Christophe Hoarau

Publications and source records attributed to Christophe Hoarau.

12 recordsLinked to original sources

Characterization of Aluminum Microwave SQUID Multiplexers for CE$\nu$NS Detection

We present the design, fabrication, and characterization of an aluminum-based six-channel microwave SQUID multiplexer ($\mu$MUX) prototype for transition-edge sensor (TES) readout in the RICOCHET experiment. The device consists of aluminum coplanar-waveguide resonators and RF SQUIDs with Dolan-style Al/AlO$_x$/Al Josephson junctions. By measuring the resonator scattering parameters at a range of probe tone frequencies, powers, and flux bias points, we demonstrate agreement between the device response and existing multiplexer models. We also characterize the noise performance in both open-loop and flux-ramping modes. With a high electron mobility transistor (HEMT) amplifier, open-loop measurements yield a flux sensitivity of 1-1.5 $\mu\Phi_0/\sqrt{Hz}$. With flux-ramp modulation, low-frequency 1/f noise is suppressed, and the flux sensitivity is around 3-4 $\mu\Phi_0/\sqrt{Hz}$, corresponding to a current sensitivity of 24-33 $pA/\sqrt{Hz}$ at the input coil. We further demonstrate a reduction in readout noise by incorporating a Josephson traveling-wave parametric amplifier (JTWPA) between the $\mu$MUX and the HEMT. This achieves an open-loop flux sensitivity of 0.3-0.6 $\mu\Phi_0/\sqrt{Hz}$ and an effective system noise temperature below 1 K. These results establish aluminum $\mu$MUX devices as a viable and extensible readout technology for low-noise cryogenic detector arrays.

physics.ins-det

CONCERTO : Optimization of readout electronics

The CONCERTO millimeter-wave spectral-imaging instrument was deployed on the Atacama Pathfinder EXperiment (APEX), where it acquired science data between April 2021 and May 2023. The instrument features two focal-plane arrays, each composed of 2400 Microwave Kinetic Inductance Detectors (MKIDs). Each array is divided into six feedlines containing 400 MKIDs each, with each feedline read out by a dedicated FPGA-based board, KID_READOUT. The next-generation instrument aims to double the detector count per feedline, increasing it from 400 to 800 MKIDs. Achieving this requires a substantial scaling of the readout architecture and poses two key challenges for KID_READOUT: maintaining readout signal integrity and constraining firmware resource usage, as a direct upscaling of the existing design would exceed the available FPGA capacity. To overcome these limitations, we developed a Python-based, cycle-and bit-accurate digital twin of the full FPGA digital signal processing chain. This model enabled a detailed investigation of internal signal behavior and provided quantitative guidance for firmware optimization. Leveraging these insights, we identified the source of two spurs present in CONCERTO data and significantly reduced their amplitudes. At the same time, we achieved substantial reductions in firmware resource usage-39.0%pt in LUTs, 20.3%pt in flip-flops, and 28.98%pt in DSP slices-without degrading readout performance. The resulting architecture supports more than 800 MKIDs per feedline on the same hardware platform while preserving readout signal quality, offering a scalable and resource-efficient solution for future high-resolution millimeter-wave astronomical instruments.

eess.SP

A Digital Twin of the FPGA Digital Signal Processing Chain for MKIDs Readout: Root-Cause Analysis and Mitigation of Spurs

The KID_READOUT board, developed for the CONCERTO millimeter-wave astronomy instrument, implements FPGA-based digital frequency multiplexing to read out large arrays of Microwave Kinetic Inductance Detectors (MKIDs). The complexity of the implemented multirate DSP chain, which combines tones synthesis, interpolation, digital frequency translation, polyphase filter-bank (PFB) channelization, and digital down-conversion (DDC), makes analytical performance optimization difficult. To address this, we developed a cycle-and bitaccurate, Python-based digital twin of the FPGA readout firmware DSP chain. Using this model, we identified the origin of previously measured and unexplained spurs in the readout channels, tracing them to periodicity mismatches between the excitation and analysis paths and to insufficient suppression of negative-frequency components by the DDC filters. Based on these insights, we implemented a mitigation strategy that aligns the periodicities and improves the DDC filter characteristics, effectively eliminating the spurs with a minor increase in FPGA resource usage.

