SearcharxivSearch

arXiv subjects

D. Svirida

Publications and source records attributed to D. Svirida.

17 recordsLinked to original sources

Observation of light production by charged particles in WLS fibers

Wavelength shifting (WLS) fibers are widely used in particle physics for light collection from scintillators. Light production by charged particles directly in WLS fibers is traditionally ignored. In this study, light produced by charged particles in WLS fibers is clearly observed. The light yield of different batches of Y11(200) 1 mm diameter WLS fibers expressed in the number of detected photo electrons is as large as $23\pm2~\%$ with respect to the light yield of the Bicron BCF-12 1 mm diameter scintillating fiber. This corresponds to about 1200 photons per MeV light production after taking into account different fiber light trapping efficiencies and emission spectra. In clear fibers of the same diameter, no scintillation light is produced, while Cherenkov light is clearly seen at the 45-degree crossing angle. The observed amount of light produced by charged particles in the WLS fibers is not small and should be taken into account in advanced detector simulations.

physics.ins-det

Precision Light Yield and Crosstalk Characterization for the SuperFGD scintillator cubes

A detailed study of a $5\times5\times5$ cube prototype of the SuperFGD detector was performed using a 730 MeV/$c$ pion beam at the SC-1000 synchrocyclotron (PNPI, Gatchina, Russia). The detector, based on plastic scintillation cubes with orthogonal wavelength-shifting (WLS) fiber readout and silicon photomultipliers (SiPMs), was tested to evaluate its performance in terms of light yield, spatial uniformity, and optical crosstalk. Using high-resolution tracking, the spatial distribution of light yield was mapped with a granularity of 0.5 mm. An average light response map was obtained by combining data from 27 cubes. Optical crosstalk between adjacent cubes was also measured and characterized in four directions (left, right, up, down). Position-dependent crosstalk values ranged from 2% to 6%, with the highest levels observed near cube interfaces. These results confirm the excellent performance and scalability of the SuperFGD design, and provide valuable input for simulation tuning and reconstruction algorithms in the ND280 upgrade of the T2K experiment. The obtained result on the response uniformity and crosstalk are reasonably well described by simple MC model of the setup.

physics.ins-det

Direct determination of the $^{235}$U to $^{239}$Pu inverse beta decay yield ratio in the power reactor neutrino experiments

The yields of the inverse beta decay events produced by antineutrinos from a certain nuclear reactor fuel component are used by many experiments to check various model predictions. Yet measurements of the absolute yields feature significant uncertainties coming, mainly, from the understanding of the antineutrino detection efficiency. This work presents a simple novel approach to directly determine the $^{235}$U to $^{239}$Pu inverse beta decay yield ratio using the fuel evolution analysis. This ratio can be used for a sensitive test of reactor models, while the proposed method, results in smaller systematic uncertainties. The DANSS result on this ratio is one of the most precise among reactor neutrino experiments, yet does not significantly contradict to any previous measurement.

nucl-ex

Long term remote reactor power and fuel composition monitoring using antineutrinos

Electron antineutrinos are emitted in the decay chains of the fission products inside a reactor core and could be used for remote monitoring of nuclear reactors. The DANSS detector is placed under the core of the 3.1 GW power reactor at the Kalinin Nuclear Power Plant (KNPP) and collects up to 5000 antineutrino events per day. DANSS measured changes of the reactor power by antineutrino counting rates over 7 years with 1.0% accuracy in one week periods. The fission fractions of four major isotopes for the reactor power calculations were provided by KNPP. The systematic uncertainty of this measurement is less than 0.8%. It is comparable to the accuracy of conventional methods of the reactor power measurements while it is based on completely different approach. For the first time the 239Pu and 235U fission fractions were reconstructed using antineutrino inverse beta-decay spectrum which is a completely new technique. This method was applied to the data from three reactor fuel campaigns (approximately 1.5 year each). The reconstructed fission fractions in about two-week measurements and the fission fractions provided by KNPP coincide within better than 3% accuracy. This provides confidence in both completely different approaches of the fission fraction determination.

