Searcharxiv⌕ Search

arXiv subjects

Changqing Feng

Publications and source records attributed to Changqing Feng.

27 records · Page 2Linked to original sources

Prototype of Front-end Electronics for PandaX-4ton Experiment

At the China Jinping Underground Laboratory, the Particle AND Astrophysical Xenon phase IV (PandaX-4ton) in planning is a dark matter direct detection experiment with dual-phase xenon detector as an upgrade of the second phase of the experiment, PandaX-II. In this paper, the prototype of the front-end electronics of PandaX-4ton is presented. The front-end electronics consist of the high-gain preamplifier cards and the eight-channel digitizers with 14-bit resolution and 1 GSps sampling rate for waveform digitization. The clock synchronization circuit within the digitizer is well-designed to align all the PMT channels. The digitizer also contains gigabit fiber to exchange data with trigger and data acquisition system. The specification of effective number of bits f the digitizer is about 9.7 b at 148 MHz, and the integral nonlinearity of the digitizer ranges from -4 least significant bit (LSB) to +4 LSB, and the differential nonlinearity ranges from -0.6 LSB to +0.6 LSB. The performance of the front-end electronics can meet the requirements for the PandaX-4ton.

physics.ins-det↗

Development of a 256-channel Time-of-flight Electronics System For Neutron Beam Profiling

A 256-channel time-of-flight (TOF) electronics system has been developed for a beam line facility called "Back-n WNS" in China Spallation Neutron Source (CSNS). This paper shows the structure and performance of electronics system and the test results in CSNS. A 256-channel photomultiplier tube (PMT) is chosen as the detector in this system. In order to acquire the time information from the PMT, an electronics system has been designed. The electronics system mainly includes one front-end board (FEB), four time-to-digital converter (TDC) boards and one clock distribution module (CDM). There are 256 channels on FEB and 64 channels on each TDC board. The FEB is connected to the PMT with high-density connectors and the TDC boards are connected to the FEB through 2m cables. The TDC boards are 6U size so that they can be PCI extensions for Instrumentation (PXI) cards. Data from TDC boards can be transferred to the PXI control card through the backboard. In order to make four TDC boards work synchronously, a CDM outputs four clock signals to TDC boards which are distributed from one clock source. The TDC boards achieve a timing resolution of 3.5ns by test with a signal generator. The TOF measurement system has been used in CSNS.

physics.ins-det↗

Study on the Real-time Lossless Data Compression Method Used in the Readout System for Micro-pattern Gas Detector

The data compression technology now is fully developed and widely used in many fields such as communication, multi-media, image information processing and so on. The large physical experiments, especially the ones with Micro-pattern Gas Detectors (MPGD), which always have many readout channels and have a lot of data to be transferred and saved, are however relatively seldom use this technology. In this paper, the real-time lossless data compression method is proposed for a general-purposed MPGD readout system. The lossless data compression can reduce the data transmission bandwidth of the system as well as keep all information of the data. The compression method discussed in the paper mainly consists of two steps. The first step is to pre-process the data according to different characteristics of different signals and the second step is to compress the pre-processed data using common lossless compression algorithm. Besides, the whole compression method is implemented in the Field-Programmable Gate Array (FPGA) and able to run real-timely. The system is then used to readout two different kinds of signals and the compression rate can reach as high as 43% and 30% respectively.

physics.ins-det↗

PandaX-III: Searching for Neutrinoless Double Beta Decay with High Pressure $^{136}$Xe Gas Time Projection Chambers

Searching for the Neutrinoless Double Beta Decay (NLDBD) is now regarded as the topmost promising technique to explore the nature of neutrinos after the discovery of neutrino masses in oscillation experiments. PandaX-III (Particle And Astrophysical Xenon Experiment III) will search for the NLDBD of $^{136}$Xe at the China Jin Ping underground Laboratory (CJPL). In the first phase of the experiment, a high pressure gas Time Projection Chamber (TPC) will contain 200 kg, 90% $^{136}$Xe enriched gas operated at 10 bar. Fine pitch micro-pattern gas detector (Microbulk Micromegas) will be used at both ends of the TPC for the charge readout with a cathode in the middle. Charge signals can be used to reconstruct tracks of NLDBD events and provide good energy and spatial resolution. The detector will be immersed in a large water tank to ensure $\sim$5 m of water shielding in all directions. The second phase, a ton-scale experiment, will consist of five TPCs in the same water tank, with improved energy resolution and better control over backgrounds.

