SearcharxivSearch

arXiv subjects

Chien-Chun Chen

Publications and source records attributed to Chien-Chun Chen.

15 recordsLinked to original sources

Circular Phase Representation and Geometry-Aware Optimization for Ptychographic Image Reconstruction

Traditional iterative reconstruction methods are accurate but computationally expensive, limiting their use in high-throughput and real-time ptychography. Recent deep learning approaches improve speed, but often predict phase as a Euclidean scalar despite its $2\pi$ periodicity, which can introduce wrapping artifacts, discontinuities at $\pm\pi$, and a mismatch between the loss and the underlying signal geometry. We present a deep learning framework for ptychographic reconstruction that models phase on the unit circle using cosine and sine components. Phase error is optimized with a differentiable geodesic loss, which avoids branch-cut discontinuities and provides bounded gradients. The network further incorporates saturation-aware dual-gain input scaling, parallel encoder branches, and three decoders for amplitude, cosine, and sine prediction, together with a composite loss that promotes circular consistency and structural fidelity. Experiments on synthetic and experimental datasets show consistent improvements in both amplitude and phase reconstruction over existing deep learning methods. Frequency-domain analysis further shows better preservation of mid- and high-frequency phase content. The proposed method also provides substantial speedup over iterative solvers while maintaining physically consistent reconstructions.

eess.IV

A Physics-Inspired Deep Learning Framework with Polar Coordinate Attention for Ptychographic Imaging

Ptychographic imaging confronts inherent challenges in applying deep learning for phase retrieval from diffraction patterns. Conventional neural architectures, both convolutional neural networks and Transformer-based methods, are optimized for natural images with Euclidean spatial neighborhood-based inductive biases that exhibit geometric mismatch with the concentric coherent patterns characteristic of diffraction data in reciprocal space. In this paper, we present PPN, a physics-inspired deep learning network with Polar Coordinate Attention (PoCA) for ptychographic imaging, that aligns neural inductive biases with diffraction physics through a dual-branch architecture separating local feature extraction from non-local coherence modeling. It consists of a PoCA mechanism that replaces Euclidean spatial priors with physically consistent radial-angular correlations. PPN outperforms existing end-to-end models, with spectral and spatial analysis confirming its greater preservation of high-frequency details. Notably, PPN maintains robust performance compared to iterative methods even at low overlap ratios, making it well suited for high-throughput imaging in real-world acquisition scenarios for samples with consistent structural characteristics.

physics.optics

Observation of Mesoscopic Clathrate Structures in Ethanol-Water Mixtures

Water-alcohol mixtures exhibit many abnormal physicochemical properties, the origins of which remain controversial. Here we use transmission electron microscopy (TEM), nanoparticle tracking analysis (NTA), and atomic force microscopy (AFM) to study ethanol-water mixtures. TEM reveals mesoscopic clathrate structures with water molecules forming a crystalline matrix hosting a high density of tiny cells. The presence of these mesoscopic clathrate structures is further supported by a refractive index of 1.27+-0.02 at 405 nm measured via NTA and the hydrophilic nature of the mesoscopic structures implied by AFM observations, explaining many long-standing puzzles related to water-alcohol mixtures.

cond-mat.mes-hall

Deciphering chemical order/disorder and material properties at the single-atom level

Correlating 3D arrangements of atoms and defects with material properties and functionality forms the core of several scientific disciplines. Here, we determined the 3D coordinates of 6,569 iron and 16,627 platinum atoms in a model iron-platinum nanoparticle system to correlate 3D atomic arrangements and chemical order/disorder with material properties at the single-atom level. We identified rich structural variety and chemical order/disorder including 3D atomic composition, grain boundaries, anti-phase boundaries, anti-site point defects and swap defects. We show for the first time that experimentally measured 3D atomic coordinates and chemical species with 22 pm precision can be used as direct input for first-principles calculations of material properties such as atomic magnetic moments and local magnetocrystalline anisotropy. This work not only opens the door to determining 3D atomic arrangements and chemical order/disorder of a wide range of nanostructured materials with high precision, but also will transform our understanding of structure-property relationships at the most fundamental level.

cond-mat.mtrl-sci

Nanomaterial datasets to advance tomography in scanning transmission electron microscopy

Electron tomography in materials science has flourished with the demand to characterize nanoscale materials in three dimensions (3D). Access to experimental data is vital for developing and validating reconstruction methods that improve resolution and reduce radiation dose requirements. This work presents five high-quality scanning transmission electron microscope (STEM) tomography datasets in order to address the critical need for open access data in this field. The datasets represent the current limits of experimental technique, are of high quality, and contain materials with structural complexity. Included are tomographic series of a hyperbranched Co2P nanocrystal, platinum nanoparticles on a carbon nanofibre imaged over the complete 180° tilt range, a platinum nanoparticle and a tungsten needle both imaged at atomic resolution by equal slope tomography, and a through-focal tilt series of PtCu nanoparticles. A volumetric reconstruction from every dataset is provided for comparison and development of post-processing and visualization techniques. Researchers interested in creating novel data processing and reconstruction algorithms will now have access to state of the art experimental test data.