hep-ex

Study of polysterene based scintillator ageing in the DANSS experiment

DANSS is a spectrometer of reactor antineutrino based on plastic scintillator. The sensitive volume of the detector is made of 2500 polystyrene based scintillator plates with wavelength shifting (WLS) fiber readout (strips). We present a study of the strips light yield during 6.5 years of DANSS continuous running. Overall ageing at the rate $0.55 \pm 0.05(syst.)$ % per year is observed that is considerably smaller than in other similar experiments. We also observe the WLS fiber attenuation length shortening at the rate $0.26 \pm 0.04(stat.)$ % per year.

physics.ins-det

Application of the Duperier method to the analysis of the cosmic muon flux dependence on the meteorological parameters, based on the DANSS detector data

The detector DANSS is located under n industrial nuclear reactor at Kalininskaya Nuclear Power Plant. This location provides ~ 50 m.w.e. reduction of the cosmic muon flux in the vertical direction, which places the experiment in an intermediate position between ground and underground experiments in terms of shielding from the cosmic rays. The detector DANSS is located under an industrial nuclear reactor at Kalininskaya Nuclear Power Plant. This location provides ~50 m.w.e. reduction of the cosmic muon flux in the vertical direction, which places the experiment in an intermediate position between ground and underground experiments in terms of shielding from the cosmic rays. The detector's sensitive area consists of 2500 plastic scintillator counters, each 100x4x1 cm$^3$ in size, making in total a 1 m$^3$ volume, which is surrounded by a muon veto system and multiple layers of passive shielding. The main goal of the DANSS experiment is to study the antineutrino spectra at different distances from the source. For this purpose the detector is placed on a lifting platform, and the data is collected at three positions: 10.9 m, 11.9 m and 12.9 m from the center of the reactor core. The detector is capable of reconstructing muon tracks passing though the sensitive volume. In this work the barometric, height and temperature correlation coefficients are calculated in three areas of the zenith angle $\theta$ using the Duperier approach. These results are based on the muon data collected during four years.

physics.ins-det

SuperFGD prototype time resolution studies

The SuperFGD will be a part of the ND280 near detector of the T2K and Hyper Kamiokande projects, that will help to reduce systematic uncertainties related with neutrino flux and cross-section modeling. The upgraded ND280 will be able to perform a full exclusive reconstruction of the final state from neutrino-nucleus interactions, including measurements of low momentum protons, pions and, for the first time, event-by event measurements of neutron kinematics. The time resolution defines the neutron energy resolution. We present the results of time resolution measurements made with the SuperFGD prototype that consists of 9216 plastic scintillator cubes (cube size is 1 cm$^3$) readout with 1728 wavelength-shifting fibers going along three orthogonal directions. We use data from the muon beam exposure at CERN. The time resolution of 0.97 ns was obtained for one readout channel after implementing the time calibration with a correction for the time-walk effect. The time resolution improves with energy deposited in a scintillator cube. Averaging two readout channels for one scintillator cube improves the time resolution to 0.68 ns which means that signals in different channels are not synchronous. Therefore the contribution from the time recording step of 2.5 ns is averaged as well. Averaging time values from N channels improves the time resolution by $\sim 1/\sqrt{N}$. Therefore a very good time resolution should be achievable for neutrons since neutron recoils hit typically several scintillator cubes and in addition produce larger amplitudes than muons. Measurements performed with a laser and a wide-bandwidth oscilloscope demonstrated that the time resolution obtained with the muon beam is not far from its expected limit. The intrinsic time resolution of one channel is 0.67 ns for signals of 56 photo-electron typical for minimum ionizing particles.

physics.ins-det

Precision small scattering angle measurements of proton-proton and proton-nucleus analyzing powers at the RHIC hydrogen jet polarimeter

At RHIC, the hydrogen jet target polarimeter (HJET) is used to measure proton beam polarization with accuracy $σ_P^\text{syst}/P\lesssim0.5\%$ by counting low energy (1--10 MeV) recoil protons in left-right symmetric detectors. The HJET performance also allowed us to precisely measure $pp$ and $p$A (where A is any ion stored at RHIC) analyzing powers in the CNI region. The results of the measurements are discussed.

