Searcharxiv⌕ Search

arXiv subjects

Daniya Zinatulina

Publications and source records attributed to Daniya Zinatulina.

4 recordsLinked to original sources

Characterization of Aluminum Microwave SQUID Multiplexers for CE$ν$NS Detection

We present the design, fabrication, and characterization of an aluminum-based six-channel microwave SQUID multiplexer ($μ$MUX) prototype for transition-edge sensor (TES) readout in the RICOCHET experiment. The device consists of aluminum coplanar-waveguide resonators and RF SQUIDs with Dolan-style Al/AlO$_x$/Al Josephson junctions. By measuring the resonator scattering parameters at a range of probe tone frequencies, powers, and flux bias points, we demonstrate agreement between the device response and existing multiplexer models. We also characterize the noise performance in both open-loop and flux-ramping modes. With a high electron mobility transistor (HEMT) amplifier, open-loop measurements yield a flux sensitivity of 1-1.5 $μΦ_0/\sqrt{Hz}$. With flux-ramp modulation, low-frequency 1/f noise is suppressed, and the flux sensitivity is around 3-4 $μΦ_0/\sqrt{Hz}$, corresponding to a current sensitivity of 24-33 $pA/\sqrt{Hz}$ at the input coil. We further demonstrate a reduction in readout noise by incorporating a Josephson traveling-wave parametric amplifier (JTWPA) between the $μ$MUX and the HEMT. This achieves an open-loop flux sensitivity of 0.3-0.6 $μΦ_0/\sqrt{Hz}$ and an effective system noise temperature below 1 K. These results establish aluminum $μ$MUX devices as a viable and extensible readout technology for low-noise cryogenic detector arrays.

physics.ins-det↗

Characterization of mini-CryoCube detectors from the Ricochet experiment commissioning at the Institut Laue-Langevin

The Ricochet experiment aims to measure the coherent elastic neutrino-nucleus scattering process from antineutrinos emitted by a research nuclear reactor operated by the Institut Laue-Langevin (Grenoble, France). This article presents a description of the Ricochet experimental installation and the detector performance achieved during its commissioning with a mini-CryoCube module consisting of three 42-gram germanium cryogenic calorimeters. The baseline resolutions and background levels are reported both during reactor-on and reactor-off periods, and as noise mitigation techniques were improved. A baseline resolution of 40 eV electron equivalent was achieved for the ionization channel after setup improvements, and the phonon channel resolutions ranged from 50 to 80 eV of total phonon energy. In the energy region from 2 to 7 keV, a nuclear recoil rate of 15(2) events/(kg day keV) is measured during the reactor-off period selecting events in coincidence with muon veto signals. This rate is in agreement with the cosmogenic neutron rate calculated from GEANT4 simulations. After the rejection of events in coincidence with signals in the muon veto detectors, a combined 90% C.L. limit on the nuclear recoil background of < 9 events/(kg day keV) is obtained in that energy region during the reactor-on period, which is compatible with our GEANT4 model calculation corresponding to a total rate of 5 events/(kg day keV). The sensitivity of this analysis was however found to be limited by a surface event contamination which is currently being addressed by the Ricochet Collaboration with upgraded detectors.

hep-ex↗

The MONUMENT Experiment: Ordinary Muon Capture studies for 0$νββ$ decay

The MONUMENT experiment measures ordinary muon capture (OMC) on isotopes relevant for neutrinoless double-beta (0$νββ$) decay and nuclear astrophysics. OMC is a particularly attractive tool for improving the theoretical description of 0$νββ$ decay. It involves similar momentum transfers and allows testing the virtual transitions involved in 0$νββ$ decay against experimental data. During the 2021 campaign, MONUMENT measured OMC on $^{76}$Se and $^{136}$Ba, the isotopes relevant for next-generation 0$νββ$ decay searches, like LEGEND and nEXO. The experimental setup has been designed to accurately extract the total and partial muon capture rates, which requires precise reconstruction of energies and time-dependent intensities of the OMC-related $γ$ rays. The setup also includes a veto counter system to allow selecting a clean sample of OMC events. This work provides a detailed description of the MONUMENT setup operated during the 2021 campaign, its two DAQ systems, calibration and analysis approaches, and summarises the achieved detector performance. Future improvements are also discussed.

nucl-ex↗

Electronic catalogue of muonic X-rays

{$μ$}X-ray spectra for Z=9-90 were measured with HPGe detectors and muonic beams of PSI (Villigen, Switzerland). The results are presented as electronic atlas composed of graphic plots. The atlas is available at JINR site.

nucl-ex↗