CAGE: An Internal Source Scanning Cryostat for HPGe Characterization

The success of current and future-generation neutrinoless double beta decay experiments relies on the ability to eliminate or reduce extraneous backgrounds. In addition to constructing experiments using radiopure materials and handling in underground laboratories, it is necessary to understand and reduce known backgrounds in data analysis. The Large Enriched Germanium Experiment for Neutrinoless double beta Decay is searching for this decay using 76Ge-enriched high-purity germanium detectors submerged in an active liquid argon veto. A significant background in LEGEND is surface events from shallowly-impinging radiation on detector surfaces. In this paper we introduce the Collimated Alphas, Gammas, and Electrons (CAGE) scanning system, an internal-source scanning vacuum cryostat, designed to perform studies of surface events on sensitive surfaces of HPGe in a surface-lab. CAGE features a collimated radionuclide source inside a movable infrared shield that is able to perform precision scans of detector surfaces by utilizing three independent motor stages for source positioning. This allows detailed studies of pulse shapes as a function of source position and incident angle, where defining features can be extracted and exploited for removing surface backgrounds in data analysis in LEGEND. In this paper, we describe CAGE and demonstrate its performance with a commissioning run with 241Am. The commissioning run was completed with the source at normal incidence, and we estimate a beam spot precision of 3.1 mm, which includes positioning uncertainties and the beam-spot size. Using the 59.5 keV gamma population from 241Am, we show that low-energy photon events near the passivated surface feature risetimes that increase with radial distance from the detector center. We suggest a specific metric that can be used to discriminate low-energy gamma backgrounds in LEGEND with similar characteristics.

physics.ins-det

Master Oscillator and Phase Reference Line Design for the PIP-II Linac

The phase averaging reference line system provides the RF phase reference, LO and clock signals to the LLRF and other accelerator sub-systems. The PIP-II linac has RF systems at three frequencies - 162.5 MHz, 325 MHz and 650 MHz. A temperature-stabilized, low-phase-noise oscillator is used as the master oscillator. Phase reference signals at 162.5 MHz, 325 MHz, and 650 MHz, along with LO signals at 182.5 MHz, 345 MHz, 670 MHz and LLRF clocks at 1320 MHz and 1300 MHz, are generated in temperature-controlled RF modules at each frequency section. A phase reference from each module travels to the next section, where it is doubled to produce required frequencies. The reference also travels alongside the accelerating cavities in the tunnel, allowing cavity probe and reference cables to temperature track and reduce measurement errors from temperature changes or phase drift.

physics.acc-ph

First Production of Skipper-CCD Modules for the DAMIC-M Experiment

The DAMIC-M experiment will search for sub-GeV dark matter particles with a large array of silicon skipper charge-coupled devices (CCDs) at the Modane Underground Laboratory (LSM) in France. After five years of development, we recently completed the production of 28 CCD modules at the University of Washington, each consisting of four 9-megapixel skipper CCDs. Material screening and background controls were implemented to meet stringent radio-purity targets, while extensive testing was employed to select science-grade CCDs for the modules and confirm their excellent performance after fabrication. Further testing at LSM will select 26 of these modules (${\sim}$350 g active mass) to be installed and operated in the DAMIC-M detector in early 2026.

physics.ins-det

The MAJORANA DEMONSTRATOR experiment's construction, commissioning, and performance

Background: The MAJORANA DEMONSTRATOR , a modular array of isotopically enriched high-purity germanium (HPGe) detectors, was constructed to demonstrate backgrounds low enough to justify building a tonne-scale experiment to search for the neutrinoless double-beta decay ($\beta\beta(0\nu)$) of $^{76}\mathrm{Ge}$. Purpose: This paper presents a description of the instrument, its commissioning, and operations. It covers the electroforming, underground infrastructure, enrichment, detector fabrication, low-background and construction techniques, electronics, data acquisition, databases, and data processing of the MAJORANA DEMONSTRATOR. Method: The MAJORANA DEMONSTRATOR operated inside an ultra-low radioactivity passive shield at the 4850-foot~level of the Sanford Underground Research Facility (SURF) from 2015-2021. Results and Conclusions: The MAJORANA DEMONSTRATOR achieved the best energy resolution and second-best background level of any $\beta\beta(0\nu)$ search. This enabled it to achieve an ultimate half-life limit on $\beta\beta(0\nu)$ in $^{76}\mathrm{Ge}$ of $8.3\times 10^{25}$~yr (90\% C.L.) and perform a rich set of searches for other physics beyond the Standard Model.

