SearcharxivSearch

arXiv subjects

D. M. Paganin

Publications and source records attributed to D. M. Paganin.

At least 19 recordsLinked to original sources

On imaging capabilities of the Imaging and Medical beamline at the Australian Synchrotron

Several propagation-based and analyser-based X-ray phase-contrast imaging experiments with over 100 m between the imaged objects and the detector were carried out at the Imaging and Medical beamline (IMBL) of the Australian Synchrotron. These experiments were aimed at characterization of possible phase-contrast imaging setups at IMBL. Effects of the beam divergence, polychromaticity and X-ray source size on the contrast and spatial resolution of images were evaluated quantitatively in different imaging scenarios. The results of this work will be used for improving the existing and developing new imaging capabilities at the beamline. Applications to X-ray phase-contrast tomography of biomedical samples, particularly for medical breast cancer imaging, are briefly discussed.

physics.optics

Signal-to-noise and spatial resolution in in-line imaging. 3. Optimization using a simple model

The problem of optimization of propagation-based phase-contrast imaging setups is considered in the case of projection X-ray imaging and three-dimensional tomography with phase retrieval. For two-dimensional imaging, a simple model for a homogeneous edge feature embedded in a bulk sample is used to obtain analytical expressions for the image intensity. This model allows for explicit optimization of the geometrical parameters of the imaging setup and the choice of X-ray energy that maximizes the image contrast or the contrast-to-noise ratio. We also consider the question of optimization of the biomedical X-ray imaging quality characteristic which balances the contrast-to-noise against the spatial resolution and the radiation dose. In the three-dimensional case corresponding to propagation-based phase-contrast tomography with phase retrieval according to Paganin's method, the optimization of the imaging setup is studied with respect to the source size, the detector resolution, the geometrical magnification and the X-ray energy.

physics.med-ph

Signal-to-noise and spatial resolution in in-line imaging. 2. Phase-contrast tomography

In the first part of this paper, quantitative aspects of propagation-based phase-contrast imaging (PBI) were investigated using theoretical and numerical approaches, as well as experimental two-dimensional PBI images collected with plane monochromatic X-rays at a synchrotron beamline. In this second part, signal-to-noise ratio, spatial resolution and contrast are studied in connection with the radiation dose in three-dimensional PBI images of breast tissue samples obtained using propagation-based phase-contrast computed tomography (PB-CT) with energy-integrating and photon-counting detectors. The analysis is based on the theory of PBI and PB-CT using the homogeneous Transport of Intensity equation (Paganin's method). A biomedical image quality characteristic, suitable for quantitative assessment of X-ray images of biological samples, is introduced and applied. The key factors leading to high values of the biomedical imaging quality in PBI and to relatively low values of the same quality metric in CT imaging are identified and discussed in detail. This study is aimed primarily at developing tools for quantitative assessment and optimization of medical PB-CT imaging, initially at synchrotron facilities, with the prospect of subsequent transfer of the technology to medical clinics.

physics.med-ph

Signal-to-noise and spatial resolution in in-line imaging. 1. Basic theory, numerical simulations and planar experimental images

Signal-to-noise ratio and spatial resolution are quantitatively analysed in the context of in-line (propagation based) X-ray phase-contrast imaging. It is known that free-space propagation of a coherent X-ray beam from the imaged object to the detector plane, followed by phase retrieval in accordance with Paganin's method, can increase the signal-to-noise in the resultant images without deteriorating the spatial resolution. This results in violation of the noise-resolution uncertainty principle and demonstrates "unreasonable" effectiveness of the method. On the other hand, when the process of free-space propagation is performed in software, using the detected intensity distribution in the object plane, it cannot reproduce the same effectiveness, due to the amplification, during free-space propagation, of photon shot noise in the object-plane intensity. We show that the performance of Paganin's method is determined by just two dimensionless parameters: the Fresnel number and the ratio of the phase shift to the logarithm of intensity in the object plane. The relevant theoretical analysis is performed first, followed by computer simulations and then by a brief test using experimental images collected at a synchrotron beamline. More extensive experimental tests will be presented in the second part of this paper.