physics.ins-det↗

Temperature Dependence Calibration and Correction of the DAMPE BGO Electromagnetic Calorimeter

A BGO electromagnetic calorimeter (ECAL) is built for the DArk Matter Particle Explorer (DAMPE) mission. The effect of temperature on the BGO ECAL was investigated with a thermal vacuum experiment. The light output of a BGO crystal depends on temperature significantly. The temperature coefficient of each BGO crystal bar has been calibrated, and a correction method is also presented in this paper.

physics.ins-det↗

The calibration and electron energy reconstruction of the BGO ECAL of the DAMPE detector

The DArk Matter Particle Explorer (DAMPE) is a space experiment designed to search for dark matter indirectly by measuring the spectra of photons, electrons, and positrons up to 10 TeV. The BGO electromagnetic calorimeter (ECAL) is its main sub-detector for energy measurement. In this paper, the instrumentation and development of the BGO ECAL is briefly described. The calibration on the ground, including the pedestal, minimum ionizing particle (MIP) peak, dynode ratio, and attenuation length with the cosmic rays and beam particles is discussed in detail. Also, the energy reconstruction results of the electrons from the beam test are presented.

physics.ins-det↗

Design of the Readout Electronics for the Qualification Model of DAMPE BGO Calorimeter

The DAMPE (DArk Matter Particle Explorer) is a scientific satellite being developed in China, aimed at cosmic ray study, gamma ray astronomy, and searching for the clue of dark matter particles, with a planned mission period of more than 3 years and an orbit altitude of about 500 km. The BGO Calorimeter, which consists of 308 BGO (Bismuth Germanate Oxid) crystal bars, 616 PMTs (photomultiplier tubes) and 1848 dynode signals, has approximately 32 radiation lengths. It is a crucial sub-detector of the DAMPE payload, with the functions of precisely measuring the energy of cosmic particles from 5 GeV to 10TeV, distinguishing positrons/electrons and gamma rays from hadron background, and providing trigger information for the whole DAMPE payload. The dynamic range for a single BGO crystal is about 2?105 and there are 1848 detector signals in total. To build such an instrument in space, the major design challenges for the readout electronics come from the large dynamic range, the high integrity inside the very compact structure, the strict power supply budget and the long term reliability to survive the hush environment during launch and in orbit. Currently the DAMPE mission is in the end of QM (Qualification Model) stage. This paper presents a detailed description of the readout electronics for the BGO calorimeter.

astro-ph.IM↗

Study on FPGA SEU Mitigation for Readout Electronics of DAMPE BGO Calorimeter

The BGO calorimeter, which provides a wide measurement range of the primary cosmic ray spectrum, is a key sub-detector of Dark Matter Particle Explorer (DAMPE). The readout electronics of calorimeter consists of 16 pieces of Actel ProASIC Plus FLASH-based FPGA, of which the design-level flip-flops and embedded block RAMs are single event upset (SEU) sensitive in the harsh space environment. Therefore to comply with radiation hardness assurance (RHA), SEU mitigation methods, including partial triple modular redundancy (TMR), CRC checksum, and multi-domain reset are analyzed and tested by the heavy-ion beam test. Composed of multi-level redundancy, a FPGA design with the characteristics of SEU tolerance and low resource consumption is implemented for the readout electronics.

physics.ins-det↗

A new method of waveform digitization based on time-interleaved A/D conversion

Time interleaved analog-to-digital conversion (TIADC) based on parallelism is an effective way to meet the requirement of the ultra-fast waveform digitizer beyond Gsps. Different methods to correct the mismatch errors among different analog-to-digital conversion channels have been developed previously. To overcome the speed limitation in hardware design and to implement the mismatch correction algorithm in real time, this paper proposes a fully parallel correction algorithm. A 12-bit 1-Gsps waveform digitizer with ENOB around 10.5 bit from 5 MHz to 200 MHz is implemented based on the real-time correction algorithm.

physics.ins-det↗