SearcharxivSearch

arXiv subjects

D. Bishop

Publications and source records attributed to D. Bishop.

12 recordsLinked to original sources

Innovative Oxide Transistor Satisfying Performance and Reliability Simultaneously by Understanding of Physics and Materials Properties

Guided by a comprehensive analysis of accumulation mode transistor physics and oxide semiconductor materials properties, we demonstrate an innovative oxide semiconductor transistor structure and process flow that break the constraint between performance and reliability observed in conventional InGaZnO4 (IGZO) transistors. The newly proposed 10 nm innovative IGZO transistor features high on-current, high extrinsic mobility (20 cm2V-1s-1), near-zero hysteresis, and only 15 mV Vt shift after positive-bias-stress (PBS) of 3 MV/cm stress for 1000s at room temperature.

cond-mat.mtrl-sci

Decay Spectroscopy of $^{160}$Eu: Quasiparticle Configurations of Excited States and Structure of $K^\pi$=$4^+$ Band-heads in $^{160}$Gd

\noindent \textbf{Background:} Detailed spectroscopy of neutron-rich, heavy, deformed nuclei is of broad interest for nuclear astrophysics and nuclear structure. Nuclei in the r-process path and following freeze-out region impact the resulting r-process abundance distribution, and the structure of nuclei midshell in both proton and neutron number helps to understand the evolution of subshell gaps and large deformation in these nuclei. \noindent \textbf{Purpose:} To improve the understanding of the nuclear structure of $^{160}$Gd, specifically the $K^\pi$=$4^+$ bands, as well as study the $\beta$-decay of $^{160}$Eu into $^{160}$Gd. \noindent \textbf{Methods:} High-statistics decay spectroscopy of $^{160}$Gd resulting from the $\beta$-decay of $^{160}$Eu was collected using the GRIFFIN spectrometer at the TRIUMF-ISAC facility. \noindent \textbf{Results:} Two new excited states and ten new transitions were observed in $^{160}$Gd. The $\beta$-decaying half-lives of the low- and high-spin isomer in $^{160}$Eu were determined, and the low-spin state's half-life was measured to be $t_{1/2}=26.0(8)$~s, $\sim$16\% shorter than previous measurements. Lifetimes of the two $K^\pi$=$4^+$ band-heads in $^{160}$Gd were measured for the first time, as well as $\gamma$-$\gamma$ angular correlations and mixing ratios of intense transitions out of those band-heads. \noindent \textbf{Conclusions:} Lifetimes and mixing ratios suggest that the hexadecapole phonon model of the $K^\pi$=$4^+$ band-heads in $^{160}$Gd is preferred over a simple two-state strong mixing scenario, although further theoretical calculations are needed to fully understand these states. Additionally, the 1999.0 keV state in $^{160}$Gd heavily populated in $\beta$-decay is shown to have positive parity, which raises questions regarding the structure of the high-spin $\beta$-decaying state in $^{160}$Eu.

nucl-ex

Mechanical Ventilator Milano (MVM): A Novel Mechanical Ventilator Designed for Mass Scale Production in Response to the COVID-19 Pandemic

Presented here is the design of the Mechanical Ventilator Milano (MVM), a novel mechanical ventilator designed for rapid mass production in response to the COVID-19 pandemic to address the urgent shortage of intensive therapy ventilators in many countries, and the growing difficulty in procuring these devices through normal supply chains across borders. This ventilator is an electro-mechanical equivalent of the old and reliable Manley Ventilator, and is able to operate in both pressure-controlled and pressure-supported ventilation modes. MVM is optimized for the COVID-19 emergency, thanks to the collaboration with medical doctors in the front line. MVM is designed for large-scale production in a short amount of time and at a limited cost, as it relays on off-the-shelf components, readily available worldwide. Operation of the MVM requires only a source of compressed oxygen (or compressed medical air) and electrical power. Initial tests of a prototype device with a breathing simulator are also presented. Further tests and developments are underway. At this stage the MVM is not yet a certified medical device but certification is in progress.

physics.med-ph

In-situ characterization of the Hamamatsu R5912-HQE photomultiplier tubes used in the DEAP-3600 experiment

The Hamamatsu R5912-HQE photomultiplier-tube (PMT) is a novel high-quantum efficiency PMT. It is currently used in the DEAP-3600 dark matter detector and is of significant interest for future dark matter and neutrino experiments where high signal yields are needed. We report on the methods developed for in-situ characterization and monitoring of DEAP's 255 R5912-HQE PMTs. This includes a detailed discussion of typical measured single-photoelectron charge distributions, correlated noise (afterpulsing), dark noise, double, and late pulsing characteristics. The characterization is performed during the detector commissioning phase using laser light injected through a light diffusing sphere and during normal detector operation using LED light injected through optical fibres.

physics.ins-det

The GRIFFIN Facility for Decay-Spectroscopy Studies at TRIUMF-ISAC

Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei, GRIFFIN, is a new high-efficiency $γ$-ray spectrometer designed for use in decay spectroscopy experiments with low-energy radioactive ion beams provided by TRIUMF's Isotope Separator and Accelerator (ISAC-I) facility. GRIFFIN is composed of sixteen Compton-suppressed large-volume clover-type high-purity germanium (HPGe) $γ$-ray detectors combined with a suite of ancillary detection systems and coupled to a custom digital data acquisition system. The infrastructure and detectors of the spectrometer as well as the performance characteristics and the analysis techniques applied to the experimental data are described.

