SearcharxivSearch

arXiv subjects

Daisuke Akamatsu

Publications and source records attributed to Daisuke Akamatsu.

At least 19 recordsLinked to original sources

Quantum Storage of Frequency-Multiplexed Photons Exhibiting Nonclassical Correlations with Telecom C-Band Photons

Multiplexing is essential for improving entanglement distribution rates in quantum communication. Frequency multiplexing provides a promising and scalable path toward large-capacity quantum networks. Further progress requires increasing the number of frequency modes and developing broadband photon-pair sources and quantum memories that are spectrally compatible. Here, we report the integration of a cavity-enhanced spontaneous parametric down-conversion source in the telecom C-band with a frequency-multiplexed atomic frequency comb memory. The bow-tie cavity source was simultaneously resonant at 606 nm and 1550 nm, generating non-degenerate photon pairs exhibiting a clustered frequency-comb spectrum. The atomic frequency comb memory, implemented in Praseodymium-doped Yttrium Orthosilicate crystals, provided up to 83 frequency modes with 123 MHz spacing and enabled broadband storage of 606 nm signal photons. By filtering the main cluster, we obtained $32.7 \pm 4.8$ effective modes, as confirmed from coincidence measurements. Importantly, we observed strong nonclassical correlations after storage, with cross-correlation values of $g_{s,i}^{(2)} = 8.1\pm0.7$. Our experimental results demonstrate the feasibility of integrating cavity-enhanced photon-pair sources with rare-earth-ion-doped solid-state memories. The integration reveals a high frequency multiplicity that is essential for scalable quantum networks.

quant-ph

Coordinated international comparisons between optical clocks connected via fiber and satellite links

Optical clocks provide ultra-precise frequency references that are vital for international metrology as well as for tests of fundamental physics. To investigate the level of agreement between different clocks, we simultaneously measured the frequency ratios between ten optical clocks in six different countries, using fiber and satellite links. This is the largest coordinated comparison to date, from which we present a subset of 38 optical frequency ratios and an evaluation of the correlations between them. Four ratios were measured directly for the first time, while others had significantly lower uncertainties than previously achieved, supporting the advance towards a redefinition of the second and the use of optical standards for international time scales.

physics.atom-ph

Improved absolute frequency measurement of $^{171}$Yb at NMIJ with uncertainty below $2\times10^{-16}$

We report improved absolute frequency measurement of the $^{1}$S$_{0}-^{3}$P$_{0}$ transition of $^{171}$Yb at National Metrology Institute of Japan (NMIJ) by comparing the $^{171}$Yb optical lattice clock NMIJ-Yb1 with 13 Cs primary frequency standards via International Atomic Time from August 2021 to May 2023. The measured absolute frequency is 518 295 836 590 863.62(10) Hz with a fractional uncertainty of $1.9\times10^{-16}$, in good agreement with the recommended frequency of $^{171}$Yb as a secondary representation of the second. This uncertainty is 2.6 times lower than our previous measurement uncertainty, and slightly lower than any uncertainties of the absolute frequency measurements of $^{171}$Yb that have so far been reported by other institutes. We also estimate correlation coefficients between our present and previous measurements, which is important for updating the recommended frequency.

physics.atom-ph

Generation of a precise time scale assisted by a near-continuously operating optical lattice clock

We report on a reduced time variation of a time scale with respect to Coordinated Universal Time (UTC) by steering a hydrogen-maser-based time scale with a near-continuously operating optical lattice clock. The time scale is generated in a post-processing analysis for 230 days with a hydrogen maser with its fractional frequency stability limited by a flicker floor of $2\times10^{-15}$ and an Yb optical lattice clock operated with an uptime of 81.6 $\%$. During the 230-day period, the root mean square time variation of our time scale with respect to UTC is 0.52 ns, which is a better performance compared with those of time scales steered by microwave fountain clocks that exhibit root mean square variations from 0.99 ns to 1.6 ns. With the high uptime achieved by the Yb optical lattice clock, our simulation implies the potential of generating a state-of-the-art time scale with a time variation of $<0.1$ ns over a month using a better hydrogen maser reaching the mid $10^{-16}$ level. This work demonstrates that a use of an optical clock with a high uptime enhances the stability of a time scale.

physics.atom-ph

Search for ultralight dark matter from long-term frequency comparisons of optical and microwave atomic clocks