hep-ex

Observation of the temperature and barometric effects on the cosmic muon flux by the DANSS detector

The DANSS detector is located directly below a commercial reactor core at the Kalinin Nuclear Power Plant. Such a position provides an overburden about 50 m.w.e. in vertical direction. In terms of the cosmic rays it occupies an intermediate position between surface and underground detectors. The sensitive volume of the detector is a cubic meter of plastic scintillator with fine segmentation and combined PMT and SiPM readout, surrounded by multilayer passive and active shielding. The detector can reconstruct muon tracks passing through its sensitive volume. The main physics goal of the DANSS experiment implies the antineutrino spectra measurements at various distances from the source. This is achieved by means of a lifting platform so that the data is taken in three positions - 10.9, 11.9 and 12.9 meters from the reactor core. The muon data were collected for nearly four calendar years. The overburden parameters $\langle E_{thr}\cosθ\rangle$ and $\langle E_{thr} \rangle$, as well as the temperature and barometric correlation coefficients are evaluated separately for the three detector positions and, in each position, in three ranges of the zenith angle - for nearly vertical muons with $\cosθ>0.9$, for nearly horizontal muons with $\cosθ<0.36$, and for the whole upper hemisphere.

physics.ins-det

Optimized scintillation strip design for the DANSS upgrade

DANSS is a one cubic meter plastic scintillator detector with a primary goal of the sterile neutrino searches at a commercial nuclear reactor. Due to its highly advantageous location, fine segmentation and ability to change the distance to the neutrino production origin DANSS is ahead of many similar experiments around the world in terms of the counting rate, signal to background ratio and sterile neutrino exclusion regions. Yet a moderate energy resolution of the detector prevents the further progress in the physics program. The main challenge of the planned upgrade is to achieve the energy resolution of 12% at 1 MeV. The new design of the main sensitive element - the plastic scintillation strip - is the most important step forward. The strip prototypes were manufactured and tested at the pion beam of the PNPI synchrocyclotron. More than twice higher light output together with fairly flat detector response uniformity, longitudinal timing information and other optimizations will surely help to reach the upgrade goal. The paper discusses the drawbacks of the current strip version, outlines the new features of the proposed upgrade, describes the beam test procedure and presents the test results reflecting the advantages of the new strip design in comparison with the currently used version.

physics.ins-det

The performance of a new Kuraray wavelength shifting fiber YS-2

Wavelength shifting fibers are widely used for light collection from scintillation counters, which allow connection of various scintillation planes to relatively small photocathodes of photodetectors and especially tiny photocathodes of silicon photo-multipliers. In October 2020 Kuraray announced production of a new branch of faster fibers. We performed a comparison of the new fiber YS-2 to a mature Y-11. The fiber YS-2 demonstrated decay time nearly two times shorter than that of Y-11: $\approx$4.0 ns versus $\approx$7.4 ns. At the same time its light yield and attenuation length are as good as of Y-11, which makes YS-2 a good choice for timing scintillation detectors.

physics.ins-det

Precision Small Scattering Angle Measurements of Elastic Proton-Proton Single and Double Spin Analyzing Powers at the RHIC Hydrogen Jet Polarimeter

The Polarized Atomic Hydrogen Gas Jet Target polarimeter is employed by the Relativistic Heavy Ion Collider (RHIC) to measure the absolute polarization of each colliding proton beam. Polarimeter detectors and data acquisition were upgraded in 2015 to increase solid angle, energy range and energy resolution. These upgrades and advanced systematic error analysis along with improved beam intensity and polarization in RHIC runs 2015 ($E_\textrm{beam}=100\,\text{GeV}$) and 2017 ($255\,\text{GeV}$) allowed us to greatly reduce the statistical and systematic uncertainties for elastic spin asymmetries, $A_N(t)$ and $A_NN(t)$, in the Coulomb-nuclear interference momentum transfer range $0.0013<-t<0.018\,\text{GeV}^2$. For the first time hadronic single spin-flip $r_5$ and double spin-flip $r_2$ amplitude parameters were reliably isolated at these energies and momentum transfers. Measurements at two beam energies enable a separation of Pomeron and Regge pole contributions to $r_5(s)$ and $r_2(s)$, indicating that the spin component may persist at high energies.