physics.med-ph

X-ray phase and dark-field computed tomography without optical elements

X-ray diffusive dark-field imaging, which allows spatially unresolved microstructure to be mapped across a sample, is an increasingly popular tool in an array of settings. Here, we present a new algorithm for phase and dark-field computed tomography based on the x-ray Fokker-Planck equation. Needing only a coherent x-ray source, sample, and detector, our propagation-based algorithm can map the sample density and dark-field/diffusion properties of the sample in 3D. Importantly, incorporating dark-field information in the density reconstruction process enables a higher spatial resolution reconstruction than possible with previous propagation-based approaches. Two sample exposures at each projection angle are sufficient for the successful reconstruction of both the sample density and dark-field Fokker-Planck diffusion coefficients. We anticipate that the proposed algorithm may be of benefit in biomedical imaging and industrial settings.

physics.med-ph

X-ray dark-field and phase retrieval without optics, via the Fokker-Planck equation

Emerging methods of x-ray imaging that capture phase and dark-field effects are equipping medicine with complementary sensitivity to conventional radiography. These methods are being applied over a wide range of scales, from virtual histology to clinical chest imaging, and typically require the introduction of optics such as gratings. Here, we consider extracting x-ray phase and dark-field signals from bright-field images collected using nothing more than a coherent x-ray source and detector. Our approach is based on the Fokker--Planck equation for paraxial imaging, which is the diffusive generalization of the transport-of-intensity equation. Specifically, we utilize the Fokker--Planck equation in the context of propagation-based phase-contrast imaging, where we show that two intensity images are sufficient for successful retrieval of the projected thickness and dark-field signals associated with the sample. We show the results of our algorithm using both a simulated dataset and an experimental dataset. These demonstrate that the x-ray dark-field signal can be extracted from propagation-based images, and that x-ray phase can be retrieved with better spatial resolution when dark-field effects are taken into account. We anticipate the proposed algorithm will be of benefit in biomedical imaging, industrial settings, and other non-invasive imaging applications.

physics.med-ph

Diffuse arrays that autocorrelate and project as delta-like points

Diffuse two-dimensional integer-valued arrays are demonstrated that have delta-like aperiodic autocorrelation and, simultaneously, the array sums form delta-like projections along several directions. The delta-projected views show a single sharp spike at the central ray. When such arrays are embedded in larger blocks of two-dimensional data, their location can be fixed precisely via the fast and simple intersection of the back-projected central rays along two or more directions. This mechanism complements localization of the same array from its delta-like autocorrelation, which, although more robust, is slower and more complex to compute.

eess.IV

Factors limiting quantitative phase retrieval in atomic-resolution differential phase contrast scanning transmission electron microscopy using a segmented detector

Quantitative differential phase contrast imaging of materials in atomic-resolution scanning transmission electron microscopy using segmented detectors is limited by various factors, including coherent and incoherent aberrations, detector positioning and uniformity, and scan-distortion. By comparing experimental case studies of monolayer and few-layer graphene with image simulations, we explore which parameters require the most precise characterisation for reliable and quantitative interpretation of the reconstructed phases. Coherent and incoherent lens aberrations are found to have the most significant impact. For images over a large field of view, the impact of noise and non-periodic boundary conditions are appreciable, but in this case study have less of an impact than artefacts introduced by beam deflections coupling to beam scanning (imperfect tilt-shift purity).

