Searcharxiv⌕ Search

arXiv subjects

D. Kalita

Publications and source records attributed to D. Kalita.

23 records · Page 2Linked to original sources

Measurements of branching fractions of $Λ_c^+ \to Σ^+ η$ and $Λ_c^+ \to Σ^+ η'$ and asymmetry parameters of $Λ_c^+ \to Σ^+ π^0$, $Λ_c^+ \to Σ^+ η$, and $Λ_c^+ \to Σ^+ η'$

We report a study of $Λ_c^+ \to Σ^+ π^0$, $Λ_c^+ \to Σ^+ η$, and $Λ_c^+ \to Σ^+ η'$ using the data sample corresponding to an integrated luminosity of 980 $\rm fb^{-1}$ collected with the Belle detector at the KEKB asymmetric-energy $e^+e^-$ collider. The branching fractions relative to $Λ_c^+ \to Σ^+ π^0$ are measured as: $\mathcal{B}_{Λ_c^+ \to Σ^+ η}/\mathcal{B}_{Λ_c^+ \to Σ^+ π^0}=0.25 \pm 0.03 \pm 0.01$ and $\mathcal{B}_{Λ_c^+ \to Σ^+ η'}/\mathcal{B}_{Λ_c^+ \to Σ^+ π^0}=0.33 \pm 0.06 \pm 0.02$. Using $\mathcal{B}_{Λ_c^+ \to Σ^+ π^0}=(1.25 \pm 0.10)\%$, we obtain $\mathcal{B}_{Λ_c^+ \to Σ^+ η}=(3.14 \pm 0.35 \pm 0.11 \pm 0.25)\times10^{-3}$ and $\mathcal{B}_{Λ_c^+ \to Σ^+ η'}=(4.16 \pm 0.75 \pm 0.21 \pm 0.33)\times10^{-3}$. Here the uncertainties are statistical, systematic, and from $\mathcal{B}_{Λ_c^+ \to Σ^+ π^0}$, respectively. The ratio of the branching fraction of $Λ_c^+ \to Σ^+ η'$ with respect to that of $Λ_c^+ \to Σ^+ η$ is measured to be $\mathcal{B}_{Λ_c^+ \to Σ^+ η'}/\mathcal{B}_{Λ_c^+ \to Σ^+ η}=1.34 \pm 0.28 \pm 0.06$. We update the asymmetry parameter of $Λ_c^+ \to Σ^+ π^0$, $α_{Σ^+ π^0} = -0.48 \pm 0.02 \pm 0.02$, with a considerably improved precision. The asymmetry parameters of $Λ_c^+ \to Σ^+ η$ and $Λ_c^+ \to Σ^+ η'$ are measured to be $α_{Σ^+ η} = -0.99 \pm 0.03 \pm 0.05$ and $α_{Σ^+ η'} = -0.46 \pm 0.06 \pm 0.03$ for the first time.

hep-ex↗

Measurement of the branching fractions for Cabibbo-suppressed decays $D^{+}\to K^{+} K^{-}π^{+}π^{0}$ and $D_{(s)}^{+}\to K^{+}π^{-}π^{+}π^{0}$ at Belle

