Optical Scintillation Imaging for Dynamic Source Tracking Dosimetry During Prostate HDR Brachytherapy

High-dose-rate (HDR) brachytherapy is highly conformal, but its accuracy depends on catheter and source placement, and clinical workflows lack real-time in vivo dosimetry (IVD) that verifies delivery without disrupting the procedure. We characterize a scintillator-based optical dosimeter integrated into a transrectal probe that tracks source position, speed, dose rate, and time-resolved cumulative dose. A 67 mm x 5 mm line scintillator is imaged by a CMOS camera through a 30-degree endoscopic lens; geometric and flat-field corrections remove barrel distortion and vignetting. Absolute dose was calibrated with a TOPAS Monte Carlo model of the probe's air-cavity geometry. The system was validated in a water phantom with an Ir-192 source and needles at radial offsets of 7, 10, and 15 mm. Response varied by $\pm$2\% along the 67 mm scintillator and was linear over 5-21 cGy/s ($R^2 \geq 0.995$). The Monte Carlo model showed a 3.75\% dose-rate reduction relative to TG-43 water-equivalent conditions. In phantom, the system resolved a 3 mm needle displacement, confirmed by CT. Measured dose-rate profiles agreed with Monte Carlo in peak magnitude and spatial distribution, and integral dose agreed within 1\%. By mapping dose directly to the measurement plane of a standard ultrasound transducer, this system provides high-resolution, time-resolved verification of HDR delivery and a clinical tool for detecting delivery errors with minimal changes to existing treatment protocols.

physics.med-ph↗

Quantitative real-time measurements of dose and dose rate in UHDR proton pencil beams via scintillation imaging system

Purpose: Ultra-fast scintillation imaging has been shown to provide a unique tool for spatio-temporal dosimetry of conventional cyclotron and synchrocyclotron pencil beam scanning (PBS) deliveries, indicating the potential use for characterization of ultra-UHDR PBS proton beams. The goal of this work is to introduce this novel concept and demonstrate its capabilities in recording complex dose rate maps at FLASH-capable proton beam currents, as compared to log-based dose rate calculation, internally developed UHDR beam simulation, and a fast point detector (EDGE diode). Methods: The light response of a scintillator sheet located at isocenter and irradiated by pencil beam scanning proton fields (40-210 nA, 250 MeV) was imaged by an ultra-fast iCMOS camera at 4.5-12 kHz sampling frequency. Image intensity was calibrated to dose with film and the recorded spatio-temporal data was compared to a PPC05 ion chamber, log-based reconstruction, and EDGE diode. Calculation of full-field mean and PBS dose rate maps were used to highlight the importance of high resolution, full-field information in UHDR studies. Results: Camera response was linear with dose (R2 = 0.997) and current (R2 = 0.98) in the range from 2-22 Gy and 40-210 nA, respectively, when compared to ion chamber readings. Planned and delivered spot positions agreed within 0.2+/-0.1 mm and total irradiation time agreed within 0.2+/-0.2 ms when compared with the log files, indicating the high concurrent spatial and temporal resolution. For all deliveries, the PBS dose rate measured at the diode location agreed between the imaging and the diode within 3+/-2% and with the simulation within 5+/-3%. Conclusion: The high linearity and various spatiotemporal metric reporting capabilities confirm the continued use of this camera system for UHDR beam characterization, especially for spatially resolved dose rate information.

physics.med-ph↗