arXiv · 1911.01594
Design and Calibration of the High Energy Particle Monitor onboard the Insight-HXMT
Abstract
Three high energy particle monitors (HPMs) employed onboard the Hard X-ray Modulation Telescope Insight-HXMT) can detect the charged particles from South Atlantic Anomaly (SAA) and hence provide the alert trigger for switch-on/off of the main detectors. Here a typical design of HPM with high stability and reliability is adopted by taking a plastic scintillator coupled with a small photomultiplier tube (PMT). The window threshold of HPM is designed as 1 MeV and 20 MeV for the incident electron and proton, respectively. Before the launch of Insight-HXMT, we performed in details the ground calibration of HPM. The measured energy response and its dependence on temperature are taken as essential input of Geant4 simulation for estimating the HPM count rate given with an incident particle energy spectrum. This serves as a guidance for choosing a reasonable working range of the PMT high voltage once the real SAA count rate is measured by HPM in orbit. So far the three HPMs have been working in orbit for more than two years. Apart from providing reliable alert trigger, the HPMs data are used as well to map the SAA region.
Explore related subjects
Keep this discovery
Xuefeng Lu, Congzhan Liu, Xiaobo Li, Yifei Zhang, Zhengwei Li, Aimei Zhang, Shuang-Nan Zhang, Shu Zhang, Gang Li, Xufang Li, Fangjun Lu, Yupeng Xu, Zhi Chang, Fan Zhang. 2019-11-05. Design and Calibration of the High Energy Particle Monitor onboard the Insight-HXMT. https://arxiv.org/abs/1911.01594
Cite the original work for its findings. Save a collection to share your selection of sources.