We present measurements of the branching fractions for the singly Cabibbo-suppressed decays $D^+\to K^{+}K^{-}π^{+}π^{0}$ and $D_s^{+}\to K^{+}π^{-}π^{+}π^{0}$, and the doubly Cabibbo-suppressed decay $D^{+}\to K^{+}π^{-}π^{+}π^{0}$, based on 980 ${\rm fb}^{-1}$ of data recorded by the Belle experiment at the KEKB $e^{+}e^{-}$ collider. We measure these modes relative to the Cabibbo-favored modes $D^{+}\to K^{-}π^{+}π^{+}π^{0}$ and $D_s^{+}\to K^{+}K^{-}π^{+}π^{0}$. Our results for the ratios of branching fractions are $B(D^{+}\to K^{+}K^{-}π^{+}π^{0})/B(D^{+}\to K^{-}π^{+}π^{+}π^{0}) = (11.32 \pm 0.13 \pm 0.26)\%$, $B(D^{+}\to K^{+}π^{-}π^{+}π^{0})/B(D^{+}\to K^{-}π^{+}π^{+}π^{0}) = (1.68 \pm 0.11\pm 0.03)\%$, and $B(D_s^{+}\to K^{+}π^{-}π^{+}π^{0})/B(D_s^{+}\to K^{+}K^{-}π^{+}π^{0}) = (17.13 \pm 0.62 \pm 0.51)\%$, where the uncertainties are statistical and systematic, respectively. The second value corresponds to $(5.83\pm 0.42)\times\tan^4θ_C$, where $θ_C$ is the Cabibbo angle; this value is larger than other measured ratios of branching fractions for a doubly Cabibbo-suppressed charm decay to a Cabibbo-favored decay. Multiplying these results by world average values for $B(D^{+}\to K^{-}π^{+}π^{+}π^{0})$ and $B(D_s^{+}\to K^{+}K^{-}π^{+}π^{0})$ yields $B(D^{+}\to K^{+}K^{-}π^{+}π^{0})= (7.08\pm 0.08\pm 0.16\pm 0.20)\times10^{-3}$, $B(D^{+}\to K^{+}π^{-}π^{+}π^{0})= (1.05\pm 0.07\pm 0.02\pm 0.03)\times10^{-3}$, and $B(D_s^{+}\to K^{+}π^{-}π^{+}π^{0}) = (9.44\pm 0.34\pm 0.28\pm 0.32)\times10^{-3}$, where the third uncertainty is due to the branching fraction of the normalization mode. The first two results are consistent with, but more precise than, the current world averages. The last result is the first measurement of this branching fraction.

hep-ex↗

Search for the decay $B_s^0 \to η^\prime K_S^0$

We report the results of the first search for the decay $B_s^0 \to η^\prime K_S^0$ using $121.4\,{\rm fb}^{-1}$ of data collected at the $Υ(5S)$ resonance with the Belle detector at the KEKB asymmetric-energy $e^+ e^-$ collider. We observe no signal and set a 90\% confidence-level upper limit of $8.16 \times 10^{-6}$ on the $B_s^0 \to η^\prime K_S^0$ branching fraction.

hep-ex↗

Nanofaceting as a stamp for periodic graphene charge carrier modulations

The exceptional electronic properties of monoatomic thin graphene sheets triggered numerous original transport concepts, pushing quantum physics into the realm of device technology for electronics, optoelectronics and thermoelectrics. At the conceptual pivot point is the particular twodimensional massless Dirac fermion character of graphene charge carriers and its volitional modification by intrinsic or extrinsic means. Here, interfaces between different electronic and structural graphene modifications promise exciting physics and functionality, in particular when fabricated with atomic precision. In this study we show that quasiperiodic modulations of doping levels can be imprinted down to the nanoscale in monolayer graphene sheets. Vicinal copper surfaces allow to alternate graphene carrier densities by several 10^13 carriers per cm^2 along a specific copper high-symmetry direction. The process is triggered by a self-assembled copper faceting process during high-temperature graphene chemical vapor deposition, which defines interfaces between different graphene doping levels at the atomic level.

cond-mat.mtrl-sci↗

Interplay between Raman shift and thermal expansion in graphene: temperature-dependent measurements and analysis of substrate corrections

Measurements and calculations have shown significant disagreement regarding the sign and variations of the thermal expansion coefficient (TEC) of graphene $α(T)$. Here we report dedicated Raman scattering experiments conducted for graphene monolayers deposited on silicon nitride substrates and over the broad temperature range 150--900~K. The relation between those measurements for the G band and the graphene TEC, which involves correcting the measured signal for the mismatch contribution of the substrate, is analyzed based on various theoretical candidates for $α(T)$. Contrary to calculations in the quasiharmonic approximation, a many-body potential reparametrized for graphene correctly reproduces experimental data. These results indicate that the TEC is more likely to be positive above room temperature.

cond-mat.mes-hall↗