Fast Maximum Likelihood Positioning for a Staggered Layer Scintillation PET Detector

In this study, we propose a fast implementation of a Maximum Likelihood Positioning (MLP) algorithm to estimate the energy and identify the active scintillator pixel in staggered layer scintillation detectors for PET. The staggered layer design with pixelated scintillators enables the determination of the gamma's depth of interaction and facilitates an iteration-free formulation of the MLP algorithm. The efficacy of the algorithm optimization was tested on a scintillation detector block designed for an ultra-high field BrainPET 7T, comprising three scintillator pixel layers. The three layers contain 24 x 24, 24 x 23 and 23 x 22 scintillator pixels, respectively, with a pixel pitch of 2 mm in both directions and layer thicknesses of 9, 8 and 7 mm. Calibration measurements, in combination with an automated calibration script, were used to obtain the expected counts of scintillation photons required in the MLP algorithm. Using Single-Instruction-Multiple-Data parallelization, multi-threading and optimized cache lines, a maximum processing speed of approximately 22.5 million singles per second was achieved on a platform with four Intel Xeon Platinum 8168 CPUs and 60 threads, encompassing all required processing steps. The automatic calibration failed for 1 to 15 individual scintillator pixels in approximately 10 per cent of the 120 scintillation detector blocks, necessitating manual correction. After applying the energy correction to the positioned single events, an energy resolution of of 12 +/- 2 per cent FWHM was obtained for the entire scintillation block. This value is very close to the energy resolutions measured for the individual scintillator pixels, proving that the MLP accurately identifies the scintillating pixel and that the energy correction method effectively compensates for the light collection variations of the SiPM array.

physics.ins-det↗

Depth of Interaction Enhanced Gamma-Ray Imaging for Medical Applications

A novel design for an inexpensive depth of interaction capable detector for gamma rays, suitable for nuclear medical applications, especially Positron Emission Tomography, has been developed. The design takes advantage of the strong correlation between the width of the scintillation light distribution in continuous crystals and the depth of interaction of the gamma-ray. For measuring the distribution width, an inexpensive modification of the commonly used charge dividing circuits that allows analogue and instantaneous computation of the 2nd moment has been developed and is presented in this work. The method has been tested with a detector made of a continuous LSO-scintillator of dimensions 42x42x10 cubic mm and optically coupled to the compact large area position sensitive photomultiplier H8500 from Hamamatsu. The mean resolution in all non-trivial moments was found to be smaller than 5% but their direct use as estimates for the three-dimensional photoconversion position turned out to be unsuitable. Standard polynomial interpolation in higher dimensions has been adopted to reconstruct the impact positions of the gamma-rays from the measured moments. When using the reconstructed impact positions, the intrinsic mean spatial resolution of the detector was found to be 1.9 mm for the transverse components and 3.9 mm for the depth of interaction. Using directly the bare moments as position estimate, the intrinsic mean spatial resolution of the detector was found to be 3.4 mm and 4.9 mm, respectively. The cost for the required detector improvements are essentially negligible.

physics.med-ph↗