Searcharxiv⌕ Search

arXiv subjects

Christian Lisdat

Publications and source records attributed to Christian Lisdat.

At least 37 records · Page 2Linked to original sources

Dynamic decoupling of laser phase noise in compound atomic clocks

The frequency stability achieved by an optical atomic clock ultimately depends on the coherence of its local oscillator. Even the best ultrastable lasers only allow interrogation times of a few seconds, at present. Here we present a universal measurement protocol that overcomes this limitation. Engineered dynamic decoupling of laser phase noise allows any optical atomic clock with high signal-to-noise ratio in a single interrogation to reconstruct the laser's phase well beyond its coherence limit. A compound clock is then formed in combination with another optical clock of any type, allowing the latter to achieve significantly higher frequency stability than on its own. We demonstrate implementation of the protocol in a realistic proof-of-principle experiment with a phase reconstruction fidelity of 99 %. The protocol enables minute-long interrogation for the best ultrastable laser systems. Likewise, it can improve clock performance where less stable local oscillators are used, such as in transortable systems.

physics.atom-ph↗

Guidelines for developing optical clocks with $10^{-18}$ fractional frequency uncertainty

There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency standards. This exceptional accuracy and stability is resulting in a growing number of research groups developing optical clocks. While good review papers covering the topic already exist, more practical guidelines are needed as a complement. The purpose of this document is therefore to provide technical guidance for researchers starting in the field of optical clocks. The target audience includes national metrology institutes (NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD students and postdocs entering the field. Another potential audience is academic groups with experience in atomic physics and atom or ion trapping, but with less experience of time and frequency metrology and optical clock requirements. These guidelines have arisen from the scope of the EMPIR project "Optical clocks with $1 \times 10^{-18}$ uncertainty" (OC18). Therefore, the examples are from European laboratories even though similar work is carried out all over the world. The goal of OC18 was to push the development of optical clocks by improving each of the necessary subsystems: ultrastable lasers, neutral-atom and single-ion traps, and interrogation techniques. This document shares the knowledge acquired by the OC18 project consortium and gives practical guidance on each of these aspects.

physics.atom-ph↗

Lattice-induced photon scattering in an optical lattice clock

We investigate scattering of lattice laser radiation in a strontium optical lattice clock and its implications for operating clocks at interrogation times up to several tens of seconds. Rayleigh scattering does not cause significant decoherence of the atomic superposition state near a magic wavelength. Among the Raman scattering processes, lattice-induced decay of the excited state $(5s5p)\,{}^{3}\mathrm{P}_{0}$ to the ground state $(5s^2)\,{}^{1}\mathrm{S}_{0}$ via the state $(5s5p)\,{}^{3}\mathrm{P}_{1}$ is particularly relevant, as it reduces the effective lifetime of the excited state and gives rise to quantum projection noise in spectroscopy. We observe this process in our experiment and find a decay rate of $556(15)\times 10^{-6}\,\mathrm{s}^{-1}$ per photon recoil energy $E_\mathrm{r}$ of effective lattice depth, which agrees well with the rate we predict from atomic data. We also derive a natural lifetime $τ= 330(140)\,\mathrm{s}$ of the excited state ${}^{3}\mathrm{P}_{0}$ from our observations. Lattice-induced decay thus exceeds spontaneous decay at typical lattice depths used by present clocks. It eventually limits interrogation times in clocks restricted to high-intensity lattices, but can be largely avoided, e.g., by operating them with shallow lattice potentials.

physics.atom-ph↗

A high-performance optical lattice clock based on bosonic atoms

Optical lattice clocks with uncertainty and instability in the $10^{-17}$-range and below have so far been demonstrated exclusively using fermions. Here, we demonstrate a bosonic optical lattice clock with $3\times 10^{-18}$ instability and $2.0\times 10^{-17}$ accuracy, both values improving on previous work by a factor 30. This was enabled by probing the clock transition with an ultra-long interrogation time of 4 s, using the long coherence time provided by a cryogenic silicon resonator, by careful stabilization of relevant operating parameters, and by operating at low atom density. This work demonstrates that bosonic clocks, in combination with highly coherent interrogation lasers, are suitable for high-accuracy applications with particular requirements, such as high reliability, transportability, operation in space, or suitability for particular fundamental physics topics. As an example, we determine the $^{88}\textrm{Sr} - ^{87}$Sr isotope shift with 12 mHz uncertainty.

