Searcharxiv⌕ Search

arXiv subjects

Christian Holz

Publications and source records attributed to Christian Holz.

At least 37 records · Page 2Linked to original sources

Group Inertial Poser: Multi-Person Pose and Global Translation from Sparse Inertial Sensors and Ultra-Wideband Ranging

Tracking human full-body motion using sparse wearable inertial measurement units (IMUs) overcomes the limitations of occlusion and instrumentation of the environment inherent in vision-based approaches. However, purely IMU-based tracking compromises translation estimates and accurate relative positioning between individuals, as inertial cues are inherently self-referential and provide no direct spatial reference for others. In this paper, we present a novel approach for robustly estimating body poses and global translation for multiple individuals by leveraging the distances between sparse wearable sensors - both on each individual and across multiple individuals. Our method Group Inertial Poser estimates these absolute distances between pairs of sensors from ultra-wideband ranging (UWB) and fuses them with inertial observations as input into structured state-space models to integrate temporal motion patterns for precise 3D pose estimation. Our novel two-step optimization further leverages the estimated distances for accurately tracking people's global trajectories through the world. We also introduce GIP-DB, the first IMU+UWB dataset for two-person tracking, which comprises 200 minutes of motion recordings from 14 participants. In our evaluation, Group Inertial Poser outperforms previous state-of-the-art methods in accuracy and robustness across synthetic and real-world data, showing the promise of IMU+UWB-based multi-human motion capture in the wild. Code, models, dataset: https://github.com/eth-siplab/GroupInertialPoser

cs.CV↗

Preference-Guided Multi-Objective UI Adaptation

3D Mixed Reality interfaces have nearly unlimited space for layout placement, making automatic UI adaptation crucial for enhancing the user experience. Such adaptation is often formulated as a multi-objective optimization (MOO) problem, where multiple, potentially conflicting design objectives must be balanced. However, selecting a final layout is challenging since MOO typically yields a set of trade-offs along a Pareto frontier. Prior approaches often required users to manually explore and evaluate these trade-offs, a time-consuming process that disrupts the fluidity of interaction. To eliminate this manual and laborous step, we propose a novel optimization approach that efficiently determines user preferences from a minimal number of UI element adjustments. These determined rankings are translated into priority levels, which then drive our priority-based MOO algorithm. By focusing the search on user-preferred solutions, our method not only identifies UIs that are more aligned with user preferences, but also automatically selects the final design from the Pareto frontier; ultimately, it minimizes user effort while ensuring personalized layouts. Our user study in a Mixed Reality setting demonstrates that our preference-guided approach significantly reduces manual adjustments compared to traditional methods, including fully manual design and exhaustive Pareto front searches, while maintaining high user satisfaction. We believe this work opens the door for more efficient MOO by seamlessly incorporating user preferences.

cs.HC↗

Human Motion Capture from Loose and Sparse Inertial Sensors with Garment-aware Diffusion Models

Motion capture using sparse inertial sensors has shown great promise due to its portability and lack of occlusion issues compared to camera-based tracking. Existing approaches typically assume that IMU sensors are tightly attached to the human body. However, this assumption often does not hold in real-world scenarios. In this paper, we present Garment Inertial Poser (GaIP), a method for estimating full-body poses from sparse and loosely attached IMU sensors. We first simulate IMU recordings using an existing garment-aware human motion dataset. Our transformer-based diffusion models synthesize loose IMU data and estimate human poses from this challenging loose IMU data. We also demonstrate that incorporating garment-related parameters during training on loose IMU data effectively maintains expressiveness and enhances the ability to capture variations introduced by looser or tighter garments. Our experiments show that our diffusion methods trained on simulated and synthetic data outperform state-of-the-art inertial full-body pose estimators, both quantitatively and qualitatively, opening up a promising direction for future research on motion capture from such realistic sensor placements.