physics.ins-det

Performance of PIP-II High-beta 650 Cryomodule After Transatlantic Shipping

After shipment to the Daresbury Lab and return to Fermilab, the prototype HB650 cryomodule underwent another phase of 2K RF testing to ascertain any performance issues that may have arisen from the transport of the cryomodule. While measurements taken at room temperature after the conclusion of shipment indicated that there were no negative impacts on cavity alignment, beamline vacuum, or cavity frequency, testing at 2K was required to validate other aspects such as tuner operation, cavity coupling, cryogenic system integrity, and cavity performance. Results of this latest round of limited 2K testing will be presented.

physics.acc-ph

The DAMIC-M Low Background Chamber

The DArk Matter In CCDs at Modane (DAMIC-M) experiment is designed to search for light dark matter (m$_{\chi}$<10\,GeV/c$^2$) at the Laboratoire Souterrain de Modane (LSM) in France. DAMIC-M will use skipper charge-coupled devices (CCDs) as a kg-scale active detector target. Its single-electron resolution will enable eV-scale energy thresholds and thus world-leading sensitivity to a range of hidden sector dark matter candidates. A DAMIC-M prototype, the Low Background Chamber (LBC), has been taking data at LSM since 2022. The LBC provides a low-background environment, which has been used to characterize skipper CCDs, study dark current, and measure radiopurity of materials planned for DAMIC-M. It also allows testing of various subsystems like readout electronics, data acquisition software, and slow control. This paper describes the technical design and performance of the LBC.

physics.ins-det

The DAMIC-M Experiment: Status and First Results

The DAMIC-M (DArk Matter In CCDs at Modane) experiment employs thick, fully depleted silicon charged-coupled devices (CCDs) to search for dark matter particles with a target exposure of 1 kg-year. A novel skipper readout implemented in the CCDs provides single electron resolution through multiple non-destructive measurements of the individual pixel charge, pushing the detection threshold to the eV-scale. DAMIC-M will advance by several orders of magnitude the exploration of the dark matter particle hypothesis, in particular of candidates pertaining to the so-called "hidden sector." A prototype, the Low Background Chamber (LBC), with 20g of low background Skipper CCDs, has been recently installed at Laboratoire Souterrain de Modane and is currently taking data. We will report the status of the DAMIC-M experiment and first results obtained with LBC commissioning data.

hep-ex

The MAJORANA DEMONSTRATOR Readout Electronics System

The MAJORANA DEMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76-Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper provides a description of all components of the MAJORANA DEMONSTRATOR readout electronics, spanning the front-end electronics and internal cabling, back-end electronics, digitizer, and power supplies, along with the grounding scheme. The spectroscopic performance achieved with these readout electronics is also demonstrated.

physics.ins-det

PIP-II Injector Test Warm Front End: Commissioning Update

The Warm Front End (WFE) of the Proton Improvement Plan II Injector Test at Fermilab has been constructed to its full length. It includes a 15-mA DC, 30-keV H- ion source, a 2 m-long Low Energy Beam Transport (LEBT) with a switching dipole magnet, a 2.1 MeV CW RFQ, followed by a Medium Energy Beam Transport (MEBT) with various diagnostics and a dump. This report presents the commissioning status, focusing on beam measurements in the MEBT. In particular, a beam with the parameters required for injection into the Booster (5 mA, 0.55 ms macro-pulse at 20 Hz) was transported through the WFE.

physics.acc-ph

RF system for the MICE demonstration of ionization cooling

Muon accelerators offer an attractive option for a range of future particle physics experiments. They can enable high energy (TeV+) high energy lepton colliders whilst mitigating the difficulty of synchrotron losses, and can provide intense beams of neutrinos for fundamental physics experiments investigating the physics of flavor. The method of production of muon beams results in high beam emittance which must be reduced for efficient acceleration. Conventional emittance control schemes take too long, given the very short (2.2 microsecond) rest lifetime of the muon. Ionisation cooling offers a much faster approach to reducing particle emittance, and the international MICE collaboration aims to demonstrate this technique for the first time. This paper will present the MICE RF system and its role in the context of the overall experiment.

