Searcharxiv⌕ Search

arXiv subjects

Chin-Tu Chen

Publications and source records attributed to Chin-Tu Chen.

4 recordsLinked to original sources

Characterization of a Large-Area HRPPD MCP-PMT Coupled to LYSO for TOF-PET

Large-area microchannel-plate photomultipliers (MCP-PMTs) such as the High-Rate Picosecond Photon Detector (HRPPD) are attractive for time-of-flight positron emission tomography (TOF-PET). They offer excellent single-photon time resolution, low dark count rate, and large monolithic active areas. However, the coincidence time resolution (CTR) reported so far with PET scintillators falls short of expectations based upon their single-photon time resolution. We characterized a 104x104 mm$^2$ HRPPD coupled to LYSO crystals and read out through a custom high-frequency amplifier. With a 2x2x3 mm$^3$ LYSO crystal we measured a CTR of 107 ps full width at half maximum (FWHM) against a silicon photomultiplier (SiPM)-based reference detector. After subtracting the calibrated reference detector's contribution of 42 ps, the single HRPPD detector was found to contribute 98 ps, corresponding to 139 ps for two identical HRPPD detectors in coincidence. With clinical 3x3x20 mm$^3$ crystals the CTR against the reference SiPM detector was 160 ps, corresponding to 218 ps for two identical HRPPD detectors. Timing and gain were uniform across output pads within measurement precision. Summing the four pads under a 3x3x10 mm$^3$ LYSO crystal, the energy resolution for 511 keV gamma ray was 14.6% FWHM, and the 1275 keV line of the $^{22}$Na source was within 1% of its proportional position relative to the 511 keV peak. Flood maps resolved the individual 3 mm elements of a 4x4 array despite the 25 mm pad pitch. To the best of our knowledge the observed timing resolution improves substantially on what has been reported for large-area MCP-PMTs coupled to PET scintillators, and the crystal array identification has not been demonstrated before on such a device. These results indicate that this device class deserves renewed consideration as a photodetector technology for high-performance TOF-PET systems.

physics.ins-det↗

An analytic, moment-based method to estimate orthopositronium lifetimes in positron annihilation lifetime spectroscopy measurements

The presence of tumor hypoxia is known to correlate with poor patient prognosis. Measurement of tissue oxygen concentration can be challenging, but recent advancements using positron annihilation lifetime spectroscopy (PALS) in three-dimensional positron emission tomography (PET) scans have shown promise for hypoxia detection. In this work, a novel method for estimating the orthopositronium lifetime in PALS is presented. This method is analytical and uses moments of the time-difference histogram from photon arrival times. For sufficient statistical power, the method produces monotonic, stable estimates. For cases with a lower number of photon counts, the method was characterized and solutions are presented to correct for bias and estimation variability.

physics.med-ph↗

Development of a PET/EPRI combined imaging system for assessing tumor hypoxia

Precise quantitative delineation of tumor hypoxia is essential in radiation therapy treatment planning to improve the treatment efficacy by targeting hypoxic sub-volumes. We developed a combined imaging system of positron emission tomography (PET) and electron para-magnetic resonance imaging (EPRI) of molecular oxygen to investigate the accuracy of PET imaging in assessing tumor hypoxia. The PET/EPRI combined imaging system aims to use EPRI to precisely measure the oxygen partial pressure in tissues. This will evaluate the validity of PET hypoxic tumor imaging by (near) simultaneously acquired EPRI as ground truth. The combined imaging system was constructed by integrating a small animal PET scanner (inner ring diameter 62 mm and axial field of view 25.6 mm) and an EPRI subsystem (field strength 25 mT and resonant frequency 700 MHz). The compatibility between the PET and EPRI subsystems were tested with both phantom and animal imaging. Hypoxic imaging on a tumor mouse model using $^{18}$F-fluoromisonidazole radio-tracer was conducted with the developed PET/EPRI system. We report the development and initial imaging results obtained from the PET/EPRI combined imaging system.

physics.med-ph↗

Dynamic and programmable cellular-scale granules enable tissue-like materials

Tissue-like materials are required in many robotic systems to improve human-machine interactions. However, the mechanical properties of living tissues are difficult to replicate. Synthetic materials are not usually capable of simultaneously displaying the behaviors of the cellular ensemble and the extracellular matrix. A particular challenge is identification of a cell-like synthetic component which is tightly integrated with its matrix and also responsive to external stimuli at the population level. Here, we demonstrate that cellular-scale hydrated starch granules, an underexplored component in materials science, can turn conventional hydrogels into tissue-like materials when composites are formed. Using several synchrotron-based X-ray techniques, we reveal the mechanically-induced motion and training dynamics of the starch granules in the hydrogel matrix. These dynamic behaviors enable multiple tissue-like properties such as strain-stiffening, anisotropy, mechanical heterogeneity, programmability, mechanochemistry, impact absorption, and self-healability. The starch-hydrogel composites can be processed as robotic skins that maintain these tissue-like characteristics.

cond-mat.soft↗