cs.GR↗

Efficient Visual Appearance Optimization by Learning from Prior Preferences

Adjusting visual parameters such as brightness and contrast is common in our everyday experiences. Finding the optimal parameter setting is challenging due to the large search space and the lack of an explicit objective function, leaving users to rely solely on their implicit preferences. Prior work has explored Preferential Bayesian Optimization (PBO) to address this challenge, involving users to iteratively select preferred designs from candidate sets. However, PBO often requires many rounds of preference comparisons, making it more suitable for designers than everyday end-users. We propose Meta-PO, a novel method that integrates PBO with meta-learning to improve sample efficiency. Specifically, Meta-PO infers prior users' preferences and stores them as models, which are leveraged to intelligently suggest design candidates for the new users, enabling faster convergence and more personalized results. An experimental evaluation of our method for appearance design tasks on 2D and 3D content showed that participants achieved satisfactory appearance in 5.86 iterations using Meta-PO when participants shared similar goals with a population (e.g., tuning for a ``warm'' look) and in 8 iterations even generalizes across divergent goals (e.g., from ``vintage'', ``warm'', to ``holiday''). Meta-PO makes personalized visual optimization more applicable to end-users through a generalizable, more efficient optimization conditioned on preferences, with the potential to scale interface personalization more broadly.

cs.HC↗

egoPPG: Heart Rate Estimation from Eye-Tracking Cameras in Egocentric Systems to Benefit Downstream Vision Tasks

Egocentric vision systems aim to understand the spatial surroundings and the wearer's behavior inside it, including motions, activities, and interactions. We argue that egocentric systems must additionally detect physiological states to capture a person's attention and situational responses, which are critical for context-aware behavior modeling. In this paper, we propose egoPPG, a novel vision task for egocentric systems to recover a person's cardiac activity to aid downstream vision tasks. We introduce PulseFormer, a method to extract heart rate as a key indicator of physiological state from the eye tracking cameras on unmodified egocentric vision systems. PulseFormer continuously estimates the photoplethysmogram (PPG) from areas around the eyes and fuses motion cues from the headset's inertial measurement unit to track HR values. We demonstrate egoPPG's downstream benefit for a key task on EgoExo4D, an existing egocentric dataset for which we find PulseFormer's estimates of HR to improve proficiency estimation by 14%. To train and validate PulseFormer, we collected a dataset of 13+ hours of eye tracking videos from Project Aria and contact-based PPG signals as well as an electrocardiogram (ECG) for ground-truth HR values. Similar to EgoExo4D, 25 participants performed diverse everyday activities such as office work, cooking, dancing, and exercising, which induced significant natural motion and HR variation (44-164 bpm). Our model robustly estimates HR (MAE=7.67 bpm) and captures patterns (r=0.85). Our results show how egocentric systems may unify environmental and physiological tracking to better understand users and that egoPPG as a complementary task provides meaningful augmentations for existing datasets and tasks. We release our code, dataset, and HR augmentations for EgoExo4D to inspire research on physiology-aware egocentric tasks.

cs.CV↗

Beyond Subjectivity: Continuous Cybersickness Detection Using EEG-based Multitaper Spectrum Estimation

Virtual reality (VR) presents immersive opportunities across many applications, yet the inherent risk of developing cybersickness during interaction can severely reduce enjoyment and platform adoption. Cybersickness is marked by symptoms such as dizziness and nausea, which previous work primarily assessed via subjective post-immersion questionnaires and motion-restricted controlled setups. In this paper, we investigate the \emph{dynamic nature} of cybersickness while users experience and freely interact in VR. We propose a novel method to \emph{continuously} identify and quantitatively gauge cybersickness levels from users' \emph{passively monitored} electroencephalography (EEG) and head motion signals. Our method estimates multitaper spectrums from EEG, integrating specialized EEG processing techniques to counter motion artifacts, and, thus, tracks cybersickness levels in real-time. Unlike previous approaches, our method requires no user-specific calibration or personalization for detecting cybersickness. Our work addresses the considerable challenge of reproducibility and subjectivity in cybersickness research.

cs.HC↗

Exploring LLM Agents for Cleaning Tabular Machine Learning Datasets

High-quality, error-free datasets are a key ingredient in building reliable, accurate, and unbiased machine learning (ML) models. However, real world datasets often suffer from errors due to sensor malfunctions, data entry mistakes, or improper data integration across multiple sources that can severely degrade model performance. Detecting and correcting these issues typically require tailor-made solutions and demand extensive domain expertise. Consequently, automation is challenging, rendering the process labor-intensive and tedious. In this study, we investigate whether Large Language Models (LLMs) can help alleviate the burden of manual data cleaning. We set up an experiment in which an LLM, paired with Python, is tasked with cleaning the training dataset to improve the performance of a learning algorithm without having the ability to modify the training pipeline or perform any feature engineering. We run this experiment on multiple Kaggle datasets that have been intentionally corrupted with errors. Our results show that LLMs can identify and correct erroneous entries, such as illogical values or outlier, by leveraging contextual information from other features within the same row, as well as feedback from previous iterations. However, they struggle to detect more complex errors that require understanding data distribution across multiple rows, such as trends and biases.

