) ^{+2.4}_{-2.0}(syst.) \ \mathrm{mb}$ and $σ_{K^- p \rightarrow Λπ^0} = 31.0 \pm 0.5 (stat.) ^{+1.2}_{-1.2}(syst.) \ \mathrm{mb}\,$) is the highest yet obtained in the low kaon momentum regime.

nucl-ex↗

Snowmass 2021 Topical Report on Synergies in Research at Underground Facilities

This is a Snowmass 2021 Topical Report for the Underground Facilities and Infrastructure Frontier on Synergies in Research at Underground Facilities: A broad range of scientific and engineering research is possible in underground laboratories, beyond the physics-focused activities described in the other Underground Facilities and Infrastructure Topical Reports. These areas of research include nuclear astrophysics, geology, geoengineering, gravitational wave detection, biology, and perhaps soon quantum information science. This UF Topical Report will survey those other scientific and engineering research activities that share interest in research-orientated Underground Facilities and Infrastructure. In most cases the breadth and depth of research aims is too large to cover in completeness and references to surveys or key documents for those fields are provided after introductory summaries. Additional attention is then given to shared, similar, and unique needs of each research area with respect to the broader underground research community's Underground Facilities and Infrastructure needs. Where potential conflicts of usage type, site, or duration might arise, these are identified.

hep-ex↗

Strongest atomic physics bounds on Non-Commutative Quantum Gravity Models

Investigations of possible violations of the Pauli Exclusion Principle represent critical tests of the microscopic space-time structure and properties. Space-time non-commutativity provides a class of universality for several Quantum Gravity models. In this context the VIP-2 Lead experiment sets the strongest bounds, searching for Pauli Exclusion Principle violating atomic-transitions in lead, excluding the $θ$-Poincaré Non Commutative Quantum Gravity models far above the Planck scale for non-vanishing $θ_{μν}$ ``electric-like'' components, and up to $6.9 \cdot 10^{-2}$ Planck scales if $θ_{0i} = 0$.

hep-th↗

MAQRO -- BPS 2023 Research Campaign Whitepaper

The objective of the proposed MAQRO mission is to harness space for achieving long free-fall times, extreme vacuum, nano-gravity, and cryogenic temperatures to test the foundations of physics in macroscopic quantum experiments. This will result in the development of novel quantum sensors and a means to probe the foundations of quantum physics at the interface with gravity. Earlier studies showed that the proposal is feasible but that several critical challenges remain, and key technologies need to be developed. These new technologies will open up the potential for achieving additional science objectives. The proposed research campaign aims to advance the state of the art and to perform the first macroscopic quantum experiments in space. Experiments on the ground, in micro-gravity, and in space will drive the proposed research campaign during the current decade to enable the implementation of MAQRO within the subsequent decade.

quant-ph↗

Positronium imaging with the novel multiphoton PET scanner

In vivo assessment of cancer and precise location of altered tissues at initial stages of molecular disorders are important diagnostic challenges. Positronium is copiously formed in the free molecular spaces in the patient's body during positron emission tomography (PET). The positronium properties vary according to the size of inter- and intramolecular voids and the concentration of molecules in them such as, e.g., molecular oxygen, O2; therefore, positronium imaging may provide information about disease progression during the initial stages of molecular alterations. Current PET systems do not allow acquisition of positronium images. This study presents a new method that enables positronium imaging by simultaneous registration of annihilation photons and deexcitation photons from pharmaceuticals labeled with radionuclides. The first positronium imaging of a phantom built from cardiac myxoma and adipose tissue is demonstrated. It is anticipated that positronium imaging will substantially enhance the specificity of PET diagnostics.

physics.med-ph↗

Testing CPT symmetry in ortho-positronium decays with positronium annihilation tomography

Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron-positron bound state (positronium atom) motivate further investigation, including fundamental symmetry tests. While CPT noninvariance effects could be manifested in non-vanishing angular correlations between final-state photons and spin of annihilating positronium, measurements were previously limited by knowledge of the latter. Here, we demonstrate tomographic reconstruction techniques applied to three-photon annihilations of ortho-positronium atoms to estimate their spin polarisation without magnetic field or polarised positronium source. We use a plastic-scintillator-based positron-emission-tomography scanner to record ortho-positronium (o-Ps) annihilations with single-event estimation of o-Ps spin and determine the complete spectrum of an angular correlation operator sensitive to CPT-violating effects. We find no violation at the precision level of 10^{-4}, with an over threefold improvement on the previous measurement.

nucl-ex↗