hep-ex

Search for sterile neutrinos at the DANSS experiment

DANSS is a highly segmented 1~m${}^3$ plastic scintillator detector. Its 2500 one meter long scintillator strips have a Gd-loaded reflective cover. The DANSS detector is placed under an industrial 3.1~$\mathrm{GW_{th}}$ reactor of the Kalinin Nuclear Power Plant 350~km NW from Moscow. The distance to the core is varied on-line from 10.7~m to 12.7~m. The reactor building provides about 50~m water-equivalent shielding against the cosmic background. DANSS detects almost 5000 $\widetildeν_e$ per day at the closest position with the cosmic background less than 3$\%$. The inverse beta decay process is used to detect $\widetildeν_e$. Sterile neutrinos are searched for assuming the $4ν$ model (3 active and 1 sterile $ν$). The exclusion area in the $Δm_{14}^2,\sin^22θ_{14}$ plane is obtained using a ratio of positron energy spectra collected at different distances. Therefore results do not depend on the shape and normalization of the reactor $\widetildeν_e$ spectrum, as well as on the detector efficiency. Results are based on 966 thousand antineutrino events collected at 3 distances from the reactor core. The excluded area covers a wide range of the sterile neutrino parameters up to $\sin^22θ_{14}<0.01$ in the most sensitive region.

hep-ex

Characterisation of Medipix3 Silicon Detectors in a Charged-Particle Beam

While designed primarily for X-ray imaging applications, the Medipix3 ASIC can also be used for charged-particle tracking. In this work, results from a beam test at the CERN SPS with irradiated and non-irradiated sensors are presented and shown to be in agreement with simulation, demonstrating the suitability of the Medipix3 ASIC as a tool for characterising pixel sensors.

physics.ins-det

DANSSino: a pilot version of the DANSS neutrino detector

DANSSino is a reduced pilot version of a solid-state detector of reactor antineutrinos (to be created within the DANSS project and installed under the industrial 3 GW(th) reactor of the Kalinin Nuclear Power Plant -- KNPP). Numerous tests performed at a distance of 11 m from the reactor core demonstrate operability of the chosen design and reveal the main sources of the background. In spite of its small size (20x20x100 ccm), the pilot detector turned out to be quite sensitive to reactor antineutrinos, detecting about 70 IBD events per day with the signal-to-background ratio about unity.

physics.ins-det

Absolute Polarization Measurements at RHIC in the Coulomb Nuclear Interference Region

The Relativistic Heavy Ion Collider at Brookhaven National Laboratory provides polarized proton beams for the investigation of the nucleon spin structure. For polarimetry, carbon-proton and proton-proton scattering is used in the Coulomb nuclear interference region at small momentum transfer ($-t$). Fast polarization measurements of each beam are carried out with carbon fiber targets at several times during an accelerator store. A polarized hydrogen gas jet target is needed for absolute normalization over multiple stores, while the target polarization is constantly monitored in a Breit-Rabi polarimeter. In 2005, the jet polarimeter has been used with both RHIC beams. We present results from the jet polarimeter including a detailed analysis of background contributions to asymmetries and to the beam polarization.

nucl-ex

Measurement of Analyzing Power for Proton-Carbon Elastic Scattering in the Coulomb-Nuclear Interference Region with a 22-GeV/c Polarized Proton Beam

The analyzing power for proton-carbon elastic scattering in the coulomb-nuclear interference region of momentum transfer, $9.0\times10^{-3}<-t<4.1\times10^{-2}$ (GeV/$c)^{2}$, was measured with a 21.7 GeV/$c$ polarized proton beam at the Alternating Gradient Synchrotron of Brookhaven National Laboratory. The ratio of hadronic spin-flip to non-flip amplitude, $r_5$, was obtained from the analyzing power to be $\text{Re} r_5=0.088\pm 0.058$ and $\text{Im} r_5=-0.161\pm 0.226$.

hep-ex