cond-mat.mtrl-sci

Extending the known families of scalable Huffman sequences

A canonical Huffman sequence is characterized by a zero inner-product between itself and each of its shifted copies, except at their largest relative shifts: their aperiodic auto-correlation then becomes delta-like, a single central peak surrounded by zeros, with one non-zero entry at each end. Prior work showed that the few known families of Huffman sequences (of length $N = 4n-1$, for integers $n > 1$, with continuously scalable elements) are based upon Fibonacci polynomials. Related multi-dimensional ($nD$) Huffman arrays were designed, as well as non-canonical quasi-Huffman arrays that also possess delta-like auto-correlations. We examined links between these discrete sequences and delta-correlated functions defined on the continuum, and provided simple non-iterative approaches to successfully deconvolve $nD$ data blurred by diffuse Huffman arrays. Here we describe new constructions for canonical Huffman sequences. Examples of length $N = 4n+1$, $N = 2n$ and families of arbitrary length are given, including scaled forms, as well as for Fibonacci-based arrays with perfect periodic auto-correlations, that are zero for all non-zero cyclic shifts. A generalization to include canonical sequences with complex scale factors invokes an equally useful dual form of delta-correlation. We also present $1D$ arrays with a much smaller dynamic range than those where the elements are built using Fibonacci recursion. When Huffman arrays (that are comprised of inherently signed values) are employed as diffuse probe beams for image acquisition, a new two-mask de-correlating step is described here that significantly reduces the total incident radiation dose compared to a prior method that added a positive pedestal-offset.

math.CO

Relative roles of multiple scattering and Fresnel diffraction in the imaging of small molecules using electrons, Part II: Differential Holographic Tomography

It has been argued that in atomic-resolution transmission electron microscopy (TEM) of sparse weakly scattering structures, such as small biological molecules, multiple electron scattering usually has only a small effect, while the in-molecule Fresnel diffraction can be significant due to the intrinsically shallow depth of focus. These facts suggest that the three-dimensional reconstruction of such structures from defocus image series collected at multiple rotational orientations of a molecule can be effectively performed for each atom separately, using the incoherent first Born approximation. The corresponding reconstruction method, termed here Differential Holographic Tomography, is developed theoretically and demonstrated computationally on several numerical models of biological molecules. It is shown that the method is capable of accurate reconstruction of the locations of atoms in a molecule from TEM data collected at a small number of random orientations of the molecule, with one or more defocus images per orientation. Possible applications to cryogenic electron microscopy and other areas are briefly discussed.

physics.optics

Dark-field signal extraction in propagation-based phase-contrast imaging

A method for extracting the dark-field signal in propagation-based phase-contrast imaging is proposed. In the case of objects consisting predominantly of a single material, or several different materials with similar ratios of the real decrement to the imaginary part of the complex refractive index, the proposed method requires a single image for extraction of the dark-field signal in two-dimensional projection imaging. In the case of three-dimensional tomographic imaging, the method needs only one image to be collected at each projection angle. A preliminary example demonstrates that this method can improve the visualization of microcalcifications in propagation-based X-ray breast cancer imaging. It is suggested that the proposed approach may be useful in other forms of biomedical imaging, where it can help one to obtain additional small-angle scattering information without increasing the radiation dose to the sample.

physics.med-ph

Suppressing dynamical diffraction artefacts in differential phase contrast scanning transmission electron microscopy of long-range electromagnetic fields via precession

In differential phase contrast scanning transmission electron microscopy (DPC-STEM), variability in dynamical diffraction resulting from changes in sample thickness and local crystal orientation (due to sample bending) can produce contrast comparable to that arising from the long-range electromagnetic fields probed by this technique. Through simulation we explore the scale of these dynamical diffraction artefacts and introduce a metric for the magnitude of their confounding contribution to the contrast. We show that precession over an angular range of a few milliradian can suppress this confounding contrast by one-to-two orders of magnitude. Our exploration centres around a case study of GaAs near the [011] zone-axis orientation using a probe-forming aperture semiangle on the order of 0.1 mrad at 300 keV, but the trends found and methodology used are expected to apply more generally.

cond-mat.mtrl-sci

Sharp images from diffuse beams: factorisation of the discrete delta function

Discrete delta functions define the limits of attainable spatial resolution for all imaging systems. Here we construct broad, multi-dimensional discrete functions that replicate closely the action of a Dirac delta function under aperiodic convolution. These arrays spread the energy of a sharp probe beam to simultaneously sample multiple points across the volume of a large object, without losing image sharpness. A diffuse point-spread function applied in any imaging system can reveal the underlying structure of objects less intrusively and with equal or better signal-to-noise ratio. These multi-dimensional arrays are related to previously known, but relatively rarely employed, one-dimensional integer Huffman sequences. Practical point-spread functions can now be made sufficiently large to span the size of the object under measure. Such large arrays can be applied to ghost imaging, which has demonstrated potential to greatly improve signal-to-noise ratios and reduce the total dose required for tomographic imaging. The discrete arrays built here parallel the continuum self-adjoint or Hermitian functions that underpin wave theory and quantum mechanics.