cond-mat.mes-hall

Three-dimensional coordinates of individual atoms in materials revealed by electron tomography

Crystallography, the primary method for determining the three-dimensional (3D) atomic positions in crystals, has been fundamental to the development of many fields of science. However, the atomic positions obtained from crystallography represent a global average of many unit cells in a crystal. Here, we report, for the first time, the determination of the 3D coordinates of thousands of individual atoms and a point defect in a material by electron tomography with a precision of ~19 picometers, where the crystallinity of the material is not assumed. From the coordinates of these individual atoms, we measure the atomic displacement field and the full strain tensor with a 3D resolution of ~1nm^3 and a precision of ~10^-3, which are further verified by density functional theory calculations and molecular dynamics simulations. The ability to precisely localize the 3D coordinates of individual atoms in materials without assuming crystallinity is expected to find important applications in materials science, nanoscience, physics and chemistry.

cond-mat.mtrl-sci

Reply to "Local Filtering Fundamentally Against Wide Spectrum"

After carefully studying the comment by Wang et al. (arXiv:1408.6420), we found it includes several mistakes and unjustified statements and Wang et al. lack very basic knowledge of dislocations. Moreover, there is clear evidence indicating that Wang et al. significantly misrepresented our method and claimed something that they actually did not implement.

physics.data-an

Three-dimensional coherent X-ray diffraction imaging of a whole, frozen-hydrated cell

A structural understanding of whole cells in three dimensions at high spatial resolution remains a significant challenge and, in the case of X-rays, has been limited by radiation damage. By alleviating this limitation, cryogenic coherent diffraction imaging (cryo-CDI) could bridge the important resolution gap between optical and electron microscopy in bio-imaging. Here, we report for the first time 3D cryo-CDI of a whole, frozen-hydrated cell - in this case a Neospora caninum tachyzoite - using 8 keV X-rays. Our 3D reconstruction reveals the surface and internal morphology of the cell, including its complex, polarized sub-cellular architecture with a 3D resolution of ~75-100 nm, which is presently limited by the coherent X-ray flux and detector size. Given the imminent improvement in the coherent X-ray flux at the facilities worldwide, our work forecasts the possibility of routine 3D imaging of frozen-hydrated cells with spatial resolutions in the tens of nanometres.

physics.bio-ph

Multi-Shell Ankylography

Three-dimensional (3D) imaging techniques appeal to a broad range of scientific and industrial applications. Typically, projection slice theorem enables multiple two-dimensional (2D) projections of an object to be combined in the Fourier domain to yield a 3D image. However, traditional techniques require a significant number of projections. The significant number of views required in conventional tomography not only complicates such imaging modalities, but also limits their ability to image samples that are sensitive to radiation dose or are otherwise unstable in time. In this work, we demonstrate through numerical simulations and an eigenvalue analysis that a recently developed technique called ankylography enables 3D image reconstruction using much fewer views than conventional tomography. Such a technique with the ability to obtain the 3D structure information from a few views is expected to find applications in both optical and x-ray imaging fields.

physics.optics

Single-shot 3D structure determination of nanocrystals with femtosecond X-ray free electron laser pulses

Coherent diffraction imaging (CDI) using synchrotron radiation, X-ray free electron lasers (X-FELs), high harmonic generation, soft X-ray lasers, and optical lasers has found broad applications across several disciplines. An active research direction in CDI is to determine the structure of single particles with intense, femtosecond X-FEL pulses based on diffraction-before-destruction scheme. However, single-shot 3D structure determination has not been experimentally realized yet. Here we report the first experimental demonstration of single-shot 3D structure determination of individual nanocrystals using ~10 femtosecond X-FEL pulses. Coherent diffraction patterns are collected from high-index-faceted nanocrystals, each struck by a single X-FEL pulse. Taking advantage of the symmetry of the nanocrystal, we reconstruct the 3D structure of each nanocrystal from a single-shot diffraction pattern at ~5.5 nm resolution. As symmetry exists in many nanocrystals and virus particles, this method can be applied to 3D structure studies of such particles at nanometer resolution on femtosecond time scales.

physics.optics

Oversampling smoothness (OSS): an effective algorithm for phase retrieval of noisy diffraction intensities