eess.SP

Prompt Gamma Timing in Carbon Therapy: First Experimental Results with the TIARA Detector

In the context of range monitoring for particle therapy, this study presents the first experimental results obtained with the TIARA detector using carbon-ion beams at the CNAO clinical center in Pavia, Italy. TIARA is based on the Prompt Gamma Timing (PGT) technique, which measures the time of flight (TOF) between incident ions and prompt gamma rays (PGs) emitted during nuclear interactions in the target. While the TIARA prototype has previously been validated with protons, carbons present a more challenging scenario due to their higher linear energy transfer, nuclear fragmentation products, and the continuous beam time structure of synchrotron accelerators. Experiments were performed by irradiating PMMA targets of different thicknesses with 200 MeV/u carbon beams. A coincidence time resolution of 279$\pm$35 ps FWHM was achieved, outperforming results previously obtained with protons at the same facility. A range accuracy of 4.74$\pm$0.36 mm at a 2$\sigma$ confidence level was measured at clinical intensity, when considering 5600 detected PGs, corresponding to the grouping of four irradiation spots of 2.4$\cdot$10$^6$ ions each. Overall, the results demonstrate that PGT-based range monitoring remains viable for carbon-ion beams, although increased background from secondary protons indicates that detector configuration adaptations are required.

physics.med-ph

Characterization of mini-CryoCube detectors from the Ricochet experiment commissioning at the Institut Laue-Langevin

The Ricochet experiment aims to measure the coherent elastic neutrino-nucleus scattering process from antineutrinos emitted by a research nuclear reactor operated by the Institut Laue-Langevin (Grenoble, France). This article presents a description of the Ricochet experimental installation and the detector performance achieved during its commissioning with a mini-CryoCube module consisting of three 42-gram germanium cryogenic calorimeters. The baseline resolutions and background levels are reported both during reactor-on and reactor-off periods, and as noise mitigation techniques were improved. A baseline resolution of 40 eV electron equivalent was achieved for the ionization channel after setup improvements, and the phonon channel resolutions ranged from 50 to 80 eV of total phonon energy. In the energy region from 2 to 7 keV, a nuclear recoil rate of 15(2) events/(kg day keV) is measured during the reactor-off period selecting events in coincidence with muon veto signals. This rate is in agreement with the cosmogenic neutron rate calculated from GEANT4 simulations. After the rejection of events in coincidence with signals in the muon veto detectors, a combined 90% C.L. limit on the nuclear recoil background of < 9 events/(kg day keV) is obtained in that energy region during the reactor-on period, which is compatible with our GEANT4 model calculation corresponding to a total rate of 5 events/(kg day keV). The sensitivity of this analysis was however found to be limited by a surface event contamination which is currently being addressed by the Ricochet Collaboration with upgraded detectors.

hep-ex

A fast plastic scintillator for low intensity proton beam monitoring

In the context of particle therapy monitoring, we are developing a gamma-ray detector to determine the ion range in vivo from the measurement of particle time-of-flight. For this application, a beam monitor capable to tag in time the incident ion with a time resolution below 235 ps FWHM (100 ps rms) is required to provide a start signal for the acquisition. We have therefore developed a dedicated detector based on a fast organic scintillator (EJ-204) of 25x25x1 mm3 coupled to four SiPM strips that allow measuring the particle incident position by scintillation light sharing. The prototype was characterised with single protons of energies between 63 and 225 MeV at the MEDICYC and ProteusONE facilities of the Antoine Lacassagne proton therapy centre in Nice. We obtained a time resolution of 120 ps FWHM at 63 MeV, and a spatial resolution of ~2 mm rms for single particles. Two identical detectors also allowed to measure the MEDICYC proton energy with 0.3% accuracy.