eess.IV

Simple wave-optical superpositions as prime number sieves

We encode the sequence of prime numbers into simple superpositions of identical waves, mimicking the archetypal prime number sieve of Eratosthenes. The primes are identified as zeros accompanied by phase singularities in a physically generated wave-field for integer valued momenta. Similarly, primes are encoded in the diffraction pattern from a simple single aperture and in the harmonics of a single vibrating resonator. Further, diffraction physics connections to number theory reveal how to encode all Gaussian primes, twin-primes, and how to construct wave fields with amplitudes equal to the divisor function at integer spatial frequencies. Remarkably, all of these basic diffraction phenomena reveal that the naturally irregular sequence of primes can arise from trivially ordered wave superpositions.

physics.optics

Probing the limits of the rigid-intensity-shift model in differential phase contrast scanning transmission electron microscopy

The rigid-intensity-shift model of differential phase contrast scanning transmission electron microscopy (DPC-STEM) imaging assumes that the phase gradient imposed on the probe by the sample causes the diffraction pattern intensity to shift rigidly by an amount proportional to that phase gradient. This behaviour is seldom realised exactly in practice. Through a combination of experimental results, analytical modelling and numerical calculations, we explore the breakdown of the rigid-intensity-shift behaviour and how this depends on the magnitude of the phase gradient and the relative scale of features in the phase profile and the probe size. We present guidelines as to when the rigid-intensity-shift model can be applied for quantitative phase reconstruction using segmented detectors, and propose probe-shaping strategies to further improve the accuracy.

physics.ins-det

On the efficiency of computational imaging with structured illumination

A generic computational imaging setup is considered which assumes sequential illumination of a semi-transparent object by an arbitrary set of structured illumination patterns. For each incident illumination pattern, all transmitted light is collected by a photon-counting bucket (single-pixel) detector. The transmission coefficients measured in this way are then used to reconstruct the spatial distribution of the object's projected transmission. It is demonstrated that the squared spatial resolution of such a setup is usually equal to the ratio of the image area to the number of linearly independent illumination patterns. If the noise in the measured transmission coefficients is dominated by photon shot noise, then the ratio of the spatially-averaged squared mean signal to the spatially-averaged noise variance in the "flat" distribution reconstructed in the absence of the object, is equal to the average number of registered photons when the illumination patterns are orthogonal. The signal-to-noise ratio in a reconstructed transmission distribution is always lower in the case of non-orthogonal illumination patterns due to spatial correlations in the measured data. Examples of imaging methods relevant to the presented analysis include conventional imaging with a pixelated detector, computational ghost imaging, compressive sensing, super-resolution imaging and computed tomography.

eess.IV

On the "unreasonable" effectiveness of Transport of Intensity imaging and optical deconvolution

The effectiveness of reconstructive imaging using the Homogeneous Transport of Intensity equation may be regarded as "unreasonable", because it has been shown to significantly increase signal-to-noise ratio while preserving spatial resolution, compared to equivalent conventional absorption-based imaging techniques at the same photon fluence. We reconcile this surprising behaviour by analysing the propagation of noise in typical in-line holography experiments. This analysis indicates that novel imaging techniques may be designed which produce high signal-to-noise images at low radiation doses without sacrificing spatial resolution.

physics.optics

Extraction of depth moments by exploiting the partial coherence of radiation

We retrieve depth information (moments) of an object using partially coherent fields and defocus induced holographic contrast. Our analysis leads to a form of tomography that does not require sample or source rotation. The tomography method presented here is performed with only two in-line images.

physics.optics