physics.atom-ph↗

Atomic Clocks for Geodesy

We review experimental progress on optical atomic clocks and frequency transfer, and consider the prospects of using these technologies for geodetic measurements. Today, optical atomic frequency standards have reached relative frequency inaccuracies below 10-17, opening new fields of fundamental and applied research. The dependence of atomic frequencies on the gravitational potential makes atomic clocks ideal candidates for the search for deviations in the predictions of Einstein's general relativity, tests of modern unifying theories and the development of new gravity field sensors. In this review, we introduce the concepts of optical atomic clocks and present the status of international clock development and comparison. Besides further improvement in stability and accuracy of today's best clocks, a large effort is put into increasing the reliability and technological readiness for applications outside of specialized laboratories with compact, portable devices. With relative frequency uncertainties of 10-18, comparisons of optical frequency standards are foreseen to contribute together with satellite and terrestrial data to the precise determination of fundamental height reference systems in geodesy with a resolution at the cm-level. The long-term stability of atomic standards will deliver excellent long-term height references for geodetic measurements and for the modelling and understanding of our Earth.

physics.atom-ph↗

Geodesy and metrology with a transportable optical clock

The advent of novel measurement instrumentation can lead to paradigm shifts in scientific research. Optical atomic clocks, due to their unprecedented stability and uncertainty, are already being used to test physical theories and herald a revision of the International System of units (SI). However, to unlock their potential for cross-disciplinary applications such as relativistic geodesy, a major challenge remains. This is their transformation from highly specialized instruments restricted to national metrology laboratories into flexible devices deployable in different locations. Here we report the first field measurement campaign performed with a ubiquitously applicable $^{87}$Sr optical lattice clock. We use it to determine the gravity potential difference between the middle of a mountain and a location 90 km apart, exploiting both local and remote clock comparisons to eliminate potential clock errors. A local comparison with a $^{171}$Yb lattice clock also serves as an important check on the international consistency of independently developed optical clocks. This campaign demonstrates the exciting prospects for transportable optical clocks.

physics.atom-ph↗

Noise and instability of an optical lattice clock

We present an analysis of the different types of noise from the detection and interrogation laser in our strontium lattice clock. We develop a noise model showing that in our setup quantum projection noise--limited detection is possible if more than 130~atoms are interrogated. Adding information about the noise spectrum of our clock laser with sub-$10^{-16}$ fractional frequency instability allows to infer the clock stability for different modes of operation. Excellent agreement with experimental observations for the instability of the difference between two interleaved stabilizations is found. We infer a clock instability of $1.6 \times 10^{-16}/\sqrt{τ/ \mathrm{s}}$ as a function of averaging time $τ$ for normal clock operation.

physics.atom-ph↗

On the relation between uncertainties of weighted frequency averages and the various types of Allan deviations

The power spectral density in Fourier frequency domain, and the different variants of the Allan deviation (ADEV) in dependence on the averaging time are well established tools to analyse the fluctuation properties and frequency instability of an oscillatory signal. It is often supposed that the statistical uncertainty of a measured average frequency is given by the ADEV at a well considered averaging time. However, this approach requires further mathematical justification and refinement, which has already been done regarding the original ADEV for certain noise types. Here we provide the necessary background to use the modified Allan deviation (modADEV) and other two-sample deviations to determine the uncertainty of weighted frequency averages. The type of two-sample deviation used to determine the uncertainty depends on the method used for determination of the average. We find that the modADEV, which is connected with $Λ$-weighted averaging, and the two sample deviation associated to a linear phase regression weighting (parADEV) are in particular advantageous for measurements, in which white phase noise is dominating. Furthermore, we derive a procedure how to minimize the uncertainty of a measurement for a typical combination of white phase and frequency noise by adaptive averaging of the data set with different weighting functions. Finally, some aspects of the theoretical considerations for real-world frequency measurement equipment are discussed.