physics.ins-det

CONCERTO: Instrument model of Fourier transform spectroscopy, white-noise components

Modern astrophysics relies on intricate instrument setups to meet the demands of sensitivity, sky coverage, and multi-channel observations. An example is the CONCERTO project, employing advanced technology like kinetic inductance detectors and a Martin-Puplett interferometer. This instrument, installed at the APEX telescope atop the Chajnantor plateau, began commissioning observations in April 2021. Following a successful commissioning phase that concluded in June 2021, CONCERTO was offered to the scientific community for observations, with a final observing run in December 2022. CONCERTO boasts an 18.5 arcmin field of view and a spectral resolution down to 1.45 GHz in the 130-310 GHz electromagnetic band. We developed a comprehensive instrument model of CONCERTO inspired by Fourier transform spectrometry principles to optimize performance and address systematic errors. This model integrates instrument noises, subsystem characteristics, and celestial signals, leveraging both physical data and simulations. Our methodology involves delineating simulation components, executing on-sky simulations, and comparing results with real observations. The resulting instrument model is pivotal, enabling a precise error correction and enhancing the reliability of astrophysical insights obtained from observational data. In this work, we focus on the description of three white-noise noise components included in the instrument model that characterize the white-noise level: the photon, the generation-recombination, and the amplifier noises.

astro-ph.IM

CONCERTO: instrument and status

CONCERTO (CarbON CII line in post-rEionization and ReionizaTiOn) is a low-resolution Fourier transform spectrometer dedicated to the study of star-forming galaxies and clusters of galaxies in the transparent millimeter windows from the ground. It is characterized by a wide instantaneous 18.6 arcmin field of view, operates at 130-310 GHz, and was installed on the 12-meter Atacama Pathfinder Experiment (APEX) telescope at 5100 m above sea level. CONCERTO's double focal planes host two arrays of 2152 kinetic inductance detectors and represent a pioneering instrument to meet a state-of-the-art scientific challenge. This paper introduces the CONCERTO instrument and explains its status, shows the first CONCERTO spectral maps of Orion, and describes the perspectives of the project.

astro-ph.IM

A high sensitivity Cherenkov detector for Prompt Gamma Timing and Time Imaging

We recently proposed a new approach for the real-time monitoring of particle therapy treatments with the goal of achieving high sensitivities on the particle range measurement already at limited counting statistics. This method extends the Prompt Gamma (PG) timing technique to obtain the PG vertex distribution from the exclusive measurement of particle Time-Of-Flight (TOF). It was previously shown, through Monte Carlo simulation, that an original data reconstruction algorithm (Prompt Gamma Time Imaging) allows to combine the response of multiple detectors placed around the target. In this work we focus on the experimental feasibility of PGTI in Single Proton Regime (SPR) through the development of a multi-channel, Cherenkov-based PG detector with a targeted time resolution of 235 ps (FWHM): the TOF Imaging ARrAy (TIARA). The PG module that we developed is composed of a small PbF$_{2}$ crystal coupled to a silicon photoMultiplier to provide the time stamp of the PG. This prototype was tested with 63 MeV protons delivered from a cyclotron: a time resolution of 276 ps (FWHM) was obtained, resulting in a proton range sensitivity of 4 mm at 2$σ$ with the acquisition of only 600 PGs. A second prototype was also evaluated with 148 MeV protons delivered from a synchro-cyclotron obtaining a time resolution below 167 ps (FWHM) for the gamma detector. Moreover, using two identical PG modules, it was shown that a uniform sensitivity on the PG profiles would be achievable by combining the response of gamma detectors uniformly distributed around the target. This work provides the experimental proof-of-concept for the development of a high sensitivity detector that can be used to monitor particle therapy treatments and potentially act in real-time if the irradiation does not comply to treatment plan.