We search for ultralight scalar dark matter candidates that induce oscillations of the fine structure constant, the electron and quark masses, and the quantum chromodynamics energy scale with frequency comparison data between an $^{171}$Yb optical lattice clock and a $^{133}$Cs fountain microwave clock that span 298 days with an uptime of 15.4 $\%$. New limits on the couplings of the scalar dark matter to electrons and gluons in the mass range from $10^{-22}$ eV/$c^{2}$ to $10^{-20}$ eV/$c^{2}$ are set, assuming that each of these couplings is the dominant source of the modulation in the frequency ratio. The absolute frequency of the $^{171}$Yb clock transition is also determined as $518\,295\,836\,590\,863.69(28)$ Hz, which is one of the important contributions towards a redefinition of the SI second.

physics.atom-ph

Demonstration of the nearly continuous operation of an $^{171}$Yb optical lattice clock for half a year

Optical lattice clocks surpass primary Cs microwave clocks in frequency stability and accuracy, and are promising candidates for a redefinition of the second in the International System of Units (SI). However, the robustness of optical lattice clocks has not yet reached a level comparable to that of Cs fountain clocks which contribute to International Atomic Time (TAI) by the nearly continuous operation. In this paper, we report the long-term operation of an $^{171}$Yb optical lattice clock with a coverage of 80.3% for half a year including uptimes of 93.9% for the first 24 days and 92.6% for the last 35 days. This enables a nearly dead-time-free frequency comparison of the optical lattice clock with TAI over months, which provides a link to the SI second with an uncertainty of low $10^{-16}$. By using this link, the absolute frequency of the $^{1}$S$_{0}-^{3}$P$_{0}$ clock transition of $^{171}$Yb is measured as 518 295 836 590 863.54(26) Hz with a fractional uncertainty of $5.0\times10^{-16}$. This value is in agreement with the recommended frequency of $^{171}$Yb as a secondary representation of the second.

physics.atom-ph

Improved Frequency Ratio Measurement with 87Sr and 171Yb Optical Lattice Clocks at NMIJ

We report improved frequency ratio measurement with $^{87}$Sr and $^{171}$Yb optical lattice clocks at the National Metrology Institute of Japan (NMIJ). The $^{87}$Sr optical lattice clock is enhanced with several major modifications and is re-evaluated with a reduced uncertainty of $1.1\times10^{-16}$. We employed a $^{171}$Yb optical lattice clock with an uncertainty of $4\times10^{-16}$ that was developed for contributing to International Atomic Time (TAI). The measurement result is $ν_{\mathrm{Yb}}/ν_{\mathrm{Sr}}$ = 1.207 507 039 343 338 58(49)$_{\mathrm{sys}}$(6)$_{\mathrm{stat}}$ with a fractional uncertainty of $4.1\times10^{-16}$, which is 3.4 times smaller than our previous measurement result.

physics.atom-ph

Entanglement-Enhanced Optical Atomic Clock

State-of-the-art atomic clocks are based on the precise detection of the energy difference between two atomic levels, measured as a quantum phase accumulated in a given time interval. Optical-lattice clocks (OLCs) now operate at or near the standard quantum limit (SQL) that arises from the quantum noise associated with discrete measurement outcomes. While performance beyond the SQL has been achieved in microwave clocks and other atomic sensors by engineering quantum correlations (entanglement) between the atoms, the generation of entanglement on an optical-clock transition and operation of such a clock beyond the SQL represent major goals in quantum metrology that have never been demonstrated. Here we report creation of a many-atom entangled state on an optical transition, and demonstrate an OLC with an Allan deviation below the SQL. We report a metrological gain of $4.4^{+0.6}_{-0.4}$ dB over the SQL using an ensemble consisting of a few hundred 171Yb atoms, allowing us to reach a given stability $2.8{\pm}0.3$ times faster than the same clock operated at the SQL. Our results should be readily applicable to other systems, thus enabling further advances in timekeeping precision and accuracy. Entanglement-enhanced OLCs will have many scientific and technological applications, including precision tests of the fundamental laws of physics, geodesy, or gravitational wave detection.