cs.LG↗

Continual Human-in-the-Loop Optimization

Optimal input settings vary across users due to differences in motor abilities and personal preferences, which are typically addressed by manual tuning or calibration. Although human-in-the-loop optimization has the potential to identify optimal settings during use, it is rarely applied due to its long optimization process. A more efficient approach would continually leverage data from previous users to accelerate optimization, exploiting shared traits while adapting to individual characteristics. We introduce the concept of Continual Human-in-the-Loop Optimization and a Bayesian optimization-based method that leverages a Bayesian-neural-network surrogate model to capture population-level characteristics while adapting to new users. We propose a generative replay strategy to mitigate catastrophic forgetting. We demonstrate our method by optimizing virtual reality keyboard parameters for text entry using direct touch, showing reduced adaptation times with a growing user base. Our method opens the door for next-generation personalized input systems that improve with accumulated experience.

cs.HC↗

Shifting the Paradigm: A Diffeomorphism Between Time Series Data Manifolds for Achieving Shift-Invariancy in Deep Learning

Deep learning models lack shift invariance, making them sensitive to input shifts that cause changes in output. While recent techniques seek to address this for images, our findings show that these approaches fail to provide shift-invariance in time series, where the data generation mechanism is more challenging due to the interaction of low and high frequencies. Worse, they also decrease performance across several tasks. In this paper, we propose a novel differentiable bijective function that maps samples from their high-dimensional data manifold to another manifold of the same dimension, without any dimensional reduction. Our approach guarantees that samples -- when subjected to random shifts -- are mapped to a unique point in the manifold while preserving all task-relevant information without loss. We theoretically and empirically demonstrate that the proposed transformation guarantees shift-invariance in deep learning models without imposing any limits to the shift. Our experiments on six time series tasks with state-of-the-art methods show that our approach consistently improves the performance while enabling models to achieve complete shift-invariance without modifying or imposing restrictions on the model's topology. The source code is available on \href{https://github.com/eth-siplab/Shifting-the-Paradigm}{GitHub}.

cs.LG↗

EgoSim: An Egocentric Multi-view Simulator and Real Dataset for Body-worn Cameras during Motion and Activity

Research on egocentric tasks in computer vision has mostly focused on head-mounted cameras, such as fisheye cameras or embedded cameras inside immersive headsets. We argue that the increasing miniaturization of optical sensors will lead to the prolific integration of cameras into many more body-worn devices at various locations. This will bring fresh perspectives to established tasks in computer vision and benefit key areas such as human motion tracking, body pose estimation, or action recognition -- particularly for the lower body, which is typically occluded. In this paper, we introduce EgoSim, a novel simulator of body-worn cameras that generates realistic egocentric renderings from multiple perspectives across a wearer's body. A key feature of EgoSim is its use of real motion capture data to render motion artifacts, which are especially noticeable with arm- or leg-worn cameras. In addition, we introduce MultiEgoView, a dataset of egocentric footage from six body-worn cameras and ground-truth full-body 3D poses during several activities: 119 hours of data are derived from AMASS motion sequences in four high-fidelity virtual environments, which we augment with 5 hours of real-world motion data from 13 participants using six GoPro cameras and 3D body pose references from an Xsens motion capture suit. We demonstrate EgoSim's effectiveness by training an end-to-end video-only 3D pose estimation network. Analyzing its domain gap, we show that our dataset and simulator substantially aid training for inference on real-world data. EgoSim code & MultiEgoView dataset: https://siplab.org/projects/EgoSim

cs.CV↗

BMAR: Barometric and Motion-based Alignment and Refinement for Offline Signal Synchronization across Devices

