Searcharxiv⌕ Search

arXiv subjects

Congzhan Liu

Publications and source records attributed to Congzhan Liu.

25 records · Page 2Linked to original sources

The removal method and generation mechanism of spikes in Insight-HXMT/HE telescope

Spikes are some obvious sharp increases that appear on the raw light curves of High Energy X-ray telescope(HE) onboard Insight-HXMT, which could have influences on the data products like energy and power spectra. They are considered to be fake triggers generated by large signals. In this paper, we study the characteristic of the spikes and propose two methods to remove spikes from the raw data. According to the different influences on energy and power spectra, the best parameters for removing the spikes is selected and used in the Insight-HXMT data analysis software. The generation mechanism of spikes is also studied using the backup HE detectors on ground and the spikes can be reduced by the electronic design.

astro-ph.IM↗

In-orbit timing calibration of the Insight-Hard X-ray Modulation Telescope

We describe the timing system and the timing calibration results of the three payloads on-board the Insight-Hard X-ray Modulation Telescope (Insight-HXMT). These three payloads are the High Energy X-ray telescope (HE, 20-250 keV), the Medium Energy X-ray telescope (ME, 5-30 keV) and the low Energy X-ray telescope (LE, 1-10 keV). We present a method to correct the temperature-dependent period response and the long-term variation of the on-board crystal oscillator, especially for ME that does not carry a temperature-compensated crystal oscillator. The time of arrivals (ToAs) of the Crab pulsar are measured to evaluate the accuracy of the timing system. As the ephemeris of the Crab pulsar given by Jodrell Bank observatory has systematic errors around 40 μs (Rots et al. 2014), we use the quasi-simultaneous observations of the X-ray Timing Instrument (XTI) on-board the Neutron star Interior Composition Explorer (NICER) to produce the Crab ephemerides and to verify the timing system of Insight-HXMT. The energy-dependent ToAs' offsets relative to the NICER measurements including physical and instrumental origins are about 24.7μs, 10.1μs and 864.7μs, and the systematic errors of the timing system are determined as 12.1μs, 8.6μs, and 15.8μs, for HE, ME and LE respectively.

astro-ph.HE↗

Insight-HXMT observations of jet-like corona in a black hole X-ray binary MAXI J1820+070

A black hole X-ray binary produces hard X-ray radiation from its corona and disk when the accreting matter heats up. During an outburst, the disk and corona co-evolves with each other. However, such an evolution is still unclear in both its geometry and dynamics. Here we report the unusual decrease of the reflection fraction in MAXI J1820+070, which is the ratio of the coronal intensity illuminating the disk to the coronal intensity reaching the observer, as the corona is observed to contrast during the decay phase. We postulate a jet-like corona model, in which the corona can be understood as a standing shock where the material flowing through. In this dynamical scenario, the decrease of the reflection fraction is a signature of the corona's bulk velocity. Our findings suggest that as the corona is observed to get closer to the black hole, the coronal material might be outflowing faster.

astro-ph.HE↗

Design and Calibration of the High Energy Particle Monitor onboard the Insight-HXMT

Three high energy particle monitors (HPMs) employed onboard the Hard X-ray Modulation Telescope Insight-HXMT) can detect the charged particles from South Atlantic Anomaly (SAA) and hence provide the alert trigger for switch-on/off of the main detectors. Here a typical design of HPM with high stability and reliability is adopted by taking a plastic scintillator coupled with a small photomultiplier tube (PMT). The window threshold of HPM is designed as 1 MeV and 20 MeV for the incident electron and proton, respectively. Before the launch of Insight-HXMT, we performed in details the ground calibration of HPM. The measured energy response and its dependence on temperature are taken as essential input of Geant4 simulation for estimating the HPM count rate given with an incident particle energy spectrum. This serves as a guidance for choosing a reasonable working range of the PMT high voltage once the real SAA count rate is measured by HPM in orbit. So far the three HPMs have been working in orbit for more than two years. Apart from providing reliable alert trigger, the HPMs data are used as well to map the SAA region.

