Multi-Spectral Reflection Matrix for Ultra-Fast 3D Label-Free Microscopy

Label-free microscopy exploits light scattering to obtain a three-dimensional image of biological tissues. However, light propagation is affected by aberrations and multiple scattering, which drastically degrade the image quality and limit the penetration depth. Multi-conjugate adaptive optics and time-gated matrix approaches have been developed to compensate for aberrations but the associated frame rate is extremely limited for 3D imaging. Here we develop a multi-spectral matrix approach to solve these fundamental problems. Based on a sparse illumination scheme and an interferometric measurement of the reflected wave-field at multiple wavelengths, the focusing process can be optimized in post-processing for any voxel by addressing independently each frequency component of the reflection matrix. A proof-of-concept experiment demonstrates the three-dimensional image of an opaque human cornea over a 0.1 mm$^3$-field-of-view at a 290 nm-resolution and a 1 Hz-frame rate. This work paves the way towards a fully-digital microscope allowing real-time, in-vivo, quantitative and deep inspection of tissues.

physics.optics

Comparative analysis of full-field OCT and optical transmission tomography

This work compares two tomographic imaging technologies, time-domain full-field optical coherence tomography (FFOCT) working in reflection and optical transmission tomography (OTT), using a new optical setup that combines both. We show that, due to forward-scattering properties, the axial sectioning and contrast in OTT can be optimized by tuning illumination. The influence of sample scattering and thickness are discussed. We illustrate the comparison of the two methods in static (morphology) and dynamic (metabolic contrast) regimes using cell cultures, tissues and entire organisms emphasizing the advantages of both approaches.

physics.optics

Label free optical transmission tomography for biosystems: Intracellular structures and dynamics

There is an increasing need for label free methods that could reveal intracellular structures and dynamics. In this context, we develop a new optical tomography method working in transmission - Full-field optical transmission tomography (FF-OTT). The method can measure the forward scattering signals and reveal the metabolic time-dependent signals in living cells. FF-OTT is a common path interferometer taking advantage of the Gouy phase shift - a π phase shift that the light wave experiences around the focus. By modulating position of the focus one can alter the phase of the scattered light. Demodulation of images with different phases rejects the background and enhances the light from the depth-of-focus, thus producing an optical section. We test FF-OTT by imaging single-cell diatoms and ex vivo biological samples. In fresh samples, we show that the intracellular motions create visible intensity fluctuations in FF-OTT so that the method is able to reveal a metabolic dynamic contrast. FF-OTT was found to be an efficient label free technique that can be readily implemented thanks to a robust common-path speckle-free interferometer design using an incoherent light source.

physics.optics

Non invasive live imaging of a novel retinal pigment epithelium stress model with Dynamic Full-Field Optical Coherence Tomography

Retinal degenerative diseases lead to the blindness of millions of people around the world. In case of age-related macular degeneration (AMD), the atrophy of retinal pigment epithelium (RPE) precedes neural dystrophy. But as crucial as understanding both healthy and pathological RPE cell physiology is for those diseases, no current technique allows subcellular in vivo or in vitro live observation of this critical cell layer. To fill this gap, we propose dynamic full-field OCT (D-FFOCT) as a candidate for live observation of in vitro RPE phenotype. In this way, we monitored primary porcine and human stem cell-derived RPE cells in stress model conditions by performing scratch assays. In this study, we quantified wound healing parameters on the stressed RPE, and observed different cell phenotypes, displayed by the D-FFOCT signal. In order to decipher the subcellular contributions to these dynamic profiles, we performed immunohistochemistry to identify which organelles generate the signal and found mitochondria to be the main contributor to D-FFOCT contrast. Altogether, D-FFOCT appears to be an innovative method to follow degenerative disease evolution and could be an appreciated method in the future for live patient diagnostics and to direct treatment choice.

physics.bio-ph

Adaptive-glasses wavefront sensorless full-field OCT for high-resolution retinal imaging over a wide field-of-view

The highest three-dimensional (3D) resolution possible in in-vivo retinal imaging is achieved by combining optical coherence tomography (OCT) and adaptive optics (AO). However, this combination brings important limitations, such as small field-of-view and complex, cumbersome systems, preventing so far the translation of this technology from the research lab to clinics. In this Letter, we introduce an approach that avoids these limitations by using a multi-actuator adaptive lens just in front of the eye, in a technique we call the adaptive-glasses wavefront sensorless approach. We implemented this approach on our compact full-field OCT (FFOCT) retinal imager without increasing its footprint or optical complexity. The correction of ocular aberrations through the adaptive-glasses approach increased the FFOCT signal-to-noise ratio and enabled us to image different retinal layers with a 3D cellular resolution in a 5° $\times$ 5° field-of-view, without apparent anisoplanatism.

physics.med-ph

Curved-Full-Field OCT for high-resolution imaging of living human retina over a large field-of-view

Allying high-resolution with a large field-of-view (FOV) is of great importance in the fields of biology and medicine, but particularly challenging when imaging non-flat living samples such as the human retina. Indeed, high-resolution is normally achieved with adaptive optics (AO) and scanning methods, which considerably reduce the useful FOV and increase the system complexity. An alternative technique is time-domain Full-Field Optical Coherence Tomography (FF-OCT), which has already shown its potential for in-vivo high-resolution retinal imaging. Here, we introduce curved-field FF-OCT, capable of matching the coherence gate geometry to the sample curvature, thus achieving a larger FOV than previously possible. Using this instrument, we obtained high-resolution images of living human photoreceptors close to the foveal center without AO and with a 1 mm x 1 mm FOV in a single shot. This novel advance enables the extraction of photoreceptor-based biomarkers with ease and spatiotemporal monitoring of individual photoreceptors. We compare our findings with AO-assisted ophthalmoscopes, highlighting the potential of FF-OCT, as a relatively simple, compact and low-cost system, to become a routine clinical imaging technique.