quant-ph

Near-Unitary Spin Squeezing in $^{171}$Yb

Spin squeezing can improve atomic precision measurements beyond the standard quantum limit (SQL), and unitary spin squeezing is essential for improving atomic clocks. We report substantial and nearly unitary spin squeezing in $^{171}$Yb, an optical lattice clock atom. The collective nuclear spin of $\sim 10^3$ atoms is squeezed by cavity feedback, using light detuned from the system's resonances to attain unitarity. The observed precision gain over the SQL is limited by state readout to 6.5(4) dB, while the generated states offer a gain of 12.9(6) dB, limited by the curvature of the Bloch sphere. Using a squeezed state within 30% of unitarity, we demonstrate an interferometer that improves the averaging time over the SQL by a factor of 3.7(2). In the future, the squeezing can be simply transferred onto the optical clock transition of $^{171}$Yb.

physics.atom-ph

Geometrically asymmetric optical cavity for strong atom-photon coupling

Optical cavities are widely used to enhance the interaction between atoms and light. Typical designs using a geometrically symmetric structure in the near-concentric regime face a tradeoff between mechanical stability and high single-atom cooperativity. To overcome this limitation, we design and implement a geometrically asymmetric standing-wave cavity. This structure, with mirrors of very different radii of curvature, allows strong atom-light coupling while exhibiting good stability against misalignment. We observe effective cooperativities ranging from $η_{\rm eff}=10$ to $η_{\rm eff}=0.2$ by shifting the location of the atoms in the cavity mode. By loading $^{171}$Yb atoms directly from a mirror magneto-optical trap into a one-dimensional optical lattice along the cavity mode, we produce atomic ensembles with collective cooperativities up to $Nη=2\times 10^4$. This system opens a way to preparing spin squeezing for an optical lattice clock and to accessing a range of nonclassical collective states.

physics.atom-ph

Uncertainty evaluation of an $^{171}$Yb optical lattice clock at NMIJ

We report an uncertainty evaluation of an $^{171}$Yb optical lattice clock with a total fractional uncertainty of $3.6\times10^{-16}$, which is mainly limited by the lattice-induced light shift and the blackbody radiation shift. Our evaluation of the lattice-induced light shift, the density shift, and the second-order Zeeman shift is based on an interleaved measurement where we measure the frequency shift using the alternating stabilization of a clock laser to the $\mathrm{6s^{2}\,^{1}S_{0}-6s6p\,^{3}P_{0}}$ clock transition with two different experimental parameters. In the present evaluation, the uncertainties of two sensitivity coefficients for the lattice-induced hyperpolarizability shift $d$ incorporated in a widely-used light shift model by RIKEN and the second-order Zeeman shift $a_{\mathrm{Z}}$ are improved compared with the uncertainties of previous coefficients. The hyperpolarizability coefficient $d$ is determined by investigating the trap potential depth and the light shifts at the lattice frequencies near the two-photon transitions $\mathrm{6s6p^{3}P_{0}-6s8p^{3}P_{0}}$, $\mathrm{6s8p^{3}P_{2}}$, and $\mathrm{6s5f^{3}F_{2}}$. The obtained values are $d=-1.1(4)$ $\mathrmμ$Hz and $a_{\mathrm{Z}}=-6.6(3)$ Hz/mT$^{2}$. These improved coefficients should reduce the total systematic uncertainties of Yb lattice clocks at other institutes.

physics.atom-ph

Dual-Mode Operation of an Optical Lattice Clock Using Strontium and Ytterbium Atoms

We have developed an optical lattice clock that can operate in dual modes: a strontium (Sr) clock mode and an ytterbium (Yb) clock mode. Dual-mode operation of the Sr-Yb optical lattice clock is achieved by alternately cooling and trapping $^{87}$Sr and $^{171}$Yb atoms inside the vacuum chamber of the clock. Optical lattices for Sr and Yb atoms were arranged with horizontal and vertical configurations, respectively, resulting in a small distance of the order of 100 $μ$m between the trapped Sr and Yb atoms. The $^{1}$S$_{0}$-$^{3}$P$_{0}$ clock transitions in the trapped atoms were interrogated in turn and the clock lasers were stabilized to the transitions. We demonstrated the frequency ratio measurement of the Sr and Yb clock transitions by using the dual-mode operation of the Sr-Yb optical lattice clock. The dual-mode operation can reduce the uncertainty of the blackbody radiation shift in the frequency ratio measurement, because both Sr and Yb atoms share the same blackbody radiation.

