SearcharxivSearch

arXiv subjects

Christian Irmler

Publications and source records attributed to Christian Irmler.

8 recordsLinked to original sources

The RD50-MPW4: A Radiation Hard HV CMOS Sensor for Future Colliders

The former CERN RD50 collaboration develops monolithic active pixel high voltage (HV) CMOS sensors for future colliders with the aim of high radiation tolerance, good time resolution, and high granularity pixel detectors. The most recent prototype, the RD50-MPW4, was produced by LFoundry in December 2023 using a 150 nm CMOS process. It features a matrix of 64x64 pixels with a 62 $\mu$m pitch and employs a column-drain readout architecture. Compared to its predecessor, it now has separate analog and digital power domains and a new biasing scheme with a guard ring structure that supports bias voltages over 600 V. This contribution will discuss the design and latest results of the MPW4, where tests with unirradiated samples showed more than 99.9% efficiency, 16 $\mu$m spatial resolution and 10 ns timing resolution. Efficiencies of over 99% were achieved for samples irradiated to fluences of $1 \times 10^{15}$ 1 MeV n$_{\mathrm{eq}}/\mathrm{cm}^2$. A 3D map of the charge collection efficiency from a measurement with two-photon absorption laser is presented that nicely outlines the depletion depth of this radiation hard, high granularity monolithic active pixel sensor.

physics.ins-det

TPA-TCT analysis of the RD50-MPW4 monolithic pixel particle detector

The RD50-MPW4, a Depleted Monolithic Active Pixel Sensor (DMAPS) was analyzed using a Two Photon Absorption Transient Current Technique (TPA-TCT). This technique provides sensitivity maps with micrometer-scale spatial resolution, enabling the resolution of the boundaries of the detector's sensitive volume, even for small-area pixels (62 x 62 $\mu$m$^2$ in this study). With a 3D resolution, the depletion depth, the boundaries of the detector electric field, the 3D hit detection efficiency and the charge sharing between neighboring pixels were measured. The RD50-MPW4, a multi-project wafer chip developed by the HV-CMOS working group within the CERN RD50 collaboration, features a 64 x 64 DMAPS pixel matrix. Illuminating the chip from the backside, the TPA-TCT technique can characterize any pixel element in the matrix because silicon is transparent for near infrared laser light (1550 nm). Electron-hole pairs are generated only around the light focal point, deep in the silicon, so that any charge collected is precisely only from the focal point. With the TPA-TCT technique, the RD50-MPW4 was found to be have a 100% hit detection efficiency under specified conditions and an effective depletion depth of 226 $\mu$m. It was also found that part of the charge in the periphery of the pixel was collected in the neighboring pixel. A 3D map of the sensor clearly shows the in-pixel electronics and the limits of the depletion region.

physics.ins-det

RD50-MPW3: A fully monolithic digital CMOS sensor for future tracking detectors

The CERN-RD50 CMOS working group develops the RD50-MPWseries of monolithic high-voltage CMOS pixel sensors for potential use in future high luminosity experiments such as the HL-LHC and FCC-hh. In this contribution, the design of the latest prototype in this series, RD50-MPW3, is presented. An overview of its pixel matrix and digital readout periphery is given, with discussion of the new structures implemented in the chip and the problems they aim to solve. The main analog and digital features of the sensor are already tested and initial laboratory characterisation of the chip is presented.

physics.ins-det

Readout system and testbeam results of the RD50-MPW2 HV-CMOS pixel chip

The RD50-CMOS group aims to design and study High Voltage CMOS (HVCMOS) chips for use in a high radiation environment. Currently, measurements are performed on RD50-MPW2 chip, the second prototype developed by this group. The active matrix of the prototype consists of 8x8 pixels with analog front end. Details of the analog front end and simulations have been already published earlier. This contribution focuses on the Caribou based readout system of the active matrix. Each pixel of the active matrix can be readout one after the other. Relevant aspects of hardware, firmware and software are introduced. As a first stage, firmware for a standalone setup is introduced and details on data flow are given. Afterwards, a second stage of the firmware capable of synchronizing with other detectors and accepting triggers is presented, focusing on operation of the chip in combination with a tracking telescope to measure efficiency and residuals.

physics.ins-det

Novel ion imaging concept based on time-of-flight measurements with low gain avalanche detectors