physics.med-ph

Dynamic full-field optical coherence tomography: 3D live-imaging of retinal organoids

Optical coherence tomography offers astounding opportunities to image the complex structure of living tissue, but lacks functional information. We present dynamic full-field optical coherence tomography to image living human induced pluripotent stem cell-derived retinal organoids non-invasively. Colored images with an endogenous contrast linked to organelle motility are generated, with sub-micrometer spatial resolution and millisecond temporal resolution, opening an avenue to identify specific cell types in living tissue via their function.

physics.bio-ph

Improving Photoacoustic-guided Focusing in Scattering Media by Spectrally Filtered Detection

We experimentally and numerically study the potential of photoacoustic-guiding for light focusing through scattering samples via wavefront-shaping and iterative optimization. We experimentally demonstrate that the focusing efficiency on an extended absorber can be improved by iterative optimization of the high frequency components of the broadband photoacoustic signal detected with a spherically focused transducer. We demonstrate more than 8-fold increase in the photoacoustic signal generated by a 30 microns wire using a narrow frequency band around 60MHz. We numerically confirm that such optimization leads to a smaller optical focus than using the low frequency content of the photoacoustic feedback.

physics.optics

Imaging of non tumorous and tumorous human brain tissue with full-field optical coherence tomography

A prospective study was performed on neurosurgical samples from 18 patients to evaluate the use of Full-Field Optical Coherence Tomography (FF-OCT) in brain tumor diagnosis. FF-OCT captures en face slices of tissue samples at 1\mum resolution in 3D with a typical 200\mum imaging depth. A 1cm2 specimen is scanned at a single depth and processed in about 5 minutes. This rapid imaging process is non-invasive and 30 requires neither contrast agent injection nor tissue preparation, which makes it particularly well suited to medical imaging applications. Temporal chronic epileptic parenchyma and brain tumors such as meningiomas, low- grade and high-grade gliomas, and choroid plexus papilloma were imaged. A subpopulation of neurons, myelin fibers and CNS vasculature were clearly identified. Cortex could be discriminated from white matter, but individual glial cells as astrocytes (normal or reactive) or oligodendrocytes were not observable. This study reports for the first time on the feasibility of using FF-OCT in a real-time manner as a label-free non-invasive imaging technique in an intra-operative neurosurgical clinical setting to assess tumorous glial and epileptic margins.

physics.med-ph

Large Field, High Resolution Full Field Optical Coherence Tomography: A Pre-clinical study of human breast tissue and cancer assessment

We present a benchmark pilot study in which high-resolution Full-Field Optical Coherence Tomography (FF-OCT) is used to image human breast tissue and is evaluated to assess its ability to aid the pathologist's management of intra-operative diagnoses. Our aim included evaluating the safety of FF-OCT on human tissue and determining the concordance between the images obtained with routinely prepared histopathological material. The compact device used for this study provides a 2 μm-lateral and a 1 μm-axial resolution, and is able to scan a 1.5cm^2 specimen in about 7 minutes. 75 breast specimens obtained from 22 patients have been imaged. Because the contrast in the images is generated by endogenous tissue components, no biological, contrast agents or specimen preparation is required. We characterized the major architectural features and tissue structures of benign breast tissue, including adipocytes, fibrous stroma, lobules and ducts. We subsequently characterized features resulting from their pathological modification and developed a decision tree for diagnosis. Two breast pathologists applied these criteria, resulting in a demonstrable ability to distinguish between normal or benign tissue, in situ and invasive carcinomas using FF-OCT images, with a sensitivity of 97% and 90%, respectively, and specificity of 74% and 77% respectfully. FF-OCT shows great potential for the evaluation of human tissue and its characterization as normal/benign vs. lesional, for numerous ex-vivo clinical use-cases. Its high imaging accuracy for in-situ and invasive carcinoma paves the way for applications where a fast architectural assessment could improve the core needle biopsy workflow, tumor margin assessments, and provides quality assurance for tissue acquired for clinical care and research.

physics.optics

Detection of the tagged or untagged photons in acousto-optic imaging of thick highly scattering media by photorefractive adaptive holography

We propose an original adaptive wavefront holographic setup based on the photorefractive effect (PR), to make real-time measurements of acousto-optic signals in thick scattering media, with a high flux collection at high rates for breast tumor detection. We describe here our present state of art and understanding on the problem of breast imaging with PR detection of the acousto-optic signal.

physics.optics

Optical 3D-storage in sol-gel materials with a reading by Optical Coherence Tomography-technique

We report on the recording of 3D optical memories in sol-gel materials by using a non-linear absorption effect. This effect induces a local change of the optical properties of the material which is read and quantified with a high resolution full-field Optical Coherence Tomography setup. It is the first time that this technique is used for this purpose. Data recording was performed by focused picosecond (ps) single-pulse irradiation at 1064 nm with energy densities of 10 and 33 J/cm2 per pulse.