physics.med-ph

CONCERTO : Digital processing for finding and tuning LEKIDs

We describe the on-line algorithms developed to probe Lumped Element Kinetic Inductance Detectors (LEKID) in this paper. LEKIDs are millimeter wavelength detectors for astronomy. LEKID arrays are currently operated in different instruments as: NIKA2 at the IRAM telescope in Spain, KISS at the Teide Observatory telescope in Tenerife, and CONCERTO at the APEX 12-meter telescope in Chile. LEKIDs are superconducting microwave resonators able to detect the incoming light at millimeter wavelengths and they are well adapted for frequency multiplexing (currently up to 360 pixels on a single microwave guide). Nevertheless, their use for astronomical observations requires specific readout and acquisition systems both to deal with the instrumental and multiplexing complexity, and to adapt to the observational requirements (e.g. fast sampling rate, background variations, on-line calibration, photometric accuracy, etc). This paper presents the different steps of treatment from identifying the resonance frequency of each LEKID to the continuous automatic control of drifting LEKID resonance frequencies induced by background variations.

astro-ph.IM

CONCERTO: a breakthrough in wide field-of-view spectroscopy at millimeter wavelengths

CarbON CII line in post-rEionization and ReionizaTiOn (CONCERTO) is a low-resolution spectrometer with an instantaneous field-of-view of 18.6 arcmin, operating in the 130-310 GHz transparent atmospheric window. It is installed on the 12-meter Atacama Pathfinder Experiment (APEX) telescope at 5100 m above sea level. The Fourier transform spectrometer (FTS) contains two focal planes hosting a total of 4304 kinetic inductance detectors. The FTS interferometric pattern is recorded on the fly while continuously scanning the sky. One of the goals of CONCERTO is to characterize the large-scale structure of the Universe by observing the integrated emission from unresolved galaxies. This methodology is an innovative technique and is called line intensity mapping. In this paper, we describe the CONCERTO instrument, the effect of the vibration of the FTS beamsplitter, and the status of the CONCERTO main survey.

astro-ph.IM

Performance of CVD diamond detectors for single ion beam-tagging applications in hadrontherapy monitoring

In the context of online ion range verification in particle therapy, the CLaRyS collaboration is developing Prompt-Gamma (PG) detection systems. The originality in the CLaRyS approach is to use a beam-tagging hodoscope in coincidence with the gamma detectors to provide both temporal and spatial information of the incoming ions. The ion range sensitivity of such PG detection systems could be improved by detecting single ions with a 100 ps ($σ$) time resolution, through a quality assurance procedure at low beam intensity at the beginning of the treatment session. This work presents the investigations led to assess the performance of Chemical Vapor Deposition (CVD) diamond detectors to fulfill these requirements. A $^{90}$Sr beta source, 68 MeV protons, 95 MeV/u carbon ions and a synchrotron X-ray pulsed beam were used to measure the time resolution, single ion detection efficiency and proton counting capability of various CVD diamond samples. An offline technique, based on double-sided readout with fast current preamplifiers and used to improve the signal-to-noise ratio, is also presented. The different tests highlighted Time-Of-Flight resolutions ranging from 13 ps ($σ$) to 250 ps ($σ$), depending on the experimental conditions. The single 68 MeV proton detection efficiency of various large area polycrystalline (pCVD) samples was measured to be $>$96% using coincidence measurements with a single-crystal reference detector. Single-crystal CVD (sCVD) diamond proved to be able to count a discrete number of simultaneous protons while it was not achievable with a polycrystalline sample. Considering the results of the present study, two diamond hodoscope demonstrators are under development: one based on sCVD, and one of larger size based on pCVD. They will be used for the purpose of single ion as well as ion bunches detection, either at reduced or clinical beam intensities.

physics.ins-det