physics.ins-det

First results from the DEAP-3600 dark matter search with argon at SNOLAB

This paper reports the first results of a direct dark matter search with the DEAP-3600 single-phase liquid argon (LAr) detector. The experiment was performed 2 km underground at SNOLAB (Sudbury, Canada) utilizing a large target mass, with the LAr target contained in a spherical acrylic vessel of 3600 kg capacity. The LAr is viewed by an array of PMTs, which would register scintillation light produced by rare nuclear recoil signals induced by dark matter particle scattering. An analysis of 4.44 live days (fiducial exposure of 9.87 tonne-days) of data taken with the nearly full detector during the initial filling phase demonstrates the detector performance and the best electronic recoil rejection using pulse-shape discrimination in argon, with leakage $<1.2\times 10^{-7}$ (90% C.L.) between 16 and 33 keV$_{ee}$. No candidate signal events are observed, which results in the leading limit on WIMP-nucleon spin-independent cross section on argon, $<1.2\times 10^{-44}$ cm$^2$ for a 100 GeV/c$^2$ WIMP mass (90% C.L.).

astro-ph.CO

In-beam internal conversion electron spectroscopy with the SPICE detector

The SPectrometer for Internal Conversion Electrons (SPICE) has been commissioned for use in conjunction with the TIGRESS $γ$-ray spectrometer at TRIUMF's ISAC-II facility. SPICE features a permanent rare-earth magnetic lens to collect and direct internal conversion electrons emitted from nuclear reactions to a thick, highly segmented, lithium-drifted silicon detector. This arrangement, combined with TIGRESS, enables in-beam $γ$-ray and internal conversion electron spectroscopy to be performed with stable and radioactive ion beams. Technical aspects of the device, capabilities, and initial performance are presented.

physics.ins-det

Design and Construction of the DEAP-3600 Dark Matter Detector

The Dark matter Experiment using Argon Pulse-shape discrimination (DEAP) has been designed for a direct detection search for particle dark matter using a single-phase liquid argon target. The projected cross section sensitivity for DEAP-3600 to the spin-independent scattering of Weakly Interacting Massive Particles (WIMPs) on nucleons is $10^{-46}~\rm{cm}^{2}$ for a 100 GeV/$c^2$ WIMP mass with a fiducial exposure of 3 tonne-years. This paper describes the physical properties and construction of the DEAP-3600 detector.

astro-ph.IM

The GRIFFIN Data Acquisition System

Gamma-Ray Infrastructure For Fundamental Investigations of Nuclei, GRIFFIN, is a new experimental facility for radioactive decay studies at the TRIUMF-ISAC laboratory. This article describes the details of the custom designed GRIFFIN digital data acquisition system. The features of the system that will enable high-precision half-life and branching ratio measurements with levels of uncertainty better than 0.05% are described. The system has demonstrated the ability to effectively collect signals from High-purity germanium crystals at counting rates up to 50kHz while maintaining good energy resolution, detection efficiency and spectral quality.

physics.ins-det

A large Bradbury Nielsen ion gate with flexible wire spacing based on photo-etched stainless steel grids and its characterization applying symmetric and asymmetric potentials

Bradbury Nielsen gates are well known devices used to switch ion beams and are typically applied in mass or mobility spectrometers for separating beam constituents by their different flight or drift times. A Bradbury Nielsen gate consists of two interleaved sets of electrodes. If two voltages of the same amplitude but opposite polarity are applied the gate is closed, and for identical (zero) potential the gate is open. Whereas former realizations of the device employ actual wires resulting in difficulties with winding, fixing and tensioning them, our approach is to use two grids photo-etched from a metallic foil. This design allows for simplified construction of gates covering large beam sizes up to at least 900\,mm$^2$ with variable wire spacing down to 250\,\textmu m. By changing the grids the wire spacing can be varied easily. A gate of this design was installed and systematically tested at TRIUMF's ion trap facility, TITAN, for use with radioactive beams to separate ions with different mass-to-charge ratios by their time-of-flight.

physics.ins-det

The T2K Experiment

The T2K experiment is a long-baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle θ_{13} by observing ν_e appearance in a ν_μ beam. It also aims to make a precision measurement of the known oscillation parameters, Δm^{2}_{23} and sin^{2} 2θ_{23}, via ν_μ disappearance studies. Other goals of the experiment include various neutrino cross section measurements and sterile neutrino searches. The experiment uses an intense proton beam generated by the J-PARC accelerator in Tokai, Japan, and is composed of a neutrino beamline, a near detector complex (ND280), and a far detector (Super-Kamiokande) located 295 km away from J-PARC. This paper provides a comprehensive review of the instrumentation aspect of the T2K experiment and a summary of the vital information for each subsystem.

physics.ins-det

Status Update on the ISAC Control System

Implementation and commissioning of the EPICS based control system for the ISAC radioactive beam facility was completed. The target ion source, mass separator, and low-energy beam-lines started beam production for experiments. In parallel, controls for the accelerator system, a radio-frequency quadrupole followed by a drift-tube linac, and several high-energy beam-lines were implemented and commissioned. The number of controlled devices more than doubled since the last report. An overview of relational database usage, software engineering and quality control methods used will be given.

physics.acc-ph