A requirement of cross-modal signal processing is accurate signal alignment. Though simple on a single device, accurate signal synchronization becomes challenging as soon as multiple devices are involved, such as during activity monitoring, health tracking, or motion capture - particularly outside controlled scenarios where data collection must be standalone, low-power, and support long runtimes. In this paper, we present BMAR, a novel synchronization method that operates purely based on recorded signals and is thus suitable for offline processing. BMAR needs no wireless communication between devices during runtime and does not require any specific user input, action, or behavior. BMAR operates on the data from devices worn by the same person that record barometric pressure and acceleration - inexpensive, low-power, and thus commonly included sensors in today's wearable devices. In its first stage, BMAR verifies that two recordings were acquired simultaneously and pre-aligns all data traces. In a second stage, BMAR refines the alignment using acceleration measurements while accounting for clock skew between devices. In our evaluation, three to five body-worn devices recorded signals from the wearer for up to ten hours during a series of activities. BMAR synchronized all signal recordings with a median error of 33.4 ms and reliably rejected non-overlapping signal traces. The worst-case activity was sleeping, where BMAR's second stage could not exploit motion for refinement and, thus, aligned traces with a median error of 3.06 s.

eess.SP↗

Redefining Affordance via Computational Rationality

Affordances, a foundational concept in human-computer interaction and design, have traditionally been explained by direct-perception theories, which assume that individuals perceive action possibilities directly from the environment. However, these theories fall short of explaining how affordances are perceived, learned, refined, or misperceived, and how users choose between multiple affordances in dynamic contexts. This paper introduces a novel affordance theory grounded in Computational Rationality, positing that humans construct internal representations of the world based on bounded sensory inputs. Within these internal models, affordances are inferred through two core mechanisms: feature recognition and hypothetical motion trajectories. Our theory redefines affordance perception as a decision-making process, driven by two components: confidence (the perceived likelihood of successfully executing an action) and predicted utility (the expected value of the outcome). By balancing these factors, individuals make informed decisions about which actions to take. Our theory frames affordances perception as dynamic, continuously learned, and refined through reinforcement and feedback. We validate the theory via thought experiments and demonstrate its applicability across diverse types of affordances (e.g., physical, digital, social). Beyond clarifying and generalizing the understanding of affordances across contexts, our theory serves as a foundation for improving design communication and guiding the development of more adaptive and intuitive systems that evolve with user capabilities.

cs.HC↗

Robust Heart Rate Detection via Multi-Site Photoplethysmography

Smartwatches have become popular for monitoring physiological parameters outside clinical settings. Using reflective photoplethysmography (PPG) sensors, such watches can non-invasively estimate heart rate (HR) in everyday environments and throughout a patient's day. However, achieving consistently high accuracy remains challenging, particularly during moments of increased motion or due to varying device placement. In this paper, we introduce a novel sensor fusion method for estimating HR that flexibly combines samples from multiple PPG sensors placed across the patient's body, including wrist, ankle, head, and sternum (chest). Our method first estimates signal quality across all inputs to dynamically integrate them into a joint and robust PPG signal for HR estimation. We evaluate our method on a novel dataset of PPG and ECG recordings from 14 participants who engaged in real-world activities outside the laboratory over the course of a whole day. Our method achieves a mean HR error of 2.4\,bpm, which is 46\% lower than the mean error of the best-performing single device (4.4\,bpm, head).

eess.SP↗

WildPPG: A Real-World PPG Dataset of Long Continuous Recordings

Reflective photoplethysmography (PPG) has become the default sensing technique in wearable devices to monitor cardiac activity via a person's heart rate (HR). However, PPG-based HR estimates can be substantially impacted by factors such as the wearer's activities, sensor placement and resulting motion artifacts, as well as environmental characteristics such as temperature and ambient light. These and other factors can significantly impact and decrease HR prediction reliability. In this paper, we show that state-of-the-art HR estimation methods struggle when processing \emph{representative} data from everyday activities in outdoor environments, likely because they rely on existing datasets that captured controlled conditions. We introduce a novel multimodal dataset and benchmark results for continuous PPG recordings during outdoor activities from 16 participants over 13.5 hours, captured from four wearable sensors, each worn at a different location on the body, totaling 216\,hours. Our recordings include accelerometer, temperature, and altitude data, as well as a synchronized Lead I-based electrocardiogram for ground-truth HR references. Participants completed a round trip from Zurich to Jungfraujoch, a tall mountain in Switzerland over the course of one day. The trip included outdoor and indoor activities such as walking, hiking, stair climbing, eating, drinking, and resting at various temperatures and altitudes (up to 3,571\,m above sea level) as well as using cars, trains, cable cars, and lifts for transport -- all of which impacted participants' physiological dynamics. We also present a novel method that estimates HR values more robustly in such real-world scenarios than existing baselines.

cs.CV↗

Tri-Spectral PPG: Robust Reflective Photoplethysmography by Fusing Multiple Wavelengths for Cardiac Monitoring