physics.ins-det↗

In-flight calibration of the Insight-Hard X-ray Modulation Telescope

We present the calibration of the Insight-Hard X-ray Modulation Telescope (Insight-HXMT) X-ray satellite, which can be used to perform timing and spectral studies of bright X-ray sources. Insight-HXMT carries three main payloads onboard: the High Energy X-ray telescope (HE), the Medium Energy X-ray telescope (ME) and the Low Energy X-ray telescope (LE). In orbit, the radioactive sources, activated lines, the fluorescence lines and celestial sources are used to calibrate the energy scale and energy resolution of the payloads. The Crab nebular is adopted as the primary effective area calibrator and empirical functions are constructed to modify the simulated effective areas of the three payloads respectively. The systematic errors of HE, compared to the model of the Crab nebular, are less than 2% in 28--120 keV and 2%--10% above 120 keV. The systematic errors of ME are less than 1.5% in 10--35 keV. The systematic errors of LE are less than 1% in 1--7 keV except the Si K--edge (1.839 keV, up to 1.5%) and less than 2% in 7--10 keV.

astro-ph.IM↗

Insight-HXMT observations of Swift J0243.6+6124 during its 2017-2018 outburst

The recently discovered neutron star transient Swift J0243.6+6124 has been monitored by {\it the Hard X-ray Modulation Telescope} ({\it Insight-\rm HXMT). Based on the obtained data, we investigate the broadband spectrum of the source throughout the outburst. We estimate the broadband flux of the source and search for possible cyclotron line in the broadband spectrum. No evidence of line-like features is, however, found up to $\rm 150~keV$. In the absence of any cyclotron line in its energy spectrum, we estimate the magnetic field of the source based on the observed spin evolution of the neutron star by applying two accretion torque models. In both cases, we get consistent results with $B\rm \sim 10^{13}~G$, $D\rm \sim 6~kpc$ and peak luminosity of $\rm >10^{39}~erg~s^{-1}$ which makes the source the first Galactic ultraluminous X-ray source hosting a neutron star.

astro-ph.HE↗

A novel analog power supply for gain control of the Multi-Pixel Photon Counter (MPPC)

Silicon Photo-Multipliers (SiPM) are regarded as novel photo-detectors to replace conventional Photo-Multiplier Tubes (PMTs). However, the breakdown voltage dependence on the ambient temperature results in a gain variation of $\sim$3$\% /^{\circ} \mathrm C$. This severely limits the application of this device in experiments with wide range of operating temperature, especially in space missions. An experimental setup was established to investigate the temperature and bias voltage dependence of gain for the Multi-Pixel Photon Counter (MPPC). The gain and breakdown voltage dependence on operating temperature of an MPPC can be approximated by a linear function, which is similar to the behavior of a zener diode. The measured temperature coefficient of the breakdown voltage is $(59.4 \pm 0.4$ mV)$/^{\circ} \mathrm C$. According to this fact, an analog power supply based on two zener diodes and an operational amplifier was designed with a positive temperature coefficient. The measured temperature dependence for the designed power supply is between 63.65 to 64.61~mV/$^{\circ} \mathrm C$ at different output voltages. The designed power supply can bias the MPPC at an over-voltage with a temperature variation of $\sim$ 5~mV$/^{\circ} \mathrm C$. The gain variation of the MPPC biased at over-voltage of 2~V was reduced from 2.8$\% /^{\circ} \mathrm C$ to 0.3$\% /^{\circ} \mathrm C$ when biased the MPPC with the designed power supply for gain control. Detailed design and performance of the analog power supply in the temperature range from -42.7$^{\circ}\mathrm{C}$ to 20.9$^{\circ}\mathrm{C}$ will be discussed in this paper.

astro-ph.IM↗