physics.data-an↗

8E-17 fractional laser frequency instability with a long room-temperature cavity

We present a laser system based on a 48 cm long optical glass resonator. The large size requires a sophisticated thermal control and optimized mounting design. A self balancing mounting was essential to reliably reach sensitivities to acceleration of below $Δν/ ν$ < 2E-10 /g in all directions. Furthermore, fiber noise cancellations from a common reference point near the laser diode to the cavity mirror and to additional user points (Sr clock and frequency comb) are implemented. Through comparison to other cavity-stabilized lasers and to a strontium lattice clock an instability of below 1E-16 at averaging times from 1 s to 1000 s is revealed.

physics.optics↗

A strontium lattice clock with $3 \times 10^{-17}$ inaccuracy and its frequency

We have measured the absolute frequency of the optical lattice clock based on $^{87}$Sr at PTB with an uncertainty of $3.9\times 10^{-16}$ using two caesium fountain clocks. This is close to the accuracy of today's best realizations of the SI second. The absolute frequency of the 5s$^2$ $^1$S$_0$-5s5p $^3$P$_0$ transition in $^{87}$Sr is 429,228,004,229,873.13(17) Hz. Our result is in excellent agreement with recent measurements performed in different laboratories worldwide. We improved the total systematic uncertainty of our Sr frequency standard by a factor of five and reach $3\times 10^{-17}$, opening new prospects for frequency ratio measurements between optical clocks for fundamental research, geodesy, or optical clock evaluation.

physics.atom-ph↗

Ultra-stable laser with average fractional frequency drift rate below $5\times10^{-19}/\mathrm{s}$

Cryogenic single-crystal optical cavities have the potential to provide highest dimensional stability. We have investigated the long-term performance of an ultra-stable laser system which is stabilized to a single-crystal silicon cavity operated at 124 K. Utilizing a frequency comb, the laser is compared to a hydrogen maser that is referenced to a primary caesium fountain standard and to the $^{87}\mathrm{Sr}$ optical lattice clock at PTB. With fractional frequency instabilities of $σ_y(τ)\leq2\times10^{-16}$ for averaging times of $τ=60\mathrm{~s}$ to $1000\mathrm{~s}$ and $σ_y(1 \mathrm{d})\leq 2\times10^{-15}$ the stability of this laser, without any aid from an atomic reference, surpasses the best microwave standards for short averaging times and is competitive with the best hydrogen masers for longer times of one day. The comparison of modeled thermal response of the cavity with measured data indicates a fractional frequency drift below $5\times 10^{-19}/\mathrm{s}$, which we do not expect to be a fundamental limit.

physics.optics↗

High accuracy correction of blackbody radiation shift in an optical lattice clock

We have determined the frequency shift that blackbody radiation is inducing on the $5s^2$ $^1$S$_0$ -- $5s5p$ $^3$P$_0$ clock transition in strontium. Previously its uncertainty limited the uncertainty of strontium lattice clocks to $1\times10^{-16}$. Now the uncertainty associated to the black body radiation shift correction translates to $5\times 10^{-18}$ relative frequency uncertainty at room temperature. Our evaluation is based on a measurement of the differential dc-polarizability of the two clock states and on a modeling of the dynamic contribution using this value and experimental data for other atomic properties.

physics.atom-ph↗

A compact and efficient strontium oven for laser-cooling experiments

Here we describe a compact and efficient strontium oven well suited for laser-cooling experiments. Novel design solutions allowed us to produce a collimated strontium atomic beam with a flux of 1.0\times10^13 s^-1 cm^-2 at the oven temperature of 450 °C, reached with an electrical power consumption of 36 W. The oven is based on a stainless-steel reservoir, filled with 6 g of metallic strontium, electrically heated in a vacuum environment by a tantalum wire threaded through an alumina multi-bore tube. The oven can be hosted in a standard DN40CF cube and has an estimated continuous operation lifetime of 10 years. This oven can be used for other alkali and alkaline earth metals with essentially no modifications.