physics.acc-ph

Studies of the decays D^0 \rightarrow K_S^0K^-π^+ and D^0 \rightarrow K_S^0K^+π^-

The first measurements of the coherence factor R_{K_S^0Kπ} and the average strong--phase difference δ^{K_S^0Kπ} in D^0 \to K_S^0 K^\mpπ^\pm decays are reported. These parameters can be used to improve the determination of the unitary triangle angle γ in B^- \rightarrow $\widetilde{D}K^-$ decays, where $\widetilde{D}$ is either a D^0 or a D^0-bar meson decaying to the same final state, and also in studies of charm mixing. The measurements of the coherence factor and strong-phase difference are made using quantum-correlated, fully-reconstructed D^0D^0-bar pairs produced in e^+e^- collisions at the ψ(3770) resonance. The measured values are R_{K_S^0Kπ} = 0.70 \pm 0.08 and δ^{K_S^0Kπ} = (0.1 \pm 15.7)$^\circ$ for an unrestricted kinematic region and R_{K*K} = 0.94 \pm 0.12 and δ^{K*K} = (-16.6 \pm 18.4)$^\circ$ for a region where the combined K_S^0 π^\pm invariant mass is within 100 MeV/c^2 of the K^{*}(892)^\pm mass. These results indicate a significant level of coherence in the decay. In addition, isobar models are presented for the two decays, which show the dominance of the K^*(892)^\pm resonance. The branching ratio {B}(D^0 \rightarrow K_S^0K^+π^-)/{B}(D^0 \rightarrow K_S^0K^-π^+) is determined to be 0.592 \pm 0.044 (stat.) \pm 0.018 (syst.), which is more precise than previous measurements.

hep-ex

Updated measurements of absolute $D^+$ and $D^0$ hadronic branching fractions and $σ(e^+e^-\to D\overline{D})$ at $E_\mathrm{cm} = 3774$ MeV

Utilizing the full CLEO-c data sample of 818 pb$^{-1}$ of $e^+e^-$ data taken at the $ψ(3770)$ resonance, we update our measurements of absolute hadronic branching fractions of charged and neutral $D$ mesons. We previously reportedresults from subsets of these data. Using a double tag technique we obtain branching fractions for three $D^0$ and six $D^+$ modes, including the reference branching fractions $\mathcal{B} (D^0\to K^-π^+)=(3.934 \pm 0.021 \pm 0.061)\%$ and $\mathcal{B} (D^+ \to K^- π^+π^+)=(9.224 \pm 0.059 \pm 0.157)\%$. The uncertainties are statistical and systematic, respectively. In these measurements we include the effects of final-state radiation by allowing for additional unobserved photons in the final state, and the systematic errors include our estimates of the uncertainties of these effects. Furthermore, using an independent measurement of the luminosity, we obtain the cross sections $σ(e^+e^-\to D^0\overline{D}{}^0)=(3.607\pm 0.017 \pm 0.056) \ \mathrm{nb}$ and $σ(e^+e^-\to D^+D^-)=(2.882\pm 0.018 \pm 0.042) \ \mathrm{nb}$ at a center of mass energy, $E_\mathrm{cm} = 3774 \pm 1$ MeV.

hep-ex

Design and operation of a cryogenic charge-integrating preamplifier for the MuSun experiment

The central detector in the MuSun experiment is a pad-plane time projection ionization chamber that operates without gas amplification in deuterium at 31 K; it is used to measure the rate of the muon capture process $μ^- + d \rightarrow n + n + ν_μ$. A new charge-sensitive preamplifier, operated at 140 K, has been developed for this detector. It achieved a resolution of 4.5 keV(D$_2$) or 120 $e^-$ RMS with zero detector capacitance at 1.1 $μ$s integration time in laboratory tests. In the experimental environment, the electronic resolution is 10 keV(D$_2$) or 250 $e^-$ RMS at a 0.5 $μ$s integration time. The excellent energy resolution of this amplifier has enabled discrimination between signals from muon-catalyzed fusion and muon capture on chemical impurities, which will precisely determine systematic corrections due to these processes. It is also expected to improve the muon tracking and determination of the stopping location.

