Christian Ruder

Publications and source records attributed to Christian Ruder.

5 recordsLinked to original sources

Characterization of iLGADs using soft X-rays

Experiments at synchrotron radiation sources and X-ray Free-Electron Lasers in the soft X-ray energy range ($250$eV--$2$keV) stand to benefit from the adaptation of the hybrid silicon detector technology for low energy photons. Inverse Low Gain Avalanche Diode (iLGAD) sensors provide an internal gain, enhancing the signal-to-noise ratio and allowing single photon detection below $1$keV using hybrid detectors. In addition, an optimization of the entrance window of these sensors enhances their quantum efficiency (QE). In this work, the QE and the gain of a batch of different iLGAD diodes with optimized entrance windows were characterized using soft X-rays at the Surface/Interface:Microscopy beamline of the Swiss Light Source synchrotron. Above $250$eV, the QE is larger than $55\%$ for all sensor variations, while the charge collection efficiency is close to $100\%$. The average gain depends on the gain layer design of the iLGADs and increases with photon energy. A fitting procedure is introduced to extract the multiplication factor as a function of the absorption depth of X-ray photons inside the sensors. In particular, the multiplication factors for electron- and hole-triggered avalanches are estimated, corresponding to photon absorption beyond or before the gain layer, respectively.

physics.ins-det

Development of LGAD sensors with a thin entrance window for soft X-ray detection

We show the developments carried out to improve the silicon sensor technology for the detection of soft X-rays with hybrid X-ray detectors. An optimization of the entrance window technology is required to improve the quantum efficiency. The LGAD technology can be used to amplify the signal generated by the X-rays and to increase the signal-to-noise ratio, making single photon resolution in the soft X-ray energy range possible. In this paper, we report first results obtained from an LGAD sensor production with an optimized thin entrance window. Single photon detection of soft X-rays down to 452~eV has been demonstrated from measurements, with a signal-to-noise ratio better than 20.

physics.ins-det

Design and first tests of the Gotthard-II readout ASIC for the European X-ray Free-Electron Laser

Gotthard-II is a charge-integrating microstrip detector developed for experiments and diagnostics at free-electron lasers using hard X-rays of 5 keV - 20 keV. Thanks to its excellent single photon sensitivity, large dynamic range as well as high frame rate of 4.5 MHz in burst mode, its potential scientific applications include X-ray absorption/emission spectroscopy, hard X-ray high resolution single-shot spectrometry (HiREX), beam diagnostics, as well as veto signal generation for pixel detectors. The Gotthard-II ASIC has been designed and fabricated using UMC-110 nm technology. The final ASIC design and performance in terms of noise, linearity, dynamic range, coupling between channels and speed will be discussed in the paper. In addition, a first measurement of an X-ray absorption spectrum of a standard copper sample has been done. The performance of the Gotthard-II in an experiment using energy dispersive X-rays has been demonstrated.

physics.ins-det

Performance Evaluation of the Analogue Front-End and ADC Prototypes for the Gotthard-II Development

Gotthard-II is a silicon microstrip detector developed for the European X-ray Free-Electron Laser (XFEL.EU). Its potential scientific applications include X-ray absorption/emission spectroscopy, hard X-ray high resolution single-shot spectrometry (HiREX), energy dispersive experiments at 4.5 MHz frame rate, beam diagnostics, as well as veto signal generation for pixel detectors. Gotthard-II uses a silicon microstrip sensor with a pitch of 50 $μ$m or 25 $μ$m and with 1280 or 2560 channels wire-bonded to readout chips (ROCs). In the ROC, an adaptive gain switching pre-amplifier (PRE), a fully differential Correlated-Double-Sampling (CDS) stage, an Analog-to-Digital Converter (ADC) as well as a Static Random-Access Memory (SRAM) capable of storing all the 2700 images in an XFEL.EU bunch train will be implemented. Several prototypes with different designs of the analogue front-end (PRE and CDS) and ADC test structures have been fabricated in UMC-110 nm CMOS technology and their performance has been evaluated. In this paper, the performance of the analogue front-end and ADC will be summarized.

physics.ins-det

Towards Gotthard-II: Development of A Silicon Microstrip Detector for the European X-ray Free-Electron Laser

Gotthard-II is a 1-D microstrip detector specifically developed for the European X-ray Free-Electron Laser. It will not only be used in energy dispersive experiments but also as a beam diagnostic tool with additional logic to generate veto signals for the other 2-D detectors. Gotthard-II makes use of a silicon microstrip sensor with a pitch of either 50 μm or 25 μm and with 1280 or 2560 channels wire-bonded to adaptive gain switching readout chips. Built-in analog-to-digital converters and digital memories will be implemented in the readout chip for a continuous conversion and storage of frames for all bunches in the bunch train. The performance of analogue front-end prototypes of Gotthard has been investigated in this work. The results in terms of noise, conversionngain, dynamic range, obtained by means of infrared laser and X-rays, will be shown. In particular, the effects of the strip-to-strip coupling are studied in detail and it is found that the reduction of the coupling effects is one of the key factors for the development of the analogue front-end of Gotthard-II.