Treatment planning in ion beam therapy requires accurate knowledge of the relative stopping power (RSP) distribution within the patient. Currently, RSP maps are obtained via conventional x-ray computed tomography (CT) by converting the measured attenuation coefficients of photons into RSP values for ions. Alternatively, to avoid conversion errors that are inherent to this method, ion computed tomography (iCT) can be used since it allows determining the RSP directly. In typical iCT systems, which usually consist of a tracking system and a separate residual energy detector, the RSP is obtained by measuring the particle trajectory and the corresponding water equivalent path length (WEPL) of single ions travelling through the patient. Within this work, we explore a novel iCT approach which does not require a residual energy detector. Instead, the WEPL is estimated indirectly by determining the change in time of flight (TOF) due to the energy loss along the ion's path. For this purpose, we have created a Geant4 model of a TOF-iCT system based on low gain avalanche detectors (LGADs), which are fast 4D-tracking detectors that can measure the time of arrival and position of individual particles with high spatial and time precision. To assess the performance of this TOF-iCT concept, we determined the RSP resolution and accuracy for different system settings using the Catphan CTP404 sensitometry phantom. Within the set of investigated system parameters, the lower limit of the RSP accuracy was found at 0.91%, demonstrating the proof-of-principle of this novel TOF-iCT concept. The main advantage of using this approach is that it could potentially facilitate clinical integration due to its compact design, which, however, requires experimental verification and an improvement of the current WEPL calibration procedure.

physics.med-ph

Feasibility study of a proton CT system based on 4D-tracking and residual energy determination via time-of-flight

For dose calculations in ion beam therapy, it is vital to accurately determine the relative stopping power (RSP) distribution within the treated volume. Currently, RSP values are extrapolated from Hounsfield units (HU), measured with x-ray computed tomography (CT), which entails RSP inaccuracies due to conversion errors. A suitable method to improve the treatment plan accuracy is proton computed tomography (pCT). A typical pCT system consists of a tracking system and a separate residual energy (or range) detector to measure the RSP distribution directly. This paper introduces a novel pCT system based on a single detector technology, namely low gain avalanche detectors (LGADs). LGADs are fast 4D-tracking detectors, which can be used to simultaneously measure the particle position and time with precise timing and spatial resolution. In contrast to standard pCT systems, the residual energy is determined via a time-of-flight (TOF) measurement between different 4D-tracking stations. The design parameters for a realistic proton computed tomography system based on 4D-tracking detectors were studied and optimized using Monte Carlo simulations. The RSP accuracy and RSP resolution were measured inside the inserts of the CTP404 phantom to estimate the performance of the pCT system. After introducing a dedicated calibration procedure for the TOF calorimeter, RSP accuracies < 0.6 % could be achieved. Furthermore, the design parameters with the strongest impact on the RSP resolution were identified and a strategy to improve RSP resolution is proposed.

physics.med-ph

A Proton Computed Tomography Demonstrator for Stopping Power Measurements

Particle therapy is an established method to treat deep-seated tumours using accelerator-produced ion beams. For treatment planning, the precise knowledge of the relative stopping power (RSP) within the patient is vital. Conversion errors from x-ray computed tomography (CT) measurements to RSP introduce uncertainties in the applied dose distribution. Using a proton computed tomography (pCT) system to measure the SP directly could potentially increase the accuracy of treatment planning. A pCT demonstrator, consisting of double-sided silicon strip detectors (DSSD) as tracker and plastic scintillator slabs coupled to silicon photomultipliers (SiPM) as a range telescope, was developed. After a significant hardware upgrade of the range telescope, a 3D tomogram of an aluminium stair phantom was recorded at the MedAustron facility in Wiener Neustadt, Austria. In total, 80 projections with 6.5x10^5 primary events were acquired and used for the reconstruction of the RSP distribution in the phantom. After applying a straight-line approximation for the particle path inside the phantom, the most probable value (MPV) of the RSP distribution could be measured with an accuracy of 0.59%. The RSP resolution inside the phantom was only 9.3% due to a limited amount of projections and measured events per projection.

physics.med-ph

Commissioning of low particle flux for proton beams at MedAustron

MedAustron is a synchrotron-based particle therapy centre located in Wiener Neustadt, Austria. It features three irradiation rooms for particle therapy, where proton beams with energies up to 252.7 MeV and carbon ions of up to 402.8 MeV/u are available for cancer treatment. In addition to the treatment rooms, MedAustron features a unique beamline exclusively for non-clinical research (NCR). This research beamline is also commissioned for proton energies up to 800 MeV, while available carbon ion energies correspond to the ones available in the clinical treatment rooms. Based on the requirements for particle therapy, all irradiation rooms offer particle rates of up to 10^9 particles/s for protons and 10^7 particles/s for carbon ions. However, for research purposes, lower particle fluxes are required and were therefore commissioned for the NCR beamline. Three particle flux settings with particle rates ranging from ~2.4x10^3 particles/s to ~5.2x10^6 particles/s were established for seven proton energies below 252.7 MeV. In addition to the particle rate, the spot sizes and beam energies were measured for these settings. Furthermore, three low flux settings for 800 MeV protons with particle rates ranging from ~2x10^3 particles/s to ~1.3x10^6 particles/s were commissioned. Since the commissioned low flux settings are in a regime well below the limits of the available standard beam diagnostics, setting up the beam under these new operational conditions entirely relied on the use of external detectors. Furthermore, a beam position measurement based alignment without using the standard beam profile monitors was performed for 800 MeV protons.

physics.acc-ph