physics.ins-det

Improved Measurement of Absolute Hadronic Branching Fractions of the Ds+ Meson

The branching fractions of Ds meson decays serve to normalize many measurements of processes involving charm quarks. Using 586 pb^-1 of e+ e- collisions recorded at a center of mass energy of 4.17 GeV, we determine absolute branching fractions for 13 Ds decays in 16 reconstructed final states with a double tag technique. In particular we make a precise measurement of the branching fraction B(Ds -> K- K+ pi+) = (5.55 +- 0.14 +- 0.13)%, where the uncertainties are statistical and systematic respectively. We find a significantly reduced value of B(Ds -> pi+ pi0 eta') compared to the world average, and our results bring the inclusively and exclusively measured values of B(Ds -> eta' X)$ into agreement. We also search for CP-violating asymmetries in Ds decays and measure the cross-section of e+ e- -> Ds* Ds at Ecm = 4.17 GeV.

hep-ex

Design of MEBT for the Project X Injector Experiment at Fermilab

The Project X Injector Experiment (PXIE), a test bed for the Project X front end, will be completed at Fermilab at FY12-16. One of the challenging goals of PXIE is demonstration of the capability to form a 1 mA H- beam with an arbitrary selected bunch pattern from the initially 5 mA 162.5 MHz CW train. The bunch selection will be made in the Medium Energy Beam Transport (MEBT) at 2.1 MeV by diverting undesired bunches to an absorber. This paper presents the MEBT scheme and describes development of its elements, including the kickers and absorber.

physics.acc-ph

Progress with PXIE MEBT Chopper

A capability to provide a large variety of bunch patterns is crucial for the concept of the Project X serving MW-range beam to several experiments simultaneously. This capability will be realized by the Medium Energy Beam Transport's (MEBT) chopping system that will divert 80% of all bunches of the initially 5mA, 2.1 MeV CW 162.5 MHz beam to an absorber according to a pre-programmed bunch-by-bunch selection. Being considered one of the most challenging components, the chopping system will be tested at the Project X Injector Experiment (PXIE) facility that will be built at Fermilab as a prototype of the Project X front end. The bunch deflection will be made by two identical sets of travelling-wave kickers working in sync. Currently, two versions of the kickers are being investigated: a helical 200 Ohm structure with a switching-type 500 V driver and a planar 50 Ohm structure with a linear 250 V amplifier. This paper will describe the chopping system scheme and functional specifications for the kickers, present results of electromagnetic measurements of the models, discuss possible driver schemes, and show a conceptual mechanical design.

physics.acc-ph

Updated Measurement of the Strong Phase in D0 --> K+pi- Decay Using Quantum Correlations in e+e- --> D0 D0bar at CLEO

We analyze a sample of 3 million quantum-correlated D0 D0bar pairs from 818 pb^-1 of e+e- collision data collected with the CLEO-c detector at E_cm = 3.77 GeV, to give an updated measurement of \cosδand a first determination of \sinδ, where δis the relative strong phase between doubly Cabibbo-suppressed D0 --> K+pi- and Cabibbo-favored D0bar --> K+pi- decay amplitudes. With no inputs from other experiments, we find \cosδ= 0.81 +0.22+0.07 -0.18-0.05, \sinδ= -0.01 +- 0.41 +- 0.04, and |δ| = 10 +28+13 -53-0 degrees. By including external measurements of mixing parameters, we find alternative values of \cosδ= 1.15 +0.19+0.00 -0.17-0.08, \sinδ= 0.56 +0.32+0.21 -0.31-0.20, and δ= (18 +11-17) degrees. Our results can be used to improve the world average uncertainty on the mixing parameter y by approximately 10%.

hep-ex

Amplitude analysis of D0->K+K-pi+pi-

The first flavor-tagged amplitude analysis of the decay D0 to the self-conjugate final state K+K-pi+pi- is presented. Data from the CLEO II.V, CLEO III, and CLEO-c detectors are used, from which around 3000 signal decays are selected. The three most significant amplitudes, which contribute to the model that best fits the data, are phirho0, K1(1270)+-K-+, and non-resonant K+K-pi+pi-. Separate amplitude analyses of D0 and D0-bar candidates indicate no CP violation among the amplitudes at the level of 5% to 30% depending on the mode. In addition, the sensitivity to the CP-violating parameter gamma/phi3 of a sample of 2000 B+ -> D0-tilde(K+K-pi+pi-)K+ decays, where D0-tilde is a D0 or D0-bar, collected at LHCb or a future flavor facility, is estimated to be (11.3 +/- 0.3) degrees using the favored model.

hep-ex