Multi-channel photoplethysmography (PPG) sensors have found widespread adoption in wearable devices for monitoring cardiac health. Channels thereby serve different functions -- whereas green is commonly used for metrics such as heart rate and heart rate variability, red and infrared are commonly used for pulse oximetry. In this paper, we introduce a novel method that simultaneously fuses multi-channel PPG signals into a single recovered PPG signal that can be input to further processing. Via signal fusion, our learning-based method compensates for the artifacts that affect wavelengths to different extents, such as motion and ambient light changes. We evaluate our method on a novel dataset of multi-channel PPG recordings and electrocardiogram recordings for reference from 10 participants over the course of 13 hours during real-world activities outside the laboratory. Using the fusion PPG signal our method recovered, participants' heart rates can be calculated with a mean error of 4.5\,bpm (23\% lower than from green PPG signals at 5.9\,bpm).

eess.SP↗

EgoPressure: A Dataset for Hand Pressure and Pose Estimation in Egocentric Vision

Touch contact and pressure are essential for understanding how humans interact with and manipulate objects, insights which can significantly benefit applications in mixed reality and robotics. However, estimating these interactions from an egocentric camera perspective is challenging, largely due to the lack of comprehensive datasets that provide both accurate hand poses on contacting surfaces and detailed annotations of pressure information. In this paper, we introduce EgoPressure, a novel egocentric dataset that captures detailed touch contact and pressure interactions. EgoPressure provides high-resolution pressure intensity annotations for each contact point and includes accurate hand pose meshes obtained through our proposed multi-view, sequence-based optimization method processing data from an 8-camera capture rig. Our dataset comprises 5 hours of recorded interactions from 21 participants captured simultaneously by one head-mounted and seven stationary Kinect cameras, which acquire RGB images and depth maps at 30 Hz. To support future research and benchmarking, we present several baseline models for estimating applied pressure on external surfaces from RGB images, with and without hand pose information. We further explore the joint estimation of the hand mesh and applied pressure. Our experiments demonstrate that pressure and hand pose are complementary for understanding hand-object interactions. ng of hand-object interactions in AR/VR and robotics research. Project page: \url{https://yiming-zhao.github.io/EgoPressure/}.

cs.CV↗

Nightbeat: Heart Rate Estimation From a Wrist-Worn Accelerometer During Sleep

Today's fitness bands and smartwatches typically track heart rates (HR) using optical sensors. Large behavioral studies such as the UK Biobank use activity trackers without such optical sensors and thus lack HR data, which could reveal valuable health trends for the wider population. In this paper, we present the first dataset of wrist-worn accelerometer recordings and electrocardiogram references in uncontrolled at-home settings to investigate the recent promise of IMU-only HR estimation via ballistocardiograms. Our recordings are from 42 patients during the night, totaling 310 hours. We also introduce a frequency-based method to extract HR via curve tracing from IMU recordings while rejecting motion artifacts. Using our dataset, we analyze existing baselines and show that our method achieves a mean absolute error of 0.88 bpm -- 76% better than previous approaches. Our results validate the potential of IMU-only HR estimation as a key indicator of cardiac activity in existing longitudinal studies to discover novel health insights. Our dataset, Nightbeat-DB, and our source code are available on GitHub: https://github.com/eth-siplab/Nightbeat.

q-bio.QM↗

Respiro: Continuous Respiratory Rate Monitoring During Motion via Wearable Ultra-Wideband Radar

Deviations in respiratory rate often precede abnormalities in other vital signs. However, continuously monitoring respiratory rates outside clinical settings remains challenging due to the obtrusive nature and sensitivity to body motions in existing monitoring approaches. In this study, we propose a single-point-of-contact wearable device that leverages off-the-shelf, consumer-grade ultra-wideband radar to monitor respiratory rate as part of a chest strap. Our signal processing pipeline reliably extracts the wearer's respiratory signal from windowed complex channel impulse responses. In a controlled experiment, twelve participants performed various activities to evaluate the system's accuracy under motion while capturing ground-truth recordings through a spirometer. Our method extracted respiratory rates with less than 1 breath per minute deviation in 71% of all measurements, averaging 1.11 breaths per minute across all sessions and participants. Our findings underscore the potential of consumer-grade ultra-wideband radar technology in body-worn devices for unobtrusive yet effective respiratory monitoring.

eess.SP↗