Coherent diffraction imaging (CDI) is high-resolution lensless microscopy that has been applied to image a wide range of specimens using synchrotron radiation, X-ray free electron lasers, high harmonic generation, soft X-ray laser and electrons. Despite these rapid advances, it remains a challenge to reconstruct fine features in weakly scattering objects such as biological specimens from noisy data. Here we present an effective iterative algorithm, termed oversampling smoothness (OSS), for phase retrieval of noisy diffraction intensities. OSS exploits the correlation information among the pixels or voxels in the region outside of a support in real space. By properly applying spatial frequency filters to the pixels or voxels outside the support at different stage of the iterative process (i.e. a smoothness constraint), OSS finds a balance between the hybrid input-output (HIO) and error reduction (ER) algorithms to search for a global minimum in solution space, while reducing the oscillations in the reconstruction. Both our numerical simulations with Poisson noise and experimental data from a biological cell indicate that OSS consistently outperforms the HIO, ER-HIO and noise robust (NR)-HIO algorithms at all noise levels in terms of accuracy and consistency of the reconstructions. We expect OSS to find application in the rapidly growing CDI field as well as other disciplines where phase retrieval from noisy Fourier magnitudes is needed.

physics.optics

Electron tomography at 2.4 Å resolution

Transmission electron microscopy (TEM) is a powerful imaging tool that has found broad application in materials science, nanoscience and biology(1-3). With the introduction of aberration-corrected electron lenses, both the spatial resolution and image quality in TEM have been significantly improved(4,5) and resolution below 0.5 Å has been demonstrated(6). To reveal the 3D structure of thin samples, electron tomography is the method of choice(7-11), with resolutions of ~1 nm^3 currently achievable(10,11). Recently, discrete tomography has been used to generate a 3D atomic reconstruction of a silver nanoparticle 2-3 nm in diameter(12), but this statistical method assumes prior knowledge of the particle's lattice structure and requires that the atoms fit rigidly on that lattice. Here we report the experimental demonstration of a general electron tomography method that achieves atomic scale resolution without initial assumptions about the sample structure. By combining a novel projection alignment and tomographic reconstruction method with scanning transmission electron microscopy, we have determined the 3D structure of a ~10 nm gold nanoparticle at 2.4 Å resolution. While we cannot definitively locate all of the atoms inside the nanoparticle, individual atoms are observed in some regions of the particle and several grains are identified at three dimensions. The 3D surface morphology and internal lattice structure revealed are consistent with a distorted icosahedral multiply-twinned particle. We anticipate that this general method can be applied not only to determine the 3D structure of nanomaterials at atomic scale resolution(13-15), but also to improve the spatial resolution and image quality in other tomography fields(7,9,16-20).

cond-mat.mtrl-sci

Potential and Challenge of Ankylography

The concept of ankylography, which under certain circumstances enables 3D structure determination from a single view [1], had ignited a lively debate even before its publication [2,3]. Since then, a number of readers requested the ankylographic reconstruction codes from us. To facilitate a better understanding of ankylography, we posted the source codes of the ankylographic reconstruction on a public website and encouraged interested readers to download the codes and test the method [4]. Those who have tested our codes confirm that the principle of ankylography works. Furthermore, our mathematical analysis and numerical simulations suggest that, for a continuous object with array size of 14x14x14 voxels, its 3D structure can usually be reconstructed from the diffraction intensities sampled on a spherical shell of 1 voxel thick [4]. In some cases where the object does not have very dense structure, ankylography can be applied to reconstruct its 3D image with array size of 25x25x25 voxels [4]. What remains to be elucidated is how to extend ankylography to the reconstruction of larger objects, and what further theoretical, experimental and algorithm developments will be necessary to make ankylography a practical and useful imaging tool. Here we present our up-to-date understanding of the potential and challenge of ankylography. Further, we clarify some misconceptions on ankylography, and respond to technical comments raised by Wei [5] and Wang et al. [6] Finally, it is worthwhile to point out that the potential for recovering 3D information from the Fourier coefficients within a spherical shell may also find application in other fields.

physics.optics

3D Imaging of a Phase Object from a Single Sample Orientation Using an Optical Laser

Ankylography is a new 3D imaging technique, which, under certain circumstances, enables reconstruction of a 3D object from a single sample orientation. Here, we provide a matrix rank analysis to explain the principle of ankylography. We then present an ankylography experiment on a microscale phase object using an optical laser. Coherent diffraction patterns are acquired from the phase object using a planar CCD detector and are projected onto a spherical shell. The 3D structure of the object is directly reconstructed from the spherical diffraction pattern. This work may potentially open the door to a new method for 3D imaging of phase objects in the visible light region. Finally, the extension of ankylography to more complicated and larger objects is suggested.

physics.optics

2nd Response to "Feasibility of 3D reconstruction from a single 2D diffraction measurement"

We present our 2nd response to Thibault's commentary article [1] and his reply [2], in which he commented upon our ankylography paper [3] and our 1st response [4]. In this article, we further explain why we think Thibault's theoretical analysis is flawed and his interpretation of our experiment is incorrect. Furthermore, we provide a quantitative analysis and a numerical experiment to illustrate why ankylography can in principle be applicable to general samples. Finally, we present detailed procedures for our numerical experiment on ankylographic reconstructions, which uses the traditional HIO algorithm only with the positivity constraint [5]. We welcome anyone (including Thibault) interested in ankylography to perform numerical experiments and verify our results. We will be very happy to provide any help if needed.

physics.optics