physics.atom-ph

A frequency-stabilized light source at 399 nm using an Yb hollow-cathode lamp

We demonstrate a diode laser system operating at 399 nm that is stabilized to the ${\rm 6s^{2}\ {^1}S_{0} - 6s6p\ {^1}P_{1}}$ electric dipole transition in ytterbium (Yb) atoms in a hollow-cathode lamp. The frequency stability of the laser reached $1.1 \times 10^{-11}$ at an averaging time of $τ= 1\ \mathrm{s}$. We performed an absolute frequency measurement using an optical frequency comb and determined that the absolute frequency of the laser stabilized to the ${\rm {^1}S_{0} - {^1}P_{1}}$ transition in $^{174}\mathrm{Yb}$ was 751 526 522.26(9) MHz. We also investigated several systematic frequency shifts while changing some of the light source parameters and measured several isotope shifts. The measured laser frequency will provide useful information regarding the practical use of the frequency-stabilized light source at 399 nm.

physics.atom-ph

Second harmonic generation at 399 nm resonant on the $^{1}S_{0}-^{1}P_{1}$ transition of ytterbium using a periodically poled LiNbO$_{3}$ waveguide

We demonstrate a compact and robust method for generating a 399-nm light resonant on the $^{1}S_{0}-^{1}P_{1}$ transition in ytterbium using a single-pass periodically poled LiNbO$_{3}$ waveguide for second harmonic generation (SHG). The obtained output power at 399 nm was 25 mW when a 798-nm fundamental power of 380 mW was coupled to the waveguide. We observed no degradation of the SHG power for 13 hours with a low power of 6 mW. The obtained SHG light has been used as a seed light for injection locking, which provides sufficient power for laser cooling ytterbium.

physics.atom-ph

Absolute frequency measurements and hyperfine structures of the molecular iodine transitions at 578 nm

We report absolute frequency measurements of 81 hyperfine components of the rovibrational transitions of molecular iodine at 578 nm using the second harmonic generation of an 1156-nm external-cavity diode laser and a fiber-based optical frequency comb. The relative uncertainties of the measured absolute frequencies are typically $1.4\times10^{-11}$. Accurate hyperfine constants of four rovibrational transitions are obtained by fitting the measured hyperfine splittings to a four-term effective Hamiltonian including the electric quadrupole, spin-rotation, tensor spin-spin, and scalar spin-spin interactions. The observed transitions can be good frequency references at 578 nm, and are especially useful for research using atomic ytterbium since the transitions are close to the $^{1}S_{0}-^{3}P_{0}$ clock transition of ytterbium.

physics.atom-ph

Improved frequency measurement of the $^1S_{0}$-$^3P_{0}$ clock transition in $^{87}$Sr using the Cs fountain clock at NMIJ as a transfer oscillator

We performed an absolute frequency measurement of the $^1S_{0}$-$^3P_{0}$ transition in $^{87}$Sr with a fractional uncertainty of $1.2 \times 10^{-15}$, which is less than one third that of our previous measurement. A caesium fountain atomic clock was used as a transfer oscillator to reduce the uncertainty of the link between a strontium optical lattice clock and the SI second. The absolute value of the transition frequency is 429 228 004 229 873.56(49) Hz.

physics.atom-ph

A compact iodine-laser operating at 531 nm with stability at the 10$^{-12}$ level and using a coin-sized laser module

We demonstrate a compact iodine-stabilized laser operating at 531 nm using a coin-sized light source consisting of a 1062-nm distributed-feedback diode laser and a frequency-doubling element. A hyperfine transition of molecular iodine is observed using the light source with saturated absorption spectroscopy. The light source is frequency stabilized to the observed iodine transition and achieves frequency stability at the 10$^{-12}$ level. The absolute frequency of the compact laser stabilized to the $a_{1}$ hyperfine component of the $R(36)32-0$ transition is determined as $564\,074\,632\,419(8)$ kHz with a relative uncertainty of $1.4\times10^{-11}$. The iodine-stabilized laser can be used for various applications including interferometric measurements.

physics.optics

Binary phase oscillation of two mutually coupled semiconductor lasers

A two-site Ising model is implemented as an injection-locked laser network consisting of a single master laser and two mutually coupled slave lasers. We observed ferromagnetic and antiferromagnetic orders in the in-phase and out-of-phase couplings between the two slave lasers. Their phase difference is locked to either 0 or p even if the coupling path is continuously modulated. The system automatically selects the oscillation frequency to satisfy the in-phase or out-of-phase coupling condition, when the mutual coupling dominates over the injection-locking by the master laser.

quant-ph