physics.atom-ph↗

Long range transport of ultra cold atoms in a far-detuned 1D optical lattice

We present a novel method to transport ultra cold atoms in a focused optical lattice over macroscopic distances of many Rayleigh ranges. With this method ultra cold atoms were transported over 5 cm in 250 ms without significant atom loss or heating. By translating the interference pattern together with the beam geometry the trap parameters are maintained over the full transport range. Thus, the presented method is well suited for tightly focused optical lattices that have sufficient trap depth only close to the focus. Tight focusing is usually required for far-detuned optical traps or traps that require high laser intensity for other reasons. The transport time is short and thus compatible with the operation of an optical lattice clock in which atoms are probed in a well designed environment spatially separated from the preparation and detection region.

physics.atom-ph↗

Delivering pulsed and phase stable light to atoms of an optical clock

In optical clocks, transitions of ions or neutral atoms are interrogated using pulsed ultra-narrow laser fields. Systematic phase chirps of the laser or changes of the optical path length during the measurement cause a shift of the frequency seen by the interrogated atoms. While the stabilization of cw-optical links is now a well established technique even on long distances, phase stable links for pulsed light pose additional challanges and have not been demonstrated so far. In addition to possible temperature or pressure drift of the laboratory, which may lead to a Doppler shift by steadily changing the optical path length, the pulsing of the clock laser light calls for short settling times of stabilization locks. Our optical path length stabilization uses retro-reflected light from a mirror that is fixed with respect to the interrogated atoms and synthetic signals during the dark time. Length changes and frequency chirps are compensated for by the switching AOM. For our strontium optical lattice clock we have ensured that the shift introduced by the fiber link including the pulsing acousto optic modulator is below $2\cdot 10^{-17}$.

physics.atom-ph↗

Demonstration of a Transportable 1 Hz-Linewidth Laser

We present the setup and test of a transportable clock laser at 698 nm for a strontium lattice clock. A master-slave diode laser system is stabilized to a rigidly mounted optical reference cavity. The setup was transported by truck over 400 km from Braunschweig to Düsseldorf, where the cavity-stabilized laser was compared to a stationary clock laser for the interrogation of ytterbium (578 nm). Only minor realignments were necessary after the transport. The lasers were compared by a Ti:Sapphire frequency comb used as a transfer oscillator. The thus generated virtual beat showed a combined linewidth below 1 Hz (at 1156 nm). The transport back to Braunschweig did not degrade the laser performance, as was shown by interrogating the strontium clock transition.

physics.optics↗

Tackling the blackbody shift in a strontium optical lattice clock

A major obstacle for optical clocks is the frequency shift due to black body radiation. We discuss how one can tackle this problem in an optical lattice clock; in our case 87-Sr: firstly, by a measurement of the dc Stark shift of the clock transition and, secondly, by interrogating the atoms in a cryogenic environment. Both approaches rely on transporting ultracold atoms over several cm within a probe cycle. We evaluate this approach of mechanically moving the optical lattice and conclude that it is feasible to transport the atoms over 50 mm within 300 ms. With this transport a dc Stark shift measurement will allow to reduce the contribution of the blackbody radiation to the fractional uncertainty below 2 * 10^-17 at room temperature by improving the shift coefficient known only from atomic structure calculations up to now. We propose a cryogenic environment at 77 K that will reduce this contribution to few parts in 10^-18.

physics.atom-ph↗

Potassium ground state scattering parameters and Born-Oppenheimer potentials from molecular spectroscopy

We present precision measurements with MHz uncertainty of the energy gap between asymptotic and well bound levels in the electronic ground state X $^1Σ_{\mathrm{g}}^+$ of the $^{39}$K$_2$ molecule. The molecules are prepared in a highly collimated particle beam and are interrogated in a $Λ$-type excitation scheme of optical transitions to long range levels close to the asymptote of the ground state, using the electronically excited state A $^1Σ^+_{\rm u}$ as intermediate one. The transition frequencies are measured either by comparison with I$_2$ lines or by absolute measurements using a fs-frequency comb. The determined level energies were used together with Feshbach resonances from cold collisions of $^{39}$K and $^{40}$K reported from other authors to fit new ground state potentials. Precise scattering lengths are determined and tests of the validity of the Born-Oppenheimer approximation for the description of cold collisions at this level of precision are performed.

physics.atom-ph↗