In this study, we propose a fast implementation of a Maximum Likelihood Positioning (MLP) algorithm to estimate the energy and identify the active scintillator pixel in staggered layer scintillation detectors for PET. The staggered layer design with pixelated scintillators enables the determination of the gamma's depth of interaction and facilitates an iteration-free formulation of the MLP algorithm. The efficacy of the algorithm optimization was tested on a scintillation detector block designed for an ultra-high field BrainPET 7T, comprising three scintillator pixel layers. The three layers contain 24 x 24, 24 x 23 and 23 x 22 scintillator pixels, respectively, with a pixel pitch of 2 mm in both directions and layer thicknesses of 9, 8 and 7 mm. Calibration measurements, in combination with an automated calibration script, were used to obtain the expected counts of scintillation photons required in the MLP algorithm. Using Single-Instruction-Multiple-Data parallelization, multi-threading and optimized cache lines, a maximum processing speed of approximately 22.5 million singles per second was achieved on a platform with four Intel Xeon Platinum 8168 CPUs and 60 threads, encompassing all required processing steps. The automatic calibration failed for 1 to 15 individual scintillator pixels in approximately 10 per cent of the 120 scintillation detector blocks, necessitating manual correction. After applying the energy correction to the positioned single events, an energy resolution of of 12 +/- 2 per cent FWHM was obtained for the entire scintillation block. This value is very close to the energy resolutions measured for the individual scintillator pixels, proving that the MLP accurately identifies the scintillating pixel and that the energy correction method effectively compensates for the light collection variations of the SiPM array.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Christoph W. Lerche, Wenwei Bi, Mirjam Schoeneck, Debora Niekaemper, Qi Liu, Elisabeth Pfaehler, Lutz Tellmann, Juergen J. Scheins, N. Jon Shah. 2025-03-17. Fast Maximum Likelihood Positioning for a Staggered Layer Scintillation PET Detector. https://doi.org/10.1088/1361